Analysis and Control of the Closed-Loop Current Based on Power Flow Calculation in Distribution Network

2013 ◽  
Vol 373-375 ◽  
pp. 1353-1356
Author(s):  
Bao Li Gui ◽  
Jin Ling Lu ◽  
Qing Jie Zhou ◽  
Ren Min Gong

With the development of our country electric power enterprise, closed-loop pour load operation has become increasingly frequent in power distribution network, the resulting circulation problems affect the safe operation of power grid. The calculation method of system is used by BX type solution fast decomposition method and it is very suitable for distribution integration, by the method we can calculate the steady state current and transient current of closed-loop. It also provide accurate current analysis and control. With analysis of examples, finally indicates that the method can offer good for dispatch staff for closed-loop operation decision support, and it has a certain guiding significance.

Open Physics ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 1094-1106 ◽  
Author(s):  
Zhen Li ◽  
Yao Zhang ◽  
Muhammad Aqeel Ashraf

Abstract Distribution network reconfiguration is a very complex and large-scale combinatorial optimization problem. In network reconfiguration, whether an effective solution can be obtained is a key issue. Aiming at the problems in network reconstruction by traditional algorithm, such as long time required, more times of power flow calculation and high network loss, a network optimization design algorithm based on improved ant colony algorithm for high voltage power distribution network is proposed. After analyzing the operating characteristics of the high voltage power distribution network, the network topology of the high voltage power distribution network is described by constructing a hierarchical variable-structure distribution network model. A mathematical model of distribution network reconstruction considering the opportunity constraint with the minimum network loss as the objective function is established. The power flow distribution is calculated by using the pre-push back-generation method combined with the hierarchical structure of the distribution network. The maximum and minimum ant colony algorithm is introduced to improve the pheromone updating method of the traditional ant colony algorithm, and the search range is expanded, so that the algorithm can jump out of the local optimization trap to realize the accurate solution of the power distribution network reconstruction model. The experimental results show that compared with the current network reconstruction algorithm, the proposed algorithm requires less time for convergence, less power flow calculation, and lower network loss.


2014 ◽  
Vol 668-669 ◽  
pp. 749-752 ◽  
Author(s):  
Xiao Yi Zhou ◽  
Ling Yun Wang ◽  
Wen Yue Liang ◽  
Li Zhou

Distributed generation (DG) has an important influence on the voltage of active distribution networks. A unidirectional power distribution network will be transformed into a bidirectional, multiple power supply distribution network after DGs access to the distribution network and the direction of power flow is also changed. Considering the traditional forward and backward substitution algorithm can only deal with the equilibrium node and PQ nodes, so the other types of DGs should be transformed into PQ nodes, then its impact on active distribution network can be analyzed via the forward and backward substitution algorithm. In this paper, the characteristics of active distribution networks are analyzed firstly and a novel approach is proposed to convert PI nodes into PQ nodes. Finally, a novel forward and backward substitution algorithm is adopted to calculate the power flow of the active distribution network with DGs. Extensive validation of IEEE 18 and 33 nodes distribution system indicates that this method is feasible. Numerical results show that when DG is accessed to the appropriate location with proper capacity, it has a significant capability to support the voltages level of distribution system.


Author(s):  
Satya PRAKASH ◽  
Manoj HANS ◽  
Vikas THORAT

The power distribution network has grown complex and vulnerable as it increases its demand. The system's reliability has become a prominent factor for the end-users, although the continuity of supply in the distribution network still remains a challenge. In order to achieve the same distribution, automation came into the picture. The term “Distribution Automation” usually refers to an advanced switching system, which works as a subsystem of the existing network. The purpose of the subsystem is to offer real-time observation and control in distribution networks and electricity market operations. Consequently, the development of an autonomous system for isolating failures and restoring power for the distribution of LV (low voltage)/MV (medium voltage) can be an attractive solution for improving energy facilities' reliability. Advanced management techniques are devices and algorithms used to analyze, diagnose, and predict conditions in a distribution network, as well as to identify and take appropriate corrective actions to eliminate, mitigate, and prevent power outages and power quality problems. To demonstrate the model, we used a PIC16F877, CT microcontroller, and a power supply unit.


2012 ◽  
Vol 516-517 ◽  
pp. 1425-1428
Author(s):  
Li Ming Wei ◽  
Jun Lin

The introduction of distributed generation will bring new challenges to the theory of power electricity market. The problem of loss allocation is one of them. In the paper three contents are introduced. Firstly, a loss allocation method is proposed for power distribution network with distributed generation. Secondly, the changes of loss allocation which introduction of distributed generation before and after brings about are analyzed and compared and relevant conclusions are obtained. Lastly, a typical mini-grid with a distributed generation is simulated. Simulation results prove the correctness and feasibility of the method.


Sign in / Sign up

Export Citation Format

Share Document