Study of Improving Low Voltage Ride - Through Capability of Doubly - Fed Induction Generator by Using DVR

2014 ◽  
Vol 607 ◽  
pp. 531-535
Author(s):  
Chen Jian ◽  
Ren Yong Feng ◽  
Hu Hong Bin

with the increasing proportion of wind power in whole power system ,the influence between wind power system and grid become more and more seriously ,so it is great important to research how to keep the connection between the wind power system and grid when grid voltage drops .The paper presents a new method to realize the low voltage ride - through (LVRT) of DFIG by using dynamic voltage restorer (DVR). Once the grid voltage drops,DVR will be put into use and produce compensation voltage to keep the stator side voltage steady .And it also can stop operation after the fault resolution.The paper builds a simulation model of DFIG and gives simulation results on PSCAD/EMTDC platform .

2014 ◽  
Vol 1070-1072 ◽  
pp. 209-215
Author(s):  
Mei Zhang ◽  
Hai Qin Xue ◽  
Shui Liang Zhou

The exiting of wind turbines will cause the adverse effect on the power grid and its assembling unit in network voltage drops. So, direct-drive wind power generation system should meet the requirement of the certain ability of low voltage. This paper introduces the influence of wind power system with different structure by voltage drop as well as the disadvantage and advantage on LVRT. The relate regulations based on LVRT are analyzed. The existing LVRT technologies of direct-drive wind power systems are briefly presented. The characteristics of each scheme from the different LVRT technology are analyzed. Moreover, further study of LVRT for PMSG is pointed out.


Doubly Fed Induction Generator (DFIG) based wind Energy System are very sensitive to grid disturbance such as Symmetrical voltage sag. In this paper the authors propose a new method for application of Dynamic Voltage Restorer for enhancing the low voltage ride through capability of wind turbine driven Doubly Fed Induction Generator.


2014 ◽  
Vol 875-877 ◽  
pp. 1723-1728
Author(s):  
Xi Yun Yang ◽  
Li Xia Li ◽  
Ya Min Zhang ◽  
Jin Gao

The DC bus voltage is the main criteria to reflect whether the converter system is working properly or not, and the stability control of the DC bus voltage is the key to ensure that wind power generators not take off the grid when grid voltage drops. This paper had done research on a direct-drive wind power system and proposed a coordinated control method based on the grid voltage information feedforward with a crowbar circuit. The hardware was combined with the improved control strategy in this method. When the grid voltage drops, the extra energy of the DC bus can be unleashed by the crowbar circuit, at the same time, the output power of motor-side can be controlled according to the grid-side information, and the mechanical speed of motor-side can be suppressed by the pitch angle regulation when the output power reduces. Thus, the DC-bus voltage can be keep stability. Results based on Matlab/Simulink simulation shows that this method not only improves the stability and dynamic response performance of the DC bus voltage, but also effectively maintains the output power of generator and reduces the action time of crowbar circuit. The ability of the wind power system riding through the grid fault has been effectively improved.


Sign in / Sign up

Export Citation Format

Share Document