Simulation on Ground Temperature Change of GSHP System in Severe Cold Regions

2014 ◽  
Vol 945-949 ◽  
pp. 2820-2824 ◽  
Author(s):  
Li Bai ◽  
Peng Xuan Wang

For the case of ground-source heat pump in severe cold regions in winter, the heat transfer situation of the ground and ground heat exchanger was dynamically simulated according to the statistics of a project in Changchun to analysis the change of the ground heat, which provided references for the initial design and operation and management of the ground-coupled heat pump in severe cold regions.

2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2014 ◽  
Vol 529 ◽  
pp. 625-629
Author(s):  
Chao Yi Tan ◽  
Peng Fei Yang ◽  
Meng Meng Wang ◽  
Hai Hua Hu ◽  
Guo Qiang Zhang

In order to improve EER of the ground source heat pump system and reduce heat transfer area of the ground heat exchanger, the authors had developed a series connection ground source heat pump water chiller-heater unit, after theoretical analyses, proved that placing the water chilled in front of the hot water unit could acquire a higher EER comparing to the opposite. In the meantime, this unit had a higher EER than a common water chiller-heater unit or a water chiller-heater unit with condensing heat recovery device. In an air conditioning system of ground source heat pump, employing the above mentioned unit can also reduce heat transfer area of the ground heat exchanger. It suggested that series connection ground source heat pump water chiller-heater unit is a kind of technology with a great development potential.


2013 ◽  
Vol 700 ◽  
pp. 231-234
Author(s):  
Lian Yang ◽  
Yong Hong Huang ◽  
Liu Zhang

There are many ground source heat pumps in engineering construction application. However, Research on heat exchanger models of single-hole buried vertical ground source heat pump mostly focuses on single U-tube ground heat exchangers other than double U-tube ones in China currently. Compared with single U-tubes, double U-tubes have the heat transfer particularity of asymmetry. Therefore, the use of the traditional single tube models would have large error in the simulation of the actual double U-tube heat exchangers. This paper frames a three-dimensional heat transfer model for the vertical single-hole buried double u-tube heat exchanger in a ground source heat pump system. The model considers the performance of U-bube material and uses a dual coordinate system and makes the control elemental volumes superimposed.


2019 ◽  
Vol 11 (11) ◽  
pp. 363-378
Author(s):  
Arif Widiatmojo ◽  
Shrestha Gaurav ◽  
Takeshi Ishihara ◽  
Akira Tomigashi ◽  
Kasumi Yasukawa ◽  
...  

Proceedings ◽  
2020 ◽  
Vol 51 (1) ◽  
pp. 24
Author(s):  
Piotr Rynkowski

In this paper, experimental studies were performed for a solar ground source heat pump system (SGSHPS) with a vertical ground heat exchanger (VGHE). The experiment was operated during the summer in 2018. The heat from the solar collector was monitored by measuring the inlet and outlet temperatures and flow rate of the heat transfer fluids. An energy equilibrium balance carried out indicates heat extraction from the solar collector to the ground heat exchanger. It has been established that clear impact is achieved within a radius of 5 m. The average temperature of the actively regenerated borehole was higher than that of the undisturbed profile, which has a direct impact on the significant benefits of the coefficient of performance (COP) of the ground source heat pump system (GSHPS) and effectively helps soil regeneration. The average efficiency ratio of the heat transferred from solar radiation to soil in the SGSHPS was 42.3%.