scholarly journals STABILITY-INDICATING RP-HPLC METHOD FOR ANALYSIS OF EMTRICITABINE IN THE BULK DRUG AND IN A PHARMACEUTICAL DOSAGE FORM

2021 ◽  
Vol 10 (1) ◽  
pp. 78-86
Author(s):  
Vivek Jain ◽  
Pooja Prajapati ◽  
Prabhat Jain
2021 ◽  
Vol 001 (02) ◽  
Author(s):  
Shalin Parikh ◽  
Jayant Dave ◽  
Jayendrakumar Patel

A simple, precise, accurate and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for determination of Ketoconazole in bulk drug and pharmaceutical dosage form. Isocratic RP-HPLC separation was achieved on Agilent C8 (150 mm ?4.6 mm, 5 µm particle size) with the mobile phase 0.3 % Triaethylamine in 20 mM potassium dihydrogen phosphate buffer pH adjusted to 4.0: Acetonitrile (68:32 % v/v) at a flow rate 1.0 ml/min. The retention time of Ketoconazole was 8.97 ± 0.50 min. The method was validated for specificity, linearity, precision, accuracy and robustness. The linear regression analysis data of calibration curve showed good linearity in concentration range 10-60 ?g/ml. The Intraday and Interday precision were 0.59-1.11 % and 0.26-1.73 % RSD respectively. The accuracy was found to be 98.11-99.26 %. The drug was subjected to the stress conditions like hydrolysis, oxidation, photolysis and dry heat. The proposed method is found to be specific with respect to degradation product formed after Acidic hydrolysis, Oxidation, Thermal and Photolytic degradation. The Ketoconazole was found to be stable under neutral hydrolytic, thermal and photolytic stress conditions. Acidic, thermal, photolytic stress conditions showed degradation. The proposed chromatographic method can be used for estimation of drug during stress testing & formal stability studies.


Author(s):  
Y. Rajesh Babu ◽  
N. Appalaraju

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Imatinib mesylate in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Imatinib mesylate in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Imatinib mesylate in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


2009 ◽  
Vol 21 (4) ◽  
pp. 619-629 ◽  
Author(s):  
V. P. Rane ◽  
K. R. Patil ◽  
J. N. Sangshetti ◽  
R. D. Yeole ◽  
D. B. Shinde

Author(s):  
Rajesh Babu Y. ◽  
Appala Raju N.

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Pazopanib hydrochloride in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Pazopanib hydrochloride in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Pazopanib hydrochloride in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


2011 ◽  
Vol 34 (18) ◽  
pp. 2185-2195 ◽  
Author(s):  
Sharmistha Mohapatra ◽  
M. Mathrusri Annapurna ◽  
B. V. V. Ravi Kumar ◽  
Mohammed Anwar ◽  
Musarrat Husain Warsi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document