scholarly journals Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic

2020 ◽  
Vol 36 (8) ◽  
pp. 520-527 ◽  
Author(s):  
Aixa Alarcon ◽  
Carmen Cánovas ◽  
Bram Koopman ◽  
Henk Weeber ◽  
Gerd U. Auffarth ◽  
...  
2007 ◽  
Vol 48 (4) ◽  
pp. 627 ◽  
Author(s):  
Chang Yeom Kim ◽  
So-Hyang Chung ◽  
Tae-im Kim ◽  
Young Jae Cho ◽  
Geunyoung Yoon ◽  
...  

2015 ◽  
Vol 99 (12) ◽  
pp. 1732-1738 ◽  
Author(s):  
Naoko Matsuki ◽  
Makoto Inoue ◽  
Yuji Itoh ◽  
Toshiyuki Nagamoto ◽  
Akito Hirakata

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Grzegorz Łabuz ◽  
Timur M. Yildirim ◽  
Gerd U. Auffarth ◽  
Hyeck-Soo Son ◽  
Ramin Khoramnia

Abstract Background Intraocular lens (IOL) calcification is a serious condition that can only be treated by removing the clouded lens. Since explantation bears the risk of complications, it is often deferred until the patient finds the symptoms intolerable. Usually, as the IOL opacifies, visual acuity is minimally affected early on. In this study, we assessed the impact of IOL opacification on optical quality. Methods We analyzed ten opacified explanted IOLs (Oculentis GmbH). Wavefront aberrations were obtained with a SHSOphthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor. The root mean square (RMS) of higher-order aberrations (HOAs) was compared. The effect of calcification on image quality was assessed through the Strehl ratio (SR). We detected light scattering with a C-Quant (Oculus GmbH) and expressed it as a straylight parameter. Results At 2 mm, 3 mm and 4 mm, the mean RMS (±standard deviation) was 0.033 μm (±0.026 μm), 0.044 μm (±0.027), and 0.087 μm (±0.049), respectively. The mean SR value was 0.81 ± 0.15 at 3 mm, with four IOLs showing a nearly diffraction-limited performance, but in two explants, opacification precluded reliable measurements. Increased straylight was found in all opacified IOLs with a mean value of 150.2 ± 56.3 deg2/sr at 3 mm. Conclusions We demonstrated that IOL opacification induces HOAs. However, the RMS remained low, which resulted only in a slight reduction of the SR-derived optical quality. On the other hand, we found a severe straylight elevation in the opacified lenses, which may result in dysphotopsia, such as glare, and subjective complaints, despite good visual acuity.


Author(s):  
B. de Luis Eguileor ◽  
L. Martínez-Indart ◽  
N. Martínez Alday ◽  
C. Sacristán Egüén ◽  
C. Cuadros Sánchez

Sign in / Sign up

Export Citation Format

Share Document