metal debris
Recently Published Documents


TOTAL DOCUMENTS

178
(FIVE YEARS 59)

H-INDEX

22
(FIVE YEARS 2)

Micromachines ◽  
2021 ◽  
Vol 12 (11) ◽  
pp. 1407
Author(s):  
Haotian Shi ◽  
Dian Huo ◽  
Hongpeng Zhang ◽  
Wei Li ◽  
Yuqing Sun ◽  
...  

The cleanliness of hydraulic oil can reflect the service life of the oil and the wear state of hydraulic machinery. An impedance sensor is proposed to distinguish multi-contaminants in hydraulic oil. The impedance sensor has two detection modes: the inductance-resistance mode is used to detect metal debris, and the capacitance mode is used to distinguish water droplets and air bubbles. By adding a built-in silicon steel strip and an external silicon steel strip with high magnetic permeability, the distribution area, strength, and uniformity of the magnetic field are enhanced to improve the detection sensitivity under inductance and resistance parameters. In addition, the silicon steel strips are used as electrode plates to introduce capacitance parameter detection. The experimental results show that the resistance detection method based on coil successfully improves the detection ability for non-ferromagnetic metal debris. The impedance sensor for distinguishing multi-contaminants in hydraulic oil can provide technical support for fault diagnosis of offshore hydraulic machinery.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7556
Author(s):  
Xianwei Wu ◽  
Yinghong Zhang ◽  
Nian Li ◽  
Zhenghua Qian ◽  
Dianzi Liu ◽  
...  

Lubricants are of key importance for mechanical processing, and exist in nearly every mechanical system. When the equipment is in operation, debris particles will be generated in mechanical lubricants. The detection of debris particles can indicate the wear degree of machinery components, and provide prognosis warning for the system before the fault occurs. In this work, a novel type of inductive debris sensor consisting of two excitation coils and two sensing coils is proposed for online debris monitoring. The developed sensor was proven to be of high sensitivity through experimental verification. The testing results show that, using the designed sensor, ferrous metal debris with a size of 115 μm and nonferrous metal debris with a size of 313 μm in a pipe with an inner diameter of 12.7 mm can be effectively detected. Moreover, the proposed inductive debris sensor structure has better sensitivity at higher throughput and its design provides a useful insight into the development of high-quality sensors with superior performances.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Nurlatifah ◽  
Haruhiko Nakata

AbstractPlastic debris has gained attention as anthropogenic waste in the environment, but less concerned given to metal waste despite its high abundance in aquatic environment. Metal packaging, such as can, utilizes polymeric coating films as barrier between metals and products which leads to be potential source of microplastic pollution. In this study, 27 beer cans from 16 countries for both body and lid parts as well as inside and outside layers were investigated. Despite the country’s origin, epoxy resin was the major polymeric coating used in all beer cans for lid (inside and outside) and body (inside). Whereas poly(1,2-butanediol isophthalate) was frequently used for outside layer of can body. DEHP and BHT were detected in almost all samples with the highest concentration of 5300 ng/g and 520 ng/g. Despite its lower detection frequency, DOA was detected as high as 9600 ng/g in Belgian beer can. There was no apparent relationship present between the home countries of beer cans and amount of additives used. Despite of being broken down, additives concentration in one environmental sample was found to be one to two orders of magnitude higher compared to the new can. This result proved that adsorption of chemical additives took place in the environment and degraded metal debris may become source of microplastic with higher risk of additives pollution in the environment.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Peter Caspar Bünemann ◽  
Stefan Luck ◽  
Malte Ohlmeier ◽  
Thorsten Gehrke ◽  
Tobias Malte Ballhause

Osteoarthritis of the hip joint (coxarthrosis) is the most common hip disease in adults. Since the 1960s, total hip arthroplasty (THA) has made great progress and is nowadays one of the most frequently used procedures in orthopedic surgery. Different bearing concepts exist in various implant designs. A metal-on-metal bearing can create metal debris and lead to metallosis. We present a unique case of a 78-year old woman, who received hip resurfacing with a McMinn-like prosthesis 15 years ago. Over the cause of time, metallosis developed and created a bone cyst in the Os ilium, and osteolysis led to a dislocation of the femoral implant. A minor stumble fall led to a fracture of the Os ilium. We present our treatment method with implantation of a cemented THA and refill of the bone cyst with bone from allogene femoral heads. The surgery led to a reconstruction of the physiological center of rotation in the hip. Consequently, to the inpatient stay, the patient took part in a follow-up treatment with intensive physiotherapy. Taken together, the results after total hip arthroplasty are more superior to other hip surface replacements in terms of longevity and patient satisfaction. Especially, metal-on-metal bearing couples carry a great risk of metallosis, which goes a long with pseudotumors, osteolysis, and the elevated metal ions in the blood. Since this case is unique in the literature, no guidelines are noted for surgical treatment. In our opinion, a periprosthetic fracture of this type should be performed in a hospital using extensive endoprosthetic expertise.


2021 ◽  
Vol 17 (3) ◽  
pp. 187-192
Author(s):  
Se Won Oh ◽  
Seung Yun Jee ◽  
Seong Oh Park

A pseudotumor is a benign granulomatous or cystic lesion associated with the deposition of metal debris in joint arthroplasties. To the best of our knowledge, this is the first report on a pseudotumor caused by the breakage of the Dall-Miles cable grip system, a multifilament cable used to fix the trochanteric osteotomy in revision total hip arthroplasty. This rare case demonstrates that pseudotumor formation can be caused by various types of orthopedic materials and implant components. When encountering a palpable mass around an orthopedic implant, a pseudotumor should be considered along other differential diagnoses. To treat pseudotumors and also prevent recurrence, its complete resection and sufficient removal of orthopedic materials are necessary.


Materials ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 6507
Author(s):  
Jorge Toledano-Serrabona ◽  
Francisco Javier Gil ◽  
Octavi Camps-Font ◽  
Eduard Valmaseda-Castellón ◽  
Cosme Gay-Escoda ◽  
...  

Implantoplasty is a mechanical decontamination technique that consists of polishing the supra-osseous component of the dental implant with peri-implantitis. This technique releases metal particles in the form of metal swarf and dust into the peri-implant environment. In the present in vitro study, the following physicochemical characterization tests were carried out: specific surface area, granulometry, contact angle, crystalline structure, morphology, and ion release. Besides, cytotoxicity was in turn evaluated by determining the fibroblastic and osteoblastic cell viability. As a result, the metal debris obtained by implantoplasty presented an equivalent diameter value of 159 µm (range 6–1850 µm) and a specific surface area of 0.3 m2/g on average. The particle had a plate-like shape of different sizes. The release of vanadium ions in Hank’s solution at 37 °C showed no signs of stabilization and was greater than that of titanium and aluminum ions, which means that the alloy suffers from a degradation. The particles exhibited cytotoxic effects upon human osteoblastic and fibroblastic cells in the whole extract. In conclusion, metal debris released by implantoplasty showed different sizes, surface structures and shapes. Vanadium ion levels were higher than that those of the other metal ions, and cell viability assays showed that these particles produce a significant loss of cytocompatibility on osteoblasts and fibroblasts, which means that the main cells of the peri-implant tissues might be injured.


2021 ◽  
Vol 11 ◽  
Author(s):  
Jonathan Liu ◽  
Alister Hart ◽  
Brendan Holderread ◽  
Terry Clyburn

Metal-on-metal (MoM) hip arthroplasty was re-popularized in the 1990s to resolve osteolysis and wear associated with metal-on-polyethylene products. Despite early success, registries began reporting high failure rates due to adverse reactions to metal debris (ARMD), manifesting as pseudotumors, hip effusions and osteolysis. Evaluation includes clinical exam, advanced imaging, and blood metal ions and infectious markers. This review provides physicians with an evidence-based update on the 1) clinical workup and management of patients with existing MoM implants, 2) risk and prognostic factors associated with suboptimal results and 3) the precipitating events and lessons learned applicable to future orthopedic prosthesis.


2021 ◽  
Vol 2 (9) ◽  
pp. 728-736
Author(s):  
Patrick Y. K. Chin ◽  
William D. Regan ◽  
Derek Plausinis ◽  
Zane D. Zarzour ◽  
Fay Leung ◽  
...  

Aims To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. Methods Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed. Results A total of 93 patients were randomized (46 TM; 47 POLY). No significant or clinically important differences were found with patient-reported outcomes at 24-month follow-up. Regarding the glenoid components, there were no complications or revision surgeries in either group. Grade 1 metal debris was observed in three (6.5%) patients with TM glenoids at 24 months but outcomes were not negatively impacted. Conclusion Early results from this RCT showed no differences in disease-specific QOL, radiographs, complication rates, or shoulder function between uncemented second-generation TM and cemented POLY glenoids at 24 months postoperatively. Revision surgeries and reoperations were reported in both groups, but none attributed to glenoid implant failure. At 24 months postoperatively, Grade 1 metal debris was found in 6.5% of patients with a TM glenoid but did not negatively influence patient-reported outcomes. Longer-term follow-up is needed and is underway. Cite this article: Bone Jt Open 2021;2(9):728–736.


2021 ◽  
Vol 171 ◽  
pp. 107074 ◽  
Author(s):  
Richmond K. Asamoah ◽  
Emmanuel Baawuah ◽  
Christopher Greet ◽  
William Skinner
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document