Aspects of Extremely Low Frequency Electric and Magnetic Cleanliness on Space Platforms

Author(s):  
Alexandra P. Mavropoulou ◽  
Alexandros D. Bechrakis Triantafyllos ◽  
Christos D. Nikolopoulos

Nowadays, a wide range of space missions accommodate ever-stricter electromagnetic cleanliness requirements arising either from the need for more precise measurements or from the implementation of highly sensitive equipment. Therefore, the establishment of a methodology that ensures the minimization of the electric and/or magnetic field in specific areas inside or outside the spacecraft structure is crucial. Towards this goal, the current chapter proposes that utilizing the results of a process completed during the early design stages of a mission, that is, the measurement and characterization of each implemented device, the desired elimination of the field can be achieved. In particular, the emerged electromagnetic signatures of the units are proven essential for the proposed methodology, which, using a heuristic approach, defines the optimal ordinance of the equipment that leads to system-level electromagnetic field minimization in the volume of interest. The dimensions of the devices and the effect of the conductive surfaces of the spacecraft's hull are also taken into account.

Author(s):  
Christos D. Nikolopoulos

Nowadays, a wide range of space missions accommodate ever-stricter electromagnetic cleanliness requirements arising either from the need for more precise measurements or from the implementation of highly sensitive equipment. Therefore, the establishment of a methodology that ensures the minimization of the electric and/or magnetic field in specific areas inside or outside the spacecraft structure is crucial. Towards this goal, the current chapter proposes that utilizing the results of a process completed during the early design stages of a mission, that is, the measurement and characterization of each implemented device, the desired elimination of the field can be achieved. In particular, the emerged electromagnetic signatures of the units are proven essential for the proposed methodology, which, using a heuristic approach, defines the optimal ordinance of the equipment that leads to system-level electromagnetic field minimization in the volume of interest. The dimensions of the devices and the effect of the conductive surfaces of the spacecraft's hull are also taken into account.


1998 ◽  
Vol 13 (11) ◽  
pp. 776-781
Author(s):  
Amy Schiffman ◽  
Patrick N. Breysse ◽  
Sukon Kanchanaraksa ◽  
Terry Cutler ◽  
Victor Fan

2009 ◽  
Vol 111 (2) ◽  
pp. 275-278 ◽  
Author(s):  
Jang Ho Roh ◽  
Deok Won Kim ◽  
Sung Jin Lee ◽  
Ji Young Kim ◽  
Sung Won Na ◽  
...  

Background Numerous electronic devices have been introduced into operating rooms. Although little is known about the relationship between exposure to electromagnetic fields and health hazards, several studies have demonstrated causal relationships between electromagnetic fields exposure and various symptoms, cancers, and other diseases. Methods This study was approved by the Institutional Review Board. The intensity of extremely low-frequency electromagnetic fields was measured during surgery with the extremely low-frequency electromagnetic field strength measurement system at the standing position of anesthesiologists in 18 operating rooms and analyzed with EMDEX analysis and graphical program (EMCALC 95; ENERTECH, Campbell, CA). Results The average measurement duration per operating room per day was 7.41 +/- 0.70 h (mean +/- SD). The average sample number of measurements was 888.11 +/- 82.75 per operating room. The average magnetic field was 5.83 +/- 5.23 milliGuass (mG) (range, 0.10-33.80 mG), with 70% of these levels 2 mG or greater. Conclusions The authors' results indicate that anesthesiologists in operating rooms are exposed to extremely low-frequency electromagnetic field levels that exceed magnetic field intensity of 2 mG recommended by the Swedish Board for Technical Accreditation for production by computer monitors and detected 30 cm from them. It currently is not clear if this exposure has health effects on anesthesiologists and other operating room personnel.


Sign in / Sign up

Export Citation Format

Share Document