Dosimetric Comparisons of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, Tomotherapy, Stereotactic Radiosurgery, and Proton Therapy for Treatment of Patients with a Vestibular Schwannoma

2019 ◽  
Vol 74 (4) ◽  
pp. 389-398
Author(s):  
Yoonjin Oh ◽  
Dong Oh Shin ◽  
Moonkyoo Kong ◽  
Dong Ho Shin ◽  
Weon Kuu Chung ◽  
...  
2014 ◽  
Vol 2014 ◽  
pp. 1-5
Author(s):  
Vincent Wing Cheung Wu ◽  
Man In Pun ◽  
Cho Pan Lam ◽  
To Wing Mok ◽  
Wah Wai Mok

This study compared the performance of volumetric modulated arc therapy (VMAT) techniques: single arc volumetric modulated arc therapy (SA-VMAT) and double arc volumetric modulated arc therapy (DA-VMAT) with the static beam conventional intensity modulated radiotherapy (C-IMRT) for non-small-cell lung carcinoma (NSCLC). Twelve stage I and II NSCLC patients were recruited and their planning CT with contoured planning target volume (PTV) and organs at risk (OARs) was used for planning. Using the same dose constraints and planning objectives, the C-IMRT, SA-VMAT, and DA-VMAT plans were optimized. C-IMRT consisted of 7 static beams, while SA-VMAT and DA-VMAT plans consisted of one and two full gantry rotations, respectively. No significant difference was found among the three techniques in target homogeneity and conformity. Mean lung dose in C-IMRT plan was significantly lower than that in DA-VMAT plan P=0.04. The ability of OAR sparing was similar among the three techniques, with no significant difference in V20, V10, or V5 of normal lungs, spinal cord, and heart. Less MUs were required in SA-VMAT and DA-VMAT. Besides, SA-VMAT required the shortest beam on time among the three techniques. In treatment of early stage NSCLC, no significant dosimetric superiority was shown by the VMAT techniques over C-IMRT and DA-VMAT over SA-VMAT.


2017 ◽  
Vol 16 (3) ◽  
pp. 272-279
Author(s):  
Steven B. D. Murphy ◽  
Heather Drury-Smith

AbstractBackground and purposeTo determine which concomitant boost technique is dosimetrically superior in the treatment of breast cancer; volumetric-modulated arc therapy (VMAT) or fixed field intensity-modulated radiotherapy (ff-IMRT).Materials and methodsIn total, 30 breast patients were re-planned with both VMAT and fixed field concomitant boost intensity-modulated radiotherapy techniques. A hybrid technique was used delivering 80% of the dose through tangential beams and 20% through an integrated boost. A two-tailed t-test sample for means was used to compare the dosimetric differences between the techniques.ResultsMaximum dose was statistically lower for VMAT; 103·2 versus 103·7% for ff-IMRT along with statistically lower V2 Gy doses to the contralateral lung (0·7 versus 1·6%) and heart for both left- (19·0%/22·6%), and right- (5·5%/8·8%) sided patients, respectively. ff-IMRT boasted significantly lower ipsilateral lung V20, V18 and V10 Gy (7·9/8·6/13·1 versus 8·1/8·8/13·4%) than VMAT, respectively. No differences were found with minimum coverage, mean dose and V5 Gy to all organs at risk (OARs).ConclusionVMAT and ff-IMRT techniques demonstrate excellent target coverage and OAR sparing facilitated by the hybrid planning technique and deep inspiration breath hold. There is no obvious dosimetrically superior option between the two techniques. Reduced treatment times with VMAT make it more desirable to implement clinically.


Sign in / Sign up

Export Citation Format

Share Document