scholarly journals Addition of magnetic resonance imaging to computed tomography-based three-dimensional conformal radiotherapy planning for postoperative treatment of astrocytomas: Changes in tumor volume and isocenter shift

2015 ◽  
Vol 04 (01) ◽  
pp. 018-020 ◽  
Author(s):  
Puneet Kumar Bagri ◽  
Akhil Kapoor ◽  
Daleep Singh ◽  
Mukesh Kumar Singhal ◽  
Satya Narayan ◽  
...  

Abstract Introduction: Postoperative radiotherapy is the current gold standard treatment in astrocytomas. Computed tomography (CT)-based radiotherapy planning leads to either missing of the tumor volume or underdosing. The aim of this prospective study was to study the changes in tumor volume on addition of magnetic resonance imaging (MRI) to CT-based three-dimensional radiotherapy treatment planning of astrocytomas. Materials and Methods: Twenty-five consecutive patients of astrocytoma (WHO grades I-IV) for postoperative three-dimensional conformal radiotherapy were included in this prospective study. Postoperative tumor volumes were contoured on CT-based images and recontoured on CT-MRI images after automated MRI co-registration on treatment planning system Eclipse 8.9.15 as per ICRU-50 report. Tumor volumes were compared with each other. Result: The MRI-based mean and median tumor volume was 24.24 cc ± 13.489 and 18.72 cc (range 5.6-46.48 cc), respectively, while for CT it was 19.4 cc ± 11.218 and 16.24 cc (range: 5.1-38.72 cc), respectively. The mean and median isocenter shift between CT and MRI was 4.05 mm and 4.39 mm (range 0.92-6.32 mm), respectively. There is a linear relationship between MRI and CT volume with a good correlation coefficient of R 2 = 0.989, and MRI-based tumor volume was 1.208 times as compared to CT volume. Statistical analysis using paired sample t-test for the difference in CT and MRI tumor volume was highly significant (P < 0.001). Conclusion: Addition of MRI to the CT-based three-dimensional radiation treatment planning reduces the chances of geographical miss or tumor under dosing. Thus, MRI should be an integral part of three-dimensional planning of astrocytomas.

Author(s):  
Yousif A. M. Yousif ◽  
Ali Judge ◽  
Jackson Zifodya

Abstract Aim: The aim of this study was to evaluate the use of Eclipse’s beam angle optimiser (BAO) for three-dimensional conformal radiotherapy planning. Materials and methods: Eleven 3D conformal lung plans, with varied tumour volumes, were retrospectively studied. For each clinical plan, a BAO plan was produced and then optimised by an experienced planner. Plan quality was assessed using International Commission on Radiation Units and Measurements (ICRU)-83 and  Radiation Therapy Oncology Group (RTOG) recommended dose reporting metrics for dose volume prescribing and reporting. Results: Differences in dose volume histograms for both methods showed no clinical significance. Planning target volume Dmax for both plans was comparable and within ICRU guidelines. Reported spinal cord Dmax and the doses to 33% and 67% volume of the heart were within the RTOG recommended limits. Mean lung V20 values for BAO and non-BAO plans were 20 and 16%, respectively. The average monitor units for the BAO plans were about 11% lower. The conformity and homogeneity indices were within the acceptable range for both cases. On average, it took 23 minutes to plan using the BAO compared to 68 minutes for the non-BAO plans. Conclusion: Eclipse BAO shows the potential to produce good quality conformal plans and reduce planning time. This process could be further refined with multi-leaf collimator and optimal collimator angle options.


Sign in / Sign up

Export Citation Format

Share Document