scholarly journals Hybrid Therapy of Class III Antiarrhythmic Drugs and Extensive Encircling Pulmonary Vein Isolation in Patient with Drug Resistant Very Long-Lasting Atrial Fibrillation

2011 ◽  
Vol 27 (Supplement) ◽  
pp. YIAC_2
Author(s):  
Masatsugu Ohe ◽  
Masahiko Goya ◽  
Kenichi Hiroshima ◽  
Kentaro Hayashi ◽  
Yu Makihara ◽  
...  
Author(s):  
Hui-Nam Pak ◽  
Je-Wook Park ◽  
Song-Yi Yang ◽  
Tae-Hoon Kim ◽  
Jae-Sun Uhm ◽  
...  

Background: The efficacy of cryoballoon pulmonary vein isolation (Cryo-PVI) is equivalent to that of radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation (AF). We aimed to compare the efficacy and safety profile of Cryo-PVI and high-power, short-duration (HPSD) radiofrequency catheter ablation (RFCA) in patients with AF. Methods: We prospectively randomized 314 patients with paroxysmal AF (men, 71.3%; 59.9±10.9 years old) to either the Cryo-PVI group (n=156) or HPSD-RFCA group (n=158). Cavotricuspid isthmus ablation and linear ablation from the superior vena cava to the right atrial septum in addition to pulmonary vein isolation were carried out in the majority of patients in the HPSD-RFCA group. The primary end point was AF recurrence after a single procedure; secondary end points were the recurrence pattern, cardioversion rate, follow-up heart rate variability, and response to antiarrhythmic drugs. Results: After a mean follow-up of 9.8±5.1 months, the clinical recurrence rate did not significantly differ between the two groups (log-rank P =0.840). The rate of recurrence as atrial tachycardia ( P >0.999), cardioversion ( P =0.999), and 3-month heart rate variability (high frequency; P =0.506) did not significantly differ. During the final follow-up, sinus rhythm was maintained without antiarrhythmic drugs in 70.5% of the Cryo-PVI group and 73.4% of the HPSD-RFCA group ( P =0.567). No significant difference was found in the major complication rate between the two groups (3.8% versus 0.6%; P =0.066), but total procedure time was significantly shorter in the Cryo-PVI group (78.5±20.2 versus 124.5±37.1 minutes; P <0.001). Conclusions: In patients with paroxysmal AF, the Cryo-PVI is an effective rhythm-control strategy with a shorter procedure time compared with the HPSD-RFCA. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03920917.


2005 ◽  
Vol 69 (12) ◽  
pp. 1503-1507 ◽  
Author(s):  
Hideaki Tojo ◽  
Koichiro Kumagai ◽  
Hiroo Noguchi ◽  
Masahiro Ogawa ◽  
Tomoo Yasuda ◽  
...  

2020 ◽  
Vol 13 (10) ◽  
Author(s):  
Shohreh Honarbakhsh ◽  
Richard J. Schilling ◽  
Malcolm Finlay ◽  
Emily Keating ◽  
Ross J. Hunter

Background: A novel stochastic trajectory analysis of ranked signals (STAR) mapping approach to guide atrial fibrillation (AF) ablation using basket catheters recently showed high rates of AF termination and subsequent freedom from AF. Methods: This study aimed to determine whether STAR mapping using sequential recordings from conventional pulmonary vein mapping catheters could achieve similar results. Patients with persistent AF<2 years were included. Following pulmonary vein isolation AF drivers (AFDs) were identified on sequential STAR maps created with PentaRay, IntellaMap Orion, or Advisor HD Grid catheters. Patients had a minimum of 10 multipolar recordings of 30 seconds each. These were processed in real-time and AFDs were targeted with ablation. An ablation response was defined as AF termination or cycle length slowing ≥30 ms. Results: Thirty patients were included (62.4±7.8 years old, AF duration 14.1±4.3 months) of which 3 had AF terminated on pulmonary vein isolation, leaving 27 patients that underwent STAR-guided AFD ablation. Eighty-three potential AFDs were identified (3.1±1.1 per patient) of which 70 were targeted with ablation (2.6±1.2 per patient). An ablation response was seen at 54 AFDs (77.1% of AFDs; 21 AF termination and 33 cycle length slowing) and occurred in all 27 patients. No complications occurred. At 17.3±10.1 months, 22 out of 27 (81.5%) patients undergoing STAR-guided ablation were free from AF/atrial tachycardia off antiarrhythmic drugs. Conclusions: STAR-guided AFD ablation through sequential mapping with a multipolar catheter effectively achieved an ablation response in all patients. AF terminated in a majority of patients, with a high freedom from AF/atrial tachycardia off antiarrhythmic drugs at long-term follow-up. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02950844.


2011 ◽  
Vol 27 (Supplement) ◽  
pp. JHJS_3
Author(s):  
Masahiko Goya ◽  
Kenichi Hiroshima ◽  
Masatsugu Ohe ◽  
Kentaro Hayashi ◽  
Yu Makihara ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document