Use Differential Pulse Voltammetry for Determining the 2,6-Ditertbutyl-4-Methylphenol in Jet Fuels

2012 ◽  
Vol 455-456 ◽  
pp. 716-720 ◽  
Author(s):  
Yong Gang Shi ◽  
Bin Su ◽  
Hai Feng Gong ◽  
Yan Xue

A new method for determination of antioxidants in jet fuels, which is based on the differential pulse voltammetric characteristics of the antioxidant 2,6-ditertbutyl-4-methylphenol in the solution of saturated KOH anhydrous ethyl alcohols, is established. The experimental results have shown that there is a linear relationship between the content of 2,6-ditertbutyl-4-Methyl-phenol in the jet fuel and the differential pulse voltammetry response in the electrolytic solution. It has also been shown that the antioxidant contents can be reliably and simply determined with the help of the standard addition method. The largest relative error of the determination is 6.70 %, the biggest confidence for 5 samples is 1.95 mg/L (n=5, 95% confidence level).

2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
C. Montes ◽  
J. H. Vélez ◽  
G. Ramírez ◽  
M. Isaacs ◽  
R. Arce ◽  
...  

In the present work, known concentration of sulfite aqueous solutions in the presence and absence of gallic acid was measured to corroborate the validity of modified Monier-Williams method. Free and bound-sulfite was estimated by differential pulse voltammetry. To our surprise, the modified Monier-Williams method (also known as aspiration method) showed to be very inaccurate for free-sulfite, although suitable for bound-sulfite determination. The differential pulse approach, using the standard addition method and a correction coefficient, proved to be swift, cheap, and very precise and accurate.


1986 ◽  
Vol 51 (11) ◽  
pp. 2466-2472 ◽  
Author(s):  
Jiří Barek ◽  
Antonín Berka ◽  
Ludmila Dempírová ◽  
Jiří Zima

Conditions were found for the determination of 6-mercaptopurine (I) and 6-thioguanine (II) by TAST polarography, differential pulse polarography and fast-scan differential pulse voltammetry at a hanging mercury drop electrode. The detection limits were 10-6, 8 . 10-8, and 6 . 10-8 mol l-1, respectively. A further lowering of the detection limit to 2 . 10-8 mol l-1 was attained by preliminary accumulation of the determined substances at the surface of a hanging mercury drop.


1991 ◽  
Vol 56 (3) ◽  
pp. 595-601 ◽  
Author(s):  
Jiří Barek ◽  
Gulamustafa Malik ◽  
Jiří Zima

Optimum conditions were found for the determination of 4-nitrobiphenyl by fast scan differential pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 . 10-5 to 2 . 10-7 mol l-1. A further increase in sensitivity was attained by adsorptive accumulation of this substance on the surface of the working electrode, permitting determination in the concentration range (2 – 10) . 10-8 mol l-1 with one minute accumulation of the substance in unstirred solution or (2 – 10) . 10-9 mol l-1 with three-minute accumulation in stirred solution. Linear scan voltammetry can be used to determine 4-nitrobiphenyl in the concentration range (2 – 10) . 10-9 mol l-1 with five-minute accumulation in stirred solution, with the advantage of a smoother baseline and smaller interference from substances that yield only tensametric peaks.


2021 ◽  
Author(s):  
Yan Jin ◽  
Tong QI ◽  
Yuqing Ge ◽  
Jin Chen ◽  
Li juan Liang ◽  
...  

In this paper, ultrasensitive electrochemical determination of phosphate in water is achieved by hydrophilic TiO2 modified glassy carbon electrodes for the first time. Differential pulse voltammetry (DPV) method is proposed...


2017 ◽  
Vol 9 (37) ◽  
pp. 5449-5454 ◽  
Author(s):  
Min Wei ◽  
Shuo Feng

A signal-off aptasensor for OTA detection at an apt/cDNA/AuNPs/cPC/NH2–AuE electrode using methylene blue as an electrochemical probe.


2011 ◽  
Vol 76 (5) ◽  
pp. 383-397 ◽  
Author(s):  
Ferenc T. Pastor ◽  
Hana Dejmková ◽  
Jiří Zima ◽  
Jiří Barek

The possibility of determination of chloramphenicol by differential pulse voltammetry at four different carbon paste electrodes, in the full pH range (2–12) of Britton–Robinson (BR) buffer was investigated. Electrodes were prepared by mixing spectroscopic graphite powder or glassy carbon microbeads with mineral oil (Nujol) or tricresyl phosphate. Under optimal conditions (BR buffer pH 12, the electrode prepared from glassy carbon microbeads and tricresyl phosphate), linear calibration graph was obtained only in 10–5 M chloramphenicol concentration range. Determination of lower concentrations of chloramphenicol was complicated by irreproducible peak of oxygen from the carbon paste which overlapped with peak of chloramphenicol. Addition of sodium sulfite removed the oxygen peak without influence on the peak of chloramphenicol. Under optimal conditions (electrode paste made from glassy carbon microbeads, BR buffer pH 10 and 0.5 M sodium sulfite), straight calibration line was obtained in the 10–6 and 10–5 M chloramphenicol concentration range. Limit of determination was 5 × 10–7 mol/l.


Sign in / Sign up

Export Citation Format

Share Document