Visual Outcomes and Patient Satisfaction for Trifocal, Extended Depth of Focus and Monofocal Intraocular Lenses

2019 ◽  
Vol 35 (7) ◽  
pp. 434-440 ◽  
Author(s):  
Luba Rodov ◽  
Olga Reitblat ◽  
Adi Levy ◽  
Ehud I. Assia ◽  
Guy Kleinmann
2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Jae Hyuck Lee ◽  
Ho Seok Chung ◽  
Su Young Moon ◽  
So Young Park ◽  
Hun Lee ◽  
...  

Purpose. To evaluate the clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Setting. Asan Medical Center, Seoul, South Korea. Design. Prospective clinical study. Methods. Thirty-seven patients underwent TECNIS Symfony EDOF IOL (ZXR00) implantation in the dominant eye, and TECNIS +3.25 DMF IOL (ZLB00) implantation in the nondominant eye. Patients were followed up for 3 months; uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA), contrast sensitivity, defocus curves, stereopsis, and patient satisfaction were assessed. Results. At 3 months, the mean logarithm of the minimum angle of resolution (logMAR) of UDVA was 0.07 ± 0.09 in EDOF IOL eyes, 0.12 ± 0.11 in DMF IOL eyes, and 0.02 ± 0.05 in both eyes. UIVA was 0.11 ± 0.11 in EDOF IOL eyes, 0.16 ± 0.12 in DMF IOL eyes, and 0.04 ± 0.07 in both eyes. UNVA was 0.25 ± 0.15 in EDOF IOL eyes, 0.22 ± 0.16 in DMF IOL eyes, and 0.13 ± 0.13 in both eyes. Thirty patients (81.1%) were more than satisfied with near vision, and 8 patients (21.6%) complained of severe glare and halo. Spectacle independence for near vision was achieved in 34 patients (91.9%), and 31 patients (83.8%) had better than a 50-second arc of stereopsis. Conclusion. Mix-and-match cataract surgery with EDOF and DMF IOL implantation provided good visual outcomes for all distances. Additionally, excellent patient satisfaction was achieved with a high level of spectacle independence and acceptable photic phenomena.


Author(s):  
Jae Hyuck Lee ◽  
Ho Seok Chung ◽  
Su Young Moon ◽  
Hun Lee ◽  
Jae Yong Kim ◽  
...  

Purpose: To evaluate clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Methods: Thirty-seven patients received Tecnis Symfony EDOF IOL (ZXR00) implantation in the dominant eye, and Tecnis +3.25 DMF IOL (ZLB00) in the non-dominant eye. Patients were followed for 3 months, and uncorrected and corrected distance visual acuity (UDVA, CDVA) , uncorrected intermediate and near visual acuity (UIVA, UNVA), contrast sensitivity, defocus curves, stereopsis, and patient satisfaction were assessed. Results: At 3 months, mean logMAR UDVA was 0.07 ± 0.09 in EDOF IOL eyes, 0.12 ± 0.11 in DMF IOL eyes, and 0.02 ± 0.05 in both eyes. UIVA was 0.11 ± 0.11 in EDOF IOL eyes, 0.16 ± 0.12 in DMF IOL eyes, and 0.04 ± 0.07 in both eyes. UNVA was 0.25 ± 0.15 in EDOF IOL eyes, 0.22 ± 0.16 in DMF IOL eyes, and 0.13 ± 0.13 in both eyes. Thirty patients(81.1%) were more than satisfied with near vision, and 8 patients(21.6%) complained of severe glare and halo. Spectacle independence for near vision was achieved in 34 patients(91.9%), and 31 patients(83.8%) had better than a 50 second arc of stereopsis. Conclusion: Mix-and-match cataract surgery with EDOF and DMF IOL implantation provided good visual outcomes through all distances. Also excellent patient satisfaction was achieved with high level of spectacle independence and minimal photic phenomena.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Jie Xu ◽  
Tianyu Zheng ◽  
Yi Lu

Purpose. To compare the visual performance and astigmatism tolerance of 3 intraocular lens (IOL) groups: monofocal, bifocal, and extended depth-of-focus (EDOF) IOLs targeting slight myopia. Methods. Overall, there were 60 cataract surgery eyes from 60 patients with implantation of a monofocal, bifocal, or EDOF IOL (20 eyes in each IOL group). The EDOF IOLs targeted slight myopia (−0.25 D to −0.75 D). Intragroup comparison of visual acuity, defocus curve, objective optical quality, contrast sensitivity, visual function questionnaire scores, patients’ overall satisfaction, and the astigmatism tolerance was performed 3 months after surgery. Results. The EDOF group provided equivalently excellent distance visual outcomes (0.06 ± 0.12) as the monofocal (0.06 ± 0.09) and bifocal (0.03 ± 0.09) groups P = 0.554 , better intermediate vision than the other 2 groups P < 0.05 , and similarly satisfactory near visual outcomes (0.23 ± 0.16 at 20 cm, and 0.17 ± 0.14 at 33 cm) as the bifocal group (0.28 ± 0.14 at 20 cm and 0.08 ± 0.10 at 33 cm) P > 0.05 . The contrast sensitivity of EDOF IOL was slightly decreased compared to that of monofocal IOL, but it was better than that of bifocal IOL. The EDOF group showed significantly higher satisfaction than the bifocal group did when preoperative corneal astigmatism was 0.75 D or greater P = 0.009 . A significant negative correlation between the corneal astigmatism and patient satisfaction was observed in only the bifocal group. Conclusions. The EDOF IOLs targeting slight myopia offered satisfactory visual outcomes at an extended range from far to near distances. The EDOF and monofocal IOLs showed a better tolerance to astigmatism than did the bifocal IOL.


2021 ◽  
Vol 18 (3) ◽  
pp. 408-414
Author(s):  
К. B. Pershin ◽  
N. F. Pashinova ◽  
А. Yu. Tsygankov ◽  
E. A. Antonov

Aim. Analysis of the functional results of new IOL with an extended depth of focus implantation a in the short-term (6 months) follow-up period.Patients and methods. The prospective study included 27 patients (40 eyes) after bilateral (n = 12) or monolateral (n = 15) implantation of EDOF IOL Tecnis Symfony with an average follow-up period of 6.5 ± 0.2 (6–7) months. In all cases, IOL implantation was preceded by cataract phacoemulsification or removal of the transparent lens for refractive purposes. The age range was from 39 to 78 (60.6 ± 10.1) years. EDOF IOL Tecnis Symfony ZXR00 was implanted in 30 eyes, and toric EDOF IOL Tecnis Symfony ZXT100, ZXT150, ZTX225, and ZXT300 were implanted in 10 eyes in the presence of clinically significant astigmatism.Results. An increase in UCNVA from 0.18 ± 0.04 to 0.79 ± 0.11, UCIVA from 0.21 ± 0.07 to 0.89 ± 0.10, UCDVA from 0.24 ± 0.06 to 0.95 ± 0.16, BCNVA from 0.61 ± 0.05 to 0.80 ± 0.03, BCIVA from 0.58 ± 0.10 to 0.97 ± 0.19, and BCDVA from 0.65 ± 0.08 to 1.0 ± 0.06 (p < 0.05 in all cases). The spherical equivalent of refraction decreased from –4.5 ± 1.8 in the preoperative period to –0.18 ± 0.92 in the follow-up period of 6 months after implantation of the Tecnis Symfony ZXR00 IOL. In the group with toric IOLs, a decrease in the cylindrical component of refraction was shown from 1.33 ± 1.02 (modulo) to 0.61 ± 0.44 (modulo) during the maximum observation period. In all cases, the rotational stability of the implanted IOLs was noted. In 9 patients out of 24 (37.5 %), permanent or periodic optical phenomena were detected, of which 4 patients (16.7 %) had halos, 3 (12.5 %) had glare, and 2 (8.3 %) had difficulty driving in the dark. These side effects did not affect the overall patient satisfaction — 22 patients (91.7 %) rated the result of the operation as “excellent”, and 2 patients (8.3 %) — as “good”.Conclusion. The paper presents an analysis of the first experience in the Russian Federation of implantation of new IOLs with extended depth of focus and their toric version in 27 patients. Data on the effectiveness of this IOL for vision correction at all distances, low frequency of side optical phenomena, and high patient satisfaction are presented. Further comparative studies with other multifocal IOLs are needed.


2019 ◽  
Author(s):  
Jie Xu ◽  
Tianyu Zheng ◽  
Yi Lu

Abstract BackgroundTo compare the visual performance and astigmatism tolerance of 3 intraocular lens (IOLs): monofocal, bifocal, and extended depth-of-focus (EDOF) IOLs targeting slight myopia.MethodsOverall, there were 60 cataract surgery eyes from 60 patients with implantation of a monofocal, bifocal or EDOF IOL (20 eyes in each IOL group). The EDOF IOLs targeted slight myopia (-0.25 D to -0.75 D). Intragroup comparison of visual acuity, defocus curve, objective optical quality, contrast sensitivity, Visual function questionnaire scores, patients’ overall satisfaction, and the astigmatism tolerance were performed 3 months after surgery.ResultsThe EDOF group provided equivalently excellent distance visual outcomes (0.06±0.12) as the monofocal (0.06±0.09) and bifocal (0.03±0.09) groups (P=0.554), better intermediate vision than the other 2 groups (P<0.05), and similarly satisfactory near visual outcomes (0.23±0.16 at 20 cm, and 0.17±0.14 at 33 cm) as the bifocal group (0.28±0.14 at 20 cm, and 0.08±0.10 at 33 cm) (P>0.05). The contrast sensitivity of EDOF IOL was slightly decreased compared to that of monofocal IOL, but it was better than that of bifocal IOL. The EDOF group showed significantly higher satisfaction than the bifocal group did when preoperative corneal astigmatism was 0.75 D or greater (P=0.009). A significant negative correlation between the corneal astigmatism and patient satisfaction was observed in only the bifocal group. ConclusionsThe EDOF IOLs targeting slight myopia offered satisfactory visual outcomes at an extended range from far to near distances. The EDOF and monofocal IOLs showed a better tolerance to astigmatism than did the bifocal IOL.


Author(s):  
K.B. Pershin ◽  
◽  
N.F. Pashinova ◽  
А.I. Tsygankov ◽  
E.A. Antonov ◽  
...  

Purpose. Analysis of the functional results of new IOL with an extended depth of focus implantation a in the short-term (6 months) follow-up period. Material and methods. The prospective study included 27 patients (40 eyes) after bilateral (n=12) or monolateral (n=15) implantation of EDOF IOL Tecnis Symfony with an average follow-up period of 6.5±0.2 (6-7) months. In all cases, IOL implantation was preceded by cataract phacoemulsification or removal of the transparent lens for refractive purposes. The age range was from 39 to 78 (60.6±10.1) years. EDOF IOL Tecnis Symfony ZXR00 was implanted in 30 eyes, and toric EDOF IOL Tecnis Symfony ZXT100, ZXT150, ZTX225, and ZXT300 were implanted in 10 eyes in the presence of clinically significant astigmatism. Results. An increase in UCNVA from 0.18±0.04 to 0.79±0.11, UCIVA from 0.21±0.07 to 0.89±0.10, UCDVA from 0.24±0.06 to 0.95±0.16, BCNVA from 0.61±0.05 to 0.80±0.03, BCIVA from 0.58±0.10 to 0.97±0.19, and BCDVA from 0.65±0.08 to 1.0±0.06 (p<0.05 in all cases). The spherical equivalent of refraction decreased from -4.5±1.8 in the preoperative period to -0.18±0.92 in the follow-up period of 6 months after implantation of the Tecnis Symfony ZXR00 IOL. In the group with toric IOLs, a decrease in the cylindrical component of refraction was shown from 1.33±1.02 (modulo) to 0.61±0.44 (modulo) during the maximum observation period. In all cases, the rotational stability of the implanted IOLs was noted. In 9 patients out of 24 (37.5%), permanent or periodic optical phenomena were detected, of which 4 patients (16.7%) had halos, 3 (12.5%) had glare, and 2 (8.3%) had difficulty driving in the dark. These side effects did not affect the overall patient satisfaction – 22 patients (91.7%) rated the result of the operation as "excellent", and 2 patients (8.3%) – as "good". Conclusion. The paper presents an analysis of the first experience in the Russian Federation of implantation of new multifocal and toric IOLs with extended depth of focus in 27 patients. Data on the effectiveness of this IOL for vision correction at all distances, low frequency of side optical phenomena, and high patient satisfaction are presented. Further comparative studies with other multifocal IOLs are needed. Key words: cataract; presbyopia; multifocal IOL; IOL with extended depth of focus; EDOF; Symphony.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yueyang Zhong ◽  
Kai Wang ◽  
Xiaoning Yu ◽  
Xin Liu ◽  
Ke Yao

AbstractThis meta-analysis aimed to evaluate the clinical outcomes following implantation of trifocal intraocular lenses (IOLs) or a hybrid multifocal-extended depth of focus (EDOF) IOL in cataract or refractive lens exchange surgeries. We examined 13 comparative studies with bilateral implantation of trifocal (898 eyes) or hybrid multifocal-EDOF (624 eyes) IOLs published through 1 March 2020. Better uncorrected and corrected near visual acuity (VA) were observed in the trifocal group (MD: − 0.143, 95% CI: − 0.192 to − 0.010, P < 0.001 and MD: − 0.149, 95% CI: − 0.217 to − 0.082, P < 0.001, respectively), while the hybrid multifocal-EDOF group presented better uncorrected intermediate VA (MD: 0.055, 95% CI: 0.016 to 0.093, P = 0.005). Trifocal IOLs were more likely to achieve spectacle independence at near distance (RR: 1.103, 95% CI: 1.036 to 1.152, P = 0.002). The halo photic effect was generated more frequently by the trifocal IOLs (RR: 1.318, 95% CI: 1.025 to 1.696, P = 0.031). Contrast sensitivity and subjective visual quality yielded comparable results between groups. Trifocal IOLs demonstrated better performance at near distance but apparently led to more photic disturbances. Our findings provided the most up-to-date and comprehensive evidence by comparing the benefits of advanced IOLs in clinical practice.


Sign in / Sign up

Export Citation Format

Share Document