scholarly journals Test–retest reliability and correlates of 6-minute walk test in patients with primary osteoarthritis of knees

2016 ◽  
Vol 11 (4) ◽  
pp. 192 ◽  
Author(s):  
Sivachidambaram Kulandaivelan ◽  
Mahamed Ateef ◽  
Shaziya Tahseen
2011 ◽  
Vol 20 (4) ◽  
pp. 434-440 ◽  
Author(s):  
Mikael Andersson ◽  
Linda Moberg ◽  
Ulla Svantesson ◽  
Ann Sundbom ◽  
Henrik Johansson ◽  
...  

2000 ◽  
Vol 80 (1) ◽  
pp. 8-16 ◽  
Author(s):  
Mary B King ◽  
James O Judge ◽  
Robert Whipple ◽  
Leslie Wolfson

Abstract Background and Purpose. The reliability and responsiveness of 2 physical performance measures were assessed in this nonrandomized, controlled pilot exercise intervention. Subjects. Forty-five older individuals with mobility impairment (mean age=77.9 years, SD=5.9, range=70–92) were sequentially assigned to participate in an exercise program (intervention group) or to a control group. Methods. The intervention group performed exercise 3 times a week for 12 weeks that targeted muscle force, endurance, balance, and flexibility. Outcome measures were the 8-item Physical Performance Test (PPT-8) and the 6-minute walk test. Test-retest reliability and responsiveness indexes were determined for both tests; interrater reliability was measured for the PPT-8. Results. The intraclass correlation coefficient for interrater reliability for the PPT-8 was .96. Intraclass correlation coefficients for test-retest reliability were .88 for the PPT-8 and .93 for the 6-minute walk test. The intervention group improved 2.4 points and the control group improved 0.7 point on the PPT-8, as compared with baseline measurements. There was no change in 6-minute walk test distance in the intervention group when compared with the control group. The responsiveness index was .8 for the PPT-8 and .6 for the 6-minute walk test. Conclusion and Discussion. Measurements for both the PPT-8 and the 6-minute walk test appeared to be highly reliable. The PPT-8 was more responsive than the 6-minute walk test to change in performance expected with this functional training intervention.


2020 ◽  
pp. 112070001988861
Author(s):  
Ertugrul Yuksel ◽  
Bayram Unver ◽  
Serpil Kalkan ◽  
Vasfi Karatosun

Purpose: Performance-based outcome measures are becoming increasingly important in health care. The 2-minute walk test (2MWT) and the Timed Up and Go test (TUG) are frequently used in clinical trials as performance-based tests in many diseases including osteoarthritis. The purposes of this study were: (1) to determine test-retest reliability of data for the 2MWT and the TUG; (2) to determine minimal detectable change (MDC) scores for the TUG and 2MWT in patients with total hip arthroplasty (THA). Methods: 37 patients, who had undergone primary THA, were included. Patients twice performed trials for the 2MWT and TUG on the same day. In addition to demographic data of patients, the Harris Hip Score, 2MWT and TUG scores were recorded. Results: The TUG and 2MWT showed excellent test-retest reliability. The Intraclass correlation coefficient ICC (2,1), Standard error of measurement (SEM) and minimal detectable chance at the 95% CI (MDC95) for TUG were 0.96, 0.59 seconds and 1.62 seconds respectively. The ICC (2,1), SEM and MDC95 for 2MWT were 0.96, 6.37 m and 17.56 m respectively. Conclusion: Clinicians and researchers can be confident that greater changes than 1.62 seconds for TUG and 17.56 m for the 2MWT over time represent a real clinical change in rehabilitation process in patients with THA. Both the 2MWT and TUG may assist in early identification of patients who may need additional rehabilitation to reduce the potential for poor outcomes after THA. Therefore, both of these tests can be used in a clinical setting with a small measurement error.


Sign in / Sign up

Export Citation Format