outlet temperature
Recently Published Documents


TOTAL DOCUMENTS

935
(FIVE YEARS 324)

H-INDEX

24
(FIVE YEARS 5)

Author(s):  
Minhua Huang ◽  
Haiqiao Wang ◽  
Feng Tian ◽  
Junxin Huang ◽  
Shiqiang Chen ◽  
...  

This study proposes a downstream single-row air washer for air cooling. The theoretical energy and exergy balance models were established at different droplet diameters and verified by the experimental data. Based on the abovementioned theoretical relationship, the single performance indicator of heat exchange efficiency (HEE) and exergy efficiency was quantitatively analyzed; a comprehensive analysis method of two indicators was proposed, combining HEE and exergy efficiency, and a numerical simulation was carried out. Results show that the smaller the droplet diameter and the larger the water–air ratio, the lower the dry-bulb temperature of the outlet air and the higher the HEE and exergy flux destruction. When the droplet diameter is less than 440 μm, the droplet diameter does not affect exergy efficiency and dry-bulb temperature. When the droplet diameter is larger than 440 μm, the droplet diameter is positively correlated with the air outlet dry-bulb temperature and exergy efficiency; in contrast, the water–gas ratio is negatively correlated with the air outlet dry-bulb temperature. An engineering case reveals that when the air outlet temperature is less than 34°C, the critical water–gas ratio can be set as 2.6 (mass ratio). At this time, the HEE is more than 90%, the exergy efficiency is more than 60%, and the critical value of droplet diameter is 440 μm. The research results provide an essential theoretical basis for the optimization of engineering design calculation.


Water ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 127
Author(s):  
Gaoli Zhao ◽  
Pavel G. Talalay ◽  
Xiaopeng Fan ◽  
Nan Zhang ◽  
Yunchen Liu ◽  
...  

Hot-water drilling in ice with near-bottom circulation is more advantageous than traditional hot-water drilling with all-over borehole circulation in terms of power consumption and weight. However, the drilling performance of this type of drill has been poorly studied. Initial experiments showed that drilling with single-orifice nozzles did not proceed smoothly. To achieve the best drilling performance, nozzles with different orifice numbers and structures are evaluated in the present study. The testing results show that a single-orifice nozzle with a 3 mm nozzle diameter and a nine-jet nozzle with a forward angle of 35° had the highest rate of penetration (1.7–1.8 m h−1) with 5.6–6.0 kW heating power. However, the nozzles with backward holes ensured a smoother drilling process and a larger borehole, although the rate of penetration was approximately 13% slower. A comparison of the hollow and solid thermal tips showed that under the same experimental conditions, the hollow drill tip had a lower flow rate, higher outlet temperature, and higher rate of penetration. This study provides a prominent reference for drilling performance prediction and drilling technology development of hot-water drilling in ice with near-bottom circulation.


2022 ◽  
Vol 355 ◽  
pp. 02059
Author(s):  
Zhimo Li ◽  
Jiachun Li ◽  
Xiangli Dong ◽  
Bo Chen ◽  
Qing Li

Aiming at the current problems of coal-fired boilers and electromagnetic induction steam generators for environmental pollution and high energy consumption, this article combines air source heat pumps and electromagnetic induction heating technology, and at the same time carries out the structure of the condensate tank and electromagnetic induction steam generator. Redesign. Through trial production and experimentation of the prototype, the results show that compared with traditional coal-fired boilers and separate electromagnetic induction heating technology to generate steam, this device not only achieves energy saving and environmental protection, but also the stability of the steam outlet temperature and the amount of steam generated. Compared with the use of electromagnetic induction heating alone, it has increased by 20%. It can be seen that the use of air source heat pump’ electromagnetic induction heating technology to generate steam saves energy and increases the amount of steam generated.


Author(s):  
Mario Rüttgers ◽  
Moritz Waldmann ◽  
Wolfgang Schröder ◽  
Andreas Lintermann

AbstractMany simulation workflows require to prepare the data for the simulation manually. This is time consuming and leads to a massive bottleneck when a large number of numerical simulations is requested. This bottleneck can be overcome by an automated data processing pipeline. Such a novel pipeline is developed for a medical use case from rhinology, where computer tomography recordings are used as input and flow simulation data define the results. Convolutional neural networks are applied to segment the upper airways and to detect and prepare the in- and outflow regions for accurate boundary condition prescription in the simulation. The automated process is tested on three cases which have not been used to train the networks. The accuracy of the pipeline is evaluated by comparing the network-generated output surfaces to those obtained from a semi-automated procedure performed by a medical professional. Except for minor deviations at interfaces between ethmoidal sinuses, the network-generated surface is sufficiently accurate. To further analyze the accuracy of the automated pipeline, flow simulations are conducted with a thermal lattice-Boltzmann method for both cases on a high-performace computing system. The comparison of the results of the respiratory flow simulations yield averaged errors of less than 1% for the pressure loss between the in- and outlets, and for the outlet temperature. Thus, the pipeline is shown to work accurately and the geometrical deviations at the ethmoidal sinuses to be negligible.


2022 ◽  
Vol 960 (1) ◽  
pp. 012012
Author(s):  
Rm Popa ◽  
AT Borborean ◽  
V Stoica ◽  
I Ionel

Abstract In this scientific report the steps for achieving the energy balance on a test engine Daewoo 1.6 liter in 4 cylinders, with 4 valves per cylinder, its power being77 kW, are presented. The engine was connected to a hydraulic brake during the tests. The energy balance was established, based on measurements applied on the stand test, focusing to determine the lost heat and to conceive a Sankey diagram, accordingly. Two sets of measurements were performed and based on them the heat losses were determined and two Sankey diagrams were depicted. The lost heat through the cooling fluid is determined by measuring the cooling water flow rate and its inlet and outlet temperature. The lost heat through the exhaust gases is determined by the difference between the enthalpy of the exhaust gases and the enthalpy of fresh air. The lost heat due to incomplete chemical combustion is determined by analyzing the composition of the exhaust gases. The measurements are centralized on a graphic user interface, supported by a NI Compact RIO platform.


2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Rajkumar Malviya ◽  
Prashant V. Baredar ◽  
Anil Kumar

The present research intends to design an efficient receiver for solar thermal applications with a solar dish concentrator system. Thermal and dynamic analysis is carried out for different convolutions of a spiral coil, and experiments are performed for testing the modified absorber. Experimental results are validated for the spiral absorber with numerical results. Three receivers of different numbers of convolutions are analyzed, and simulation steps are performed for these receivers to make improvements in the system efficiency. Finally, 5 convolutions of a spiral coil tubular absorber are taken for the modified design of the system. Absorber position for every spiral convolution is kept at the focus of the concentrated solar dish collector to achieve maximum efficiency. Material used for the reflective surface is anodized aluminum and copper for the absorber. The diameter of the aperture for the parabolic dish collector is 1.4 m. The maximum absorber temperature for May month comes out to be 296°C, and the maximum working fluid outlet temperature is found to be 294.2°C which is near to simulating temperature of 289.59°C and 288.15°C, respectively. This innovative design of the absorber consists of a feature of a 5 mm extension to the spiral tube at the exit and entry; hence, the turbulence effect could be overcome. Experimental thermal efficiency was found the highest (i.e., η th max = 75.98 % ) for May. This work emphasizes on improving thermal performance by obtaining optimum absorber size using convolution strategy. Investigation of 5 convolutions of spiral coil tubular absorber with extended ends for obtaining optimum performance than existing work is the superiority of this work.


2021 ◽  
Vol 12 (3) ◽  
pp. 061-071
Author(s):  
Samer Yassin Alsadi ◽  
Tareq Foqha

Little works considered the optimization of working fluids in solar systems. Engineers, designers and scientists are interested with the optimization problems, furthermore it is very important specially, for solar systems to improve the energetic behavior and increase their efficiencies as a conversion system of solar irradiance to a useful thermal power. According to the available literature, the criteria of optimization mainly relates to energetic and economic analysis (one of them or both). The analysis was based upon the maximum useful energy obtained from solar collector. Accordingly, the optimum mass flow rate was found aspires to infinity. The second analysis is based upon minimum cost of the unit of useful energy [$/W]. The optimum mass flow rate of solar air-heating flat-plate collector for the considered domestic solar heating system has been found 29 kg/h per square meters of solar collectors. This paper deals with a third criteria that is, the amount of the additional energy required to achieve the required task from the solar system by means of auxiliary heating system. In where both the outlet temperature and mass flow rate play crucial role in the heat exchange between the fluid in the collector loop and the fluid in the load loop.


2021 ◽  
Vol 15 ◽  
pp. 254-259
Author(s):  
Enrique Torres Tamayo ◽  
José W. Morales ◽  
Mauro D. Albarracín ◽  
Héctor L. Laurencio ◽  
Israel P. Pachacama ◽  
...  

The parameters behavior that characterize the process was carried out through an experimental investigation to obtain the cooling temperature, heat transfer coefficients and the heat flow in mineral coolers. The values of water temperature, water flow and mineral temperature were recorded at the inlet and outlet of the cylindrical cooler. Experiments were carried out with five values of the mass flow, keeping the cylinder revolutions constant. The calculation procedure for the system was obtained, in the mineral coolers the heat transfer by conduction, convection and evaporation predominates as a function of the cooling zone. A reduction in temperature is shown with increasing length, the lowest temperature values were obtained for a mass flow of 8 kg/s. The mineral outlet temperature should not exceed 200 oC, therefore it is recommended to work with the mass flow less than 10 kg/s that guarantees the cooling process.


Author(s):  
Alexandr Zarvin ◽  
Alexandr Yaskin ◽  
Valeriy Kalyada ◽  
Kirill Dubrovin

Abstract Experimental results of observing ethanol micro-jets expiring into a highly rarefied medium (vacuum) through a nozzle are presented. The study of the process was carried out both at the horizontal and vertical liquid stream from the source compared to the direction of gravity The residual background gas pressure in the vacuum chamber was maintained at a level much lower than the saturated vapor pressure of the working fluid at a given outlet temperature. The possibility of modeling complex processes of micro-fluids expiring into a medium with a given rarefied atmosphere on a compact vacuum gas-dynamic stand is shown. It is established that the long-term flow from a thin capillary or a small-diameter hole into a vacuum or a highly rarefied gas medium differs significantly from the well-studied flow modes into a dense gas medium, as well as from the pulsed flow modes into a vacuum. The paper describes the main features of the flow and the conditions for the occurrence of instability. It is shown that the long-term flow of a liquid micro-jet in a vacuum has a high degree of surface instability, with a large number of sudden changes in the direction, structure, and observed density. An explanation of the reasons for the destruction of the micro-jet is proposed. The formation of surface gas caverns causing explosive destruction of the micro-jet with the release of vapor-liquid droplets is established.


2021 ◽  
Vol 12 (1) ◽  
pp. 17
Author(s):  
Muhammad Hasnain Tariq ◽  
Farooq Khan ◽  
Taqi Ahmad Cheema

Utilization of solar energy is increasing in different states of the world, and the sun is regarded as the largest source of continuous and coherent energy. In the present study, a novel configuration of a v-corrugated solar collector with triangular channels for domestic water heating has been analytically investigated. A mathematical model based on effectiveness-NTU method is established to thermally examine the collector. Additionally, the heat losses from the body of the collector, useful energy from the collector and solar efficiency have been calculated analytically over different operating parameters. The effects of mass flow rate and solar heat flux on water outlet temperature are evaluated analytically and compared with the experimental results. Moreover, the study includes the experimental and theoretical investigation of the heat exchange effectiveness and thermal efficiency of the proposed absorber. The study shows that high temperature and high performance can be obtained from this collector as more heat energy can be collected by using triangular channels because all the three sides of these channels are exposed to solar radiations at the same time. Therefore, these channels will enhance the collector exposed surface area and thereby increase the solar efficiency and overall performance of the system.


Sign in / Sign up

Export Citation Format

Share Document