Simultaneous Estimation of Ilaprazole and Domperidone in Pharmaceutical Dosage Form

Author(s):  
Gopi Patel ◽  
Kiral M Prajapati ◽  
Bhavesh Prajapati ◽  
Samir K Shah

A simple, accurate and precise stability-indicating RP-HPLC method was developed and subsequently validated for simultaneous determination of ilaprazole and domperidone in bulk and pharmaceutical dosage form. The proposed HPLC method utilizes  C18  (250 mm × 4.6 mm × 5 µm) column with mobile phase comprising of 0.5 % glacial acetic acid in water pH 5.5 adjusted with ammonia solution: methanol in the ratio 45:55 v/v at a flow rate of 1.0 ml/min. Quantitation was achieved with UV detection at 286 nm based on peak area with linear calibration curves at concentration  ranges 80-120µg/ml for ilaprazole and 240-360 µg/ml for domperidone  with correlation coefficient of 0.999.The retention times of ilaprazole and domperidone  were found to be 3.0 min, 5.4 min respectively. The mean recoveries obtained for ilaprazole and domperidone were found to be 99.76 ± 0.6463 % and 100.7 ± 0.2424 % respectively. Stress testing which covered acid, alkali hydrolysis, and peroxide, photolytic, thermal degradation was performed to prove the specificity of the proposed method and degradation was achieved. The proposed method was successfully applied for the stability indicating simultaneous estimation of ilaprazole and domperidone in routine quality control analysis in bulk and pharmaceutical formulation.

Author(s):  
Dhiraj Kumar ◽  
Susanta Kumar Panda ◽  
Sudhir Kumar Sahoo

A precise, accurate, economical and simple stability indicating RP-HPLC method was developed for the estimation of Amlodipine (AML) and Olmesartan (OLM) in bulk and pharmaceutical dosage form. Method was performed on a octadecyl silane column with dimensions 4.6 x 250 mm having particle size 5 micron. The mobile phase used in the method is TEA Buffer (pH 3.0) and acetonitrile in proportion of 25:75 respectively. The flow rate was maintained at 1.0 ml/ min and effluent was monitored at 258 nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The retention times were observed at 2.39 min and 3.33 min for AML and OLM respectively. The standard curve was found linear over a range of 05–35 μg/ml for AML and OLM. Similarly an average correlation coefficient was also obtained at 0.999 for AML and OLM. The limit of quantitation (LOQ) of this method was 2μg/ml for Amlodipine and Olmesartan. The absolute recovery was 100% for Amlodipine and 100.3 for Olmesartan. Degradation products produced as a result of stress studies did not interfere with the detection of AML and OLM and the assay can thus be considered stability-indicating.


2017 ◽  
Vol 9 (5) ◽  
pp. 1
Author(s):  
Shweta Mishra ◽  
C. J. Patel ◽  
M. M. Patel

Objective: This study aims to develop and validate a stability indicating HPLC method for simultaneous estimation of sacubitril and valsartan in pharmaceutical dosage form.Methods: Sacubitril and valsartan separation were achieved by LC-20 AT C18 (250 mm x 4.6 mm) column and buffer (potassium phosphate, pH 3.0): methanol (50:50) as mobile phase, at a flow rate of 1 ml/min (millilitre per minute). Detection was carried out at 224 nm (nanometer). The different HPLC experimental parameters were optimized and the method was validated according to the standard guideline. Forced degradation experiments were carried out by exposing sacubitril and valsartan standard and sample for thermal, photolytic, oxidative and acid-base hydrolytic stress conditions.Results: Retention time of sacubitril and valsartan were found to be 4.170 min (minute) and 6.530 min (minute) respectively. The method has been validated for linearity, accuracy, precision, LOD, and LOQ. Linearity observed for sacubitril is 12.25-36.75 μg/ml (microgram per milliliter) and for valsartan is 12.75-38.25 μg/ml (microgram per milliliter). The results showed that sacubitril and valsartan and the other degradation products were fully resolved and thus the proposed method is stability-indicating.Conclusion: The proposed HPLC method was found to be simple, specific, precise, accurate, rapid and economical for simultaneous estimation of valsartan and sacubitril in bulk and tablet dosage form. Thus the validated economical method was applied for forced degradation study of sacubitril and valsartan tablet.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (09) ◽  
pp. 53-59
Author(s):  
Girija Dandu ◽  
Basu Venkateswara Reddy

The present study describes the development and validation of a new stability indicating RP-HPLC method for simultaneous estimation of elbasvir and grazoprevir in bulk and pharmaceutical dosage form. The chromatographic separation was done by using reverse phase YMC column (4.6 x 250mm, 5μm).The mobile phase used was mixture of HPLC grade water acetonitrile (70:30V/V) at flow rate of 1ml/ min in isocratic mode and detection was carried out using PDA detector at 244nm.The developed method showed a good linearity in the range of 100-500μg/mL for elbasvir and 200-1000 μg/mL for grazoprevir with regression co-efficient of 0.999 for both the drugs. The % recovery of drugs was found to be 100.1% for elbasvir and 100.38% for grazoprevir. The proposed stability indicating method was accurate, precise, robust, stable and specific. The developed method was validated in accordance with ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document