Retrieval Study of Total Hip Arthroplasty with Use of a Cemented Polyethylene Cup and a Non-cemented Polyethylene Liner in Combination with Zirconia Ceramic Femoral Head: Report of 2 Cases

2003 ◽  
Vol 38 (6) ◽  
pp. 573
Author(s):  
Young Yong Kim ◽  
Yerl Bo Sung ◽  
Kang Jin Kwon ◽  
Yong San Yoon ◽  
Hae Soo Park
2012 ◽  
Vol 529-530 ◽  
pp. 279-284 ◽  
Author(s):  
Taishi Sato ◽  
Yasuharu Nakashima ◽  
Mio Akiyama ◽  
Takuaki Yamamoto ◽  
Taro Mawatari ◽  
...  

The purpose of this study was to examine the effects of ceramic femoral head material on the wear of annealed, crosslinked ultra-high molecular weight polyethylene (UHMWPE) (XLPE) in total hip arthroplasty compared to non-crosslinked conventional UHMWPE (CPE). XLPE was fabricated by crosslinking with 60 kGy irradiation and annealing. Femoral heads made from zirconia and alumina ceramics, and cobalt-chrome (CoCr) of 22 mm or 26 mm diameter were used. In this study, the femoral head penetration into the cup was measured digitally on radiographs of 70 hips with XLPE and 50 hips with CPE. The average follow-up periods were 6.1 and 12.7 years, respectively. The steady wear rate of XLPE was significantly lower than those of CPE (0.002 versus 0.08 mm/year, respectively). Zirconia displayed increased wear rates compared to alumina in CPE; however, there was no difference among head materials in XLPE (0.0028, 0.011 and 0.009 mm/year for zirconia, alumina and CoCr, respectively). Neither head size or implantation period impacted XLPE wear. In contrast to CPE, XLPE displayed low wear rates surpassing the effects of varying femoral head material, size, implantation period and patient demographics.


1999 ◽  
Vol 81 (10) ◽  
pp. 1446-9 ◽  
Author(s):  
BRADLEY K. VAUGHN ◽  
THOMAS B. DAMERON ◽  
THOMAS W. BAUER ◽  
YUICHI MOCHIDA ◽  
TOSHIHIRO AKISUE ◽  
...  

2019 ◽  
Vol 101 (5) ◽  
pp. 421-428 ◽  
Author(s):  
Stephen M. Petis ◽  
Bernd Kubista ◽  
Robert U. Hartzler ◽  
Matthew P. Abdel ◽  
Daniel J. Berry

2016 ◽  
Vol 2016 ◽  
pp. 1-5
Author(s):  
Tomoya Takasago ◽  
Tomohiro Goto ◽  
Keizo Wada ◽  
Daisuke Hamada ◽  
Toshiyuki Iwame ◽  
...  

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a metal femoral head provides satisfactory results. We report an unusual case of progressive osteolysis due to metallosis that developed after revision THA for ceramic liner dissociation without a liner fracture performed using a metal femoral head and polyethylene liner. The residual metal debris and abnormal pumping motion of the polyethylene liner due to the breakage of the locking system or the aspherical metal shell being abraded by the ceramic head seemed to be the cause of the progressive osteolysis.


2003 ◽  
Vol 85 (5) ◽  
pp. 825-830 ◽  
Author(s):  
JÉRÔME ALLAIN ◽  
FRANÇOISE ROUDOT-THORAVAL ◽  
JOEL DELECRIN ◽  
PHILIPPE ANRACT ◽  
HENRI MIGAUD ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document