intermediate vision
Recently Published Documents


TOTAL DOCUMENTS

23
(FIVE YEARS 15)

H-INDEX

5
(FIVE YEARS 2)

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jungah Huh ◽  
Youngsub Eom ◽  
Seul Ki Yang ◽  
Young Choi ◽  
Hyo Myung Kim ◽  
...  

Abstract Background To compare clinical outcomes and optical performance of a new monofocal with enhanced intermediate function intraocular lenses (IOLs) with that of conventional monofocal IOLs. Methods Sixty eyes of 30 patients who underwent phacoemulsification with bilateral implantation of the ICB00 (15 patients) or ZCB00 (15 patients) IOLs were enrolled. Binocular corrected distance visual acuity (CDVA), distance corrected near visual acuity (DCNVA), and distance corrected intermediate visual acuity (DCIVA) were measured at 4 weeks after surgery. Patient satisfaction for overall, near, intermediate, and distance vision were assessed. The binocular defocus curves were measured. The root mean square of modulation transfer function (MTFRMS) was measured in the optical bench study. Results The mean binocular DCIVA was significantly better in the ICB00 group (0.01 logMAR) compared to the ZCB00 group (0.13 logMAR), but CDVA and DCNVA were not. The patient satisfaction for near and intermediate vision was significantly higher in the ICB00 group compared to the ZCB00. However, there was no difference in patient satisfaction for overall and distance vision between two groups. The defocus curves showed that mean visual acuity of the ICB00 group was significantly better than that of the ZCB00 group at between − 1.00 D to − 3.00 D of defocus. The ICB00 IOL had higher MTFRMS values at between − 0.50 D to − 2.00 D of defocus compared to the ZCB00 IOL. Conclusions The ICB00 IOL provides better binocular intermediate vision and higher satisfaction for near and intermediate vision than the ZCB00 IOL while maintaining excellent distance vision.


2021 ◽  
pp. 112067212110183
Author(s):  
Daniele Tognetto ◽  
Rosa Giglio ◽  
Chiara De Giacinto ◽  
Carmen Dell’Aquila ◽  
Giulia Pian ◽  
...  

Purpose: Implementation of the International Consortium for Health Outcomes Measurements (ICHOM) standard for cataract surgery into clinical practice at an Italian tertiary referral centre. Methods: Prospective, observational, descriptive study consisting of the registry and analysis of cataract surgeries performed during a 6-month enrolment period at the University Eye Clinic of Trieste, Trieste, Italy. Outcomes were recorded and analysed according to the ICHOM Cataract Standard Set version 2.0.1. Records included clinician-reported outcome measures (CROMs) – visual outcome and complications – and patient-reported outcome measures (PROMs) – self-assessed vision with the Catquest-9SF questionnaire. Correlations between PROMs and CROMs were evaluated. A multiple linear regression was used for predicting the change in PROMs with surgery. Results: A total of 218 eyes (of 218 patients) were analysed. Postoperative corrected distance visual acuity (CDVA) was ⩾0.3 in 89.0% (194/218) of eyes. There was a statistically significant improvement of the post-operative Catquest-9SF global average score. ( p < 0.001). The change in the Catquest-9SF score significantly correlated with the change in Item 2 score (related to intermediate vision) ( r = 0.634, p < 0.001). A predictive model of the change in the Catquest-9SF score was found ( p < 0.001, R2: 0.527) based on preoperative Catquest-9SF total score, presence or not of macular degeneration, presence or not of intraoperative complications, age >75 years old, and preoperative CDVA. Conclusions: Cataract surgery improves the functional vision, with some factors limiting the outcomes such as comorbidities. Self-perceived improvement in intermediate vision significantly influenced the improvement in self-assessed vision.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hyeck-Soo Son ◽  
Grzegorz Łabuz ◽  
Ramin Khoramnia ◽  
Timur M. Yildirim ◽  
Gerd U. Auffarth

Abstract Background To assess the optical behavior of a new diffractive intraocular lens (IOL) and compare its performance to that of an established extended-depth-of-focus (EDOF) IOL. Methods This study assessed the Proming EDOF Multifocal AM2UX [Eyebright Medical Technology (Beijing) Co., Ltd., China] and the AT LARA 829MP [Carl Zeiss Meditec, Germany]. An experimental set-up with 0.01% fluorescein solution and monochromatic light (532 nm) was used to visualize the IOLs’ ray propagation. In addition, the optical quality of the IOLs was assessed by measuring the modulation transfer function (MTF) values at 50lp/mm and 3.0 and 4.5 mm apertures on the optical bench OptiSpheric® IOL PRO II [Trioptics GmbH, Germany]. Results The ray propagation of the two IOLs showed two distinct foci. Light intensity assessment revealed that both IOLs allocate more energy to primary than secondary focus. At 3.0 mm pupil, the MTF values at 50lp/mm for the primary focus were 0.39 and 0.37, and for the secondary focus, 0.29 and 0.26 for the AT LARA and Proming IOLs, respectively. At 4.5 mm pupil, the single-frequency MTF for the primary focus was 0.51 and 0.24 and for the secondary focus 0.21 and 0.15 for the AT LARA and Proming IOLs, respectively. Conclusions When tested with an aberration-free model cornea under monochromatic conditions, the Proming behaved as a low-add bifocal lens; however, its properties did not differ much from the well-established AT LARA EDOF IOL. The AT LARA outperformed the Proming at low defocus (up to 2D), while the latter demonstrated better image quality in the 2-3D range.


2021 ◽  
Author(s):  
Hyeck-Soo Son ◽  
Grzegorz Łabuz ◽  
Ramin Khoramnia ◽  
Timur M. Yildirim ◽  
Gerd U. Auffarth

Abstract BackgroundTo assess the optical behavior of a new diffractive intraocular lens (IOL) and compare its performance to that of an established extended-depth-of-focus (EDOF) IOL.MethodsThis study assessed the Proming EDOF Multifocal AM2UX [Eyebright Medical Technology (Beijing) Co., Ltd., China] and the AT LARA 829MP [Carl Zeiss Meditec, Germany]. An experimental set-up with 0.01% fluorescein solution and monochromatic light (532nm) was used to visualize the IOLs’ ray propagation. In addition, the optical quality of the IOLs was assessed by measuring the modulation transfer function (MTF) values at 50lp/mm and 3.0 and 4.5mm apertures on the optical bench OptiSpheric® IOL PRO II [Trioptics GmbH, Germany]. ResultsThe ray propagation of the two IOLs showed two distinct foci. Light intensity assessment revealed that both IOLs allocate more energy to primary than secondary focus. At 3.0mm pupil, the MTF values at 50lp/mm for the primary focus were 0.39 and 0.37, and for the secondary focus, 0.29 and 0.26 for the AT LARA and Proming IOLs, respectively. At 4.5mm pupil, the single-frequency MTF for the primary focus was 0.51 and 0.24 and for the secondary focus 0.21 and 0.15 for the AT LARA and Proming IOLs, respectively.ConclusionsFrom the optical point of view, the Proming behaved as a low-add bifocal lens; however, its properties did not differ much from the well-established AT LARA EDOF IOL. The AT LARA outperformed the Proming at low defocus (up to 2D), while the latter demonstrated better image quality in the 2-3D range.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Tetsuro Oshika ◽  
Kazuno Negishi ◽  
Toru Noda ◽  
Hiroyuki Arai ◽  
Mikio Inamura ◽  
...  

Abstract Background To prospectively evaluate surgical results following implantation of rotationally asymmetric, plate-haptic, refractive segmented multifocal toric intraocular lenses (IOLs) with near addition of + 1.5 diopters (D) (Lentis Comfort LS-313 MF15T, Oculentis GmbH). Methods In 59 eyes of 41 patients, ocular examinations were conducted before and 1 day, 1 week, 1, 3, and 6 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were tested. A defocus curve was drawn, and the degree of disturbing photic phenomena were questioned. Results The IOL showed excellent rotational stability; the average absolute rotation was 1.66 ± 1.17 degrees from 1 day 1 to 6 months postoperatively, and 98.1 and 100% of eyes yielded rotation of less than 5 and 10 degrees, respectively. Postoperative distance and intermediate visual acuity were highly satisfactory; UDVA, CDVA, UIVA, and DCIVA were about 20/20, 20/16, 20/25, 20/25, respectively. Near visual acuity was suboptimal; UNVA and DCNVA were at approximately 20/60. The defocus curve analysis showed that 20/25 and 20/40 uncorrected visual acuity was attained at as close as 60 and 40 cm, respectively. Contrast sensitivity was within a normal range, and subjective photic phenomena were minimum. Conclusions The refractive segmented, rotationally asymmetric multifocal toric IOLs with + 1.5 D near addition showed superb rotational stability and highly satisfactory distance and intermediate vision. Contrast sensitivity was high and incidence of photic symptoms was very low. Trial registration This study was registered at JAPIC Clinical Trials Information, ID: JapicCTI-183,877, https://www.clinicaltrials.jp/cti-user/trial/Search.jsp (February 5, 2018).


Author(s):  
B. de Luis Eguileor ◽  
L. Martínez-Indart ◽  
N. Martínez Alday ◽  
C. Sacristán Egüén ◽  
C. Cuadros Sánchez

2020 ◽  
Vol 36 (8) ◽  
pp. 520-527 ◽  
Author(s):  
Aixa Alarcon ◽  
Carmen Cánovas ◽  
Bram Koopman ◽  
Henk Weeber ◽  
Gerd U. Auffarth ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Masayuki Ouchi ◽  
Takuya Shiba

Purpose. To evaluate the clinical outcome of blended vision combined with micromonovision (MMBV) using a + 4 diopter (D) addition power (add) diffractive intraocular lens (MIOL) and a + 2.75 D add MIOL with a myopic target of −0.5 D. Methods. One hundred twenty eyes of 60 cases were enrolled. The +4 D add MIOLs were placed in the nondominant eye, the +2.75 D add MIOLs were placed in the dominant eye with a myopic target of −0.5 D in 30 cases (the MMBV group), and the +4 D add MIOLs were placed in both eyes in another 30 cases (controls). Postoperative clinical outcomes were compared between the two groups. Results. Compared with the controls, binocular uncorrected intermediate vision at 70 cm was significantly better in the MMBV group (p=0.02). Contrast sensitivity at 12 cycles per degree and the 6% and 12.5% low-contrast visual acuities were also significantly better in the MMBV group compared with the controls (p values = 0.05, 0.05, and 0.04, respectively). Uncorrected and corrected distance and near VA did not differ significantly between the two groups. Conclusion. MMBV provided a better intermediate VA, contrast sensitivity, and low-contrast VA than bilateral implantation of the +4 D add MIOL, while preserving comparable near and distance vision.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Daniele Tognetto ◽  
Paolo Cecchini ◽  
Rosa Giglio ◽  
Gianluca Turco

Sign in / Sign up

Export Citation Format

Share Document