beam angle
Recently Published Documents


TOTAL DOCUMENTS

354
(FIVE YEARS 66)

H-INDEX

24
(FIVE YEARS 2)

Author(s):  
Bastiaan Wilhelmus Klaas Schipaanboord ◽  
Ben J M Heijmen ◽  
Sebastiaan Breedveld

Abstract Properly selected beam angles contribute to the quality of radiotherapy treatment plans. However, the Beam Angle Optimization (BAO) problem is difficult to solve to optimality due to its non-convex discrete nature with many local minima. In this study, we propose TBS-BAO, a novel approach for solving the BAO problem, and test it for non-coplanar robotic CyberKnife radiotherapy for prostate cancer. First, an ideal Pareto-optimal reference dose distribution is automatically generated using a priori multi-criterial fluence map optimization (FMO) to generate a plan that includes all candidate beams (total-beam-space, TBS). Then, this ideal dose distribution is reproduced as closely as possible in a subsequent segmentation/beam angle optimization step (SEG/BAO), while limiting the number of allowed beams to a user-selectable preset value. SEG/BAO aims at a close reproduction of the ideal dose distribution. For each of 33 prostate SBRT patients, 18 treatment plans with different pre-set numbers of allowed beams were automatically generated with the proposed TBS-BAO. For each patient, the TBS-BAO plans were then compared to a plan that was automatically generated with an alternative BAO method (Erasmus-iCycle) and to a high-quality manually generated plan. TBS-BAO was able to automatically generate plans with clinically feasible numbers of beams (∽25), with a quality highly similar to corresponding 91-beam ideal reference plans. Compared to the alternative Erasmus-iCycle BAO approach, similar plan quality was obtained for 25-beam segmented plans, while computation times were reduced from 10.7 hours to 4.8/1.5 hours, depending on the applied pencil-beam resolution in TBS-BAO. 25-beam TBS-BAO plans had similar quality as manually generated plans with on average 48 beams, while delivery times reduced from 22.3 to 18.4/18.1 min. TBS reference plans could effectively steer the discrete non-convex BAO.


Mathematics ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 159
Author(s):  
Guillermo Cabrera-Guerrero ◽  
Carolina Lagos

In intensity-modulated radiation therapy, treatment planners aim to irradiate the tumour according to a medical prescription while sparing surrounding organs at risk as much as possible. Although this problem is inherently a multi-objective optimisation (MO) problem, most of the models in the literature are single-objective ones. For this reason, a large number of single-objective algorithms have been proposed in the literature to solve such single-objective models rather than multi-objective ones. Further, a difficulty that one has to face when solving the MO version of the problem is that the algorithms take too long before converging to a set of (approximately) non-dominated points. In this paper, we propose and compare three different strategies, namely random PLS (rPLS), judgement-function-guided PLS (jPLS) and neighbour-first PLS (nPLS), to accelerate a previously proposed Pareto local search (PLS) algorithm to solve the beam angle selection problem in IMRT. A distinctive feature of these strategies when compared to the PLS algorithms in the literature is that they do not evaluate their entire neighbourhood before performing the dominance analysis. The rPLS algorithm randomly chooses the next non-dominated solution in the archive and it is used as a baseline for the other implemented algorithms. The jPLS algorithm first chooses the non-dominated solution in the archive that has the best objective function value. Finally, the nPLS algorithm first chooses the solutions that are within the neighbourhood of the current solution. All these strategies prevent us from evaluating a large set of BACs, without any major impairment in the obtained solutions’ quality. We apply our algorithms to a prostate case and compare the obtained results to those obtained by the PLS from the literature. The results show that algorithms proposed in this paper reach a similar performance than PLS and require fewer function evaluations.


Nanomaterials ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 72
Author(s):  
Stefano Bellucci ◽  
Volodymyr Fitio ◽  
Iryna Yaremchuk ◽  
Oleksandr Vernyhor ◽  
Yaroslav Bobitski

In this work the features of the resonance in a rectangular dielectric surface-relief gratings, illuminated with a limited cross-section Gaussian beam, have been studied. The rigorous coupled wave method and beam decomposition into the plane waves by the Fourier transform have been used. It is shown that there is a resonant wavelength for each thickness of the dielectric grating. The value of resonant wavelength depends on the beam angle of incidence on the gratings. Moreover, the two types of resonances can occur in the grating at certain grating parameters. The power reflection coefficient is practically equal to unity for the first type of resonance and is much smaller than unity, for the second one. The obtained results extend the knowledge regarding the nature of the waveguide resonance in the dielectric grating, considering the limited cross section beam, and they can increase its use in many applications.


2021 ◽  
Author(s):  
Kai Feng ◽  
Luoxi Hao ◽  
Shujian Dai

LED wide beam angle lamps have been widely used but might leading to glare or light pollution easily than traditional floodlighting lamps. Standards for wide beam angle products is not enough and a laboratory experiment was carried out in which visual and emotional comfort was used as evaluation items. 3 linear lamps (3000K/4000K/5000K) were used to evaluate emotional and visual comfort changes by performing different brightness or dynamic speed. Results showed that both brightness and dynamic speed could lead to negative feelings while emotional discomfort always occurs behind the eye’s discomfort. A higher brightness could leading to more negative evaluations, while some people think that medium brightness gives a more comfort feeling. A faster speed leads to more negative evaluation while some subjects prefer a medium speed (both in shading and erasure situations); In different lighting scenes, the significance of different indicators is different.


2021 ◽  
Author(s):  
Bionda Rozin ◽  
Daniel Carlos Guimarães Pedronette

Séries temporais possuem grande aplicabilidade nos mais diversos cenários, incluindo os domínios científicos, agrícola, econômico, entre outros. Portanto, criar representações efetivas de uma série temporal é uma tarefa desafiadora, pois possibilita análises mais precisas e, consequentemente, obtenção de resultados e conclusões mais assertivas em diversas tarefas de aprendizado de máquina. Uma das principais tarefas associadas é a classificação, que pode ser realizada a partir de diferentes representações computacionais das séries temporais. Este trabalho tem como principal objetivo melhorar a eficácia de tarefas de classificação, utilizando uma representação das séries temporais obtida pelo algoritmo Beam Angle Statistics, um extrator de características de contorno baseado em estatísticas angulares.


Cancers ◽  
2021 ◽  
Vol 13 (22) ◽  
pp. 5683
Author(s):  
Kristine Fjellanger ◽  
Liv Bolstad Hysing ◽  
Ben J. M. Heijmen ◽  
Helge Egil Seime Pettersen ◽  
Inger Marie Sandvik ◽  
...  

In this study, the novel iCE radiotherapy treatment planning system (TPS) for automated multi-criterial planning with integrated beam angle optimization (BAO) was developed, and applied to optimize organ at risk (OAR) sparing and systematically investigate the impact of beam angles on radiotherapy dose in locally advanced non-small cell lung cancer (LA-NSCLC). iCE consists of an in-house, sophisticated multi-criterial optimizer with integrated BAO, coupled to a broadly used commercial TPS. The in-house optimizer performs fluence map optimization to automatically generate an intensity-modulated radiotherapy (IMRT) plan with optimal beam angles for each patient. The obtained angles and dose-volume histograms are then used to automatically generate the final deliverable plan with the commercial TPS. For the majority of 26 LA-NSCLC patients, iCE achieved improved heart and esophagus sparing compared to the manually created clinical plans, with significant reductions in the median heart Dmean (8.1 vs. 9.0 Gy, p = 0.02) and esophagus Dmean (18.5 vs. 20.3 Gy, p = 0.02), and reductions of up to 6.7 Gy and 5.8 Gy for individual patients. iCE was superior to automated planning using manually selected beam angles. Differences in the OAR doses of iCE plans with 6 beams compared to 4 and 8 beams were statistically significant overall, but highly patient-specific. In conclusion, automated planning with integrated BAO can further enhance and individualize radiotherapy for LA-NSCLC.


Author(s):  
Tiago Ventura ◽  
Humberto Rocha ◽  
Brigida da Costa Ferreira ◽  
Joana Dias ◽  
Maria do Carmo Lopes

AbstractTwo methods for non-coplanar beam direction optimization, one for static beams and another for arc trajectories, were proposed for intracranial tumours. The results of the beam angle optimizations were compared with the beam directions used in the clinical plans. Ten meningioma cases already treated were selected for this retrospective planning study. Algorithms for non-coplanar beam angle optimization (BAO) and arc trajectory optimization (ATO) were used to generate the corresponding plans. A plan quality score, calculated by a graphical method for plan assessment and comparison, was used to guide the beam angle optimization process. For each patient, the clinical plans (CLIN), created with the static beam orientations used for treatment, and coplanar VMAT approximated plans (VMAT) were also generated. To make fair plan comparisons, all plan optimizations were performed in an automated multicriteria calculation engine and the dosimetric plan quality was assessed. BAO and ATO plans presented, on average, moderate global plan score improvements over VMAT and CLIN plans. Nevertheless, while BAO and CLIN plans assured a more efficient OARs sparing, the ATO and VMAT plans presented a higher coverage and conformity of the PTV. Globally, all plans presented high-quality dose distributions. No statistically significant quality differences were found, on average, between BAO, ATO and CLIN plans. However, automated plan solution optimizations (BAO or ATO) may improve plan generation efficiency and standardization. In some individual patients, plan quality improvements were achieved with ATO plans, demonstrating the possible benefits of this automated optimized delivery technique.


2021 ◽  
pp. 028418512110438
Author(s):  
Xiaoli Zheng ◽  
Jingying Hu ◽  
Jian Xu ◽  
Zhen Wang ◽  
Zhenyu Shu ◽  
...  

Background Rapid and accurate quantification of the supraspinatus outlet view (SOV) is a clinical challenge. Purpose To quantify the X-ray beam angle of the SOV using the horizontal angle of the subscapular spine line (SSSL) and to further verify the feasibility of this method. Material and Methods A total of 119 patients who underwent shoulder computed tomography (CT) examination were enrolled in the retrospective study. Three-dimensional (3D) CT reconstruction was performed and manually adjusted to provide the position similar to SOV. The rotation angle of the 3D image along the long axis of the human body (marked as β) was obtained. The horizontal angle of SSSL (marked as α) was measured on the anteroposterior localizer image of shoulder CT. Pearson correlation and linear regression correlation analysis were performed. In addition, the first-time success rate between the experience-based group and the measurement-based group were compared to verify the novel method. Results We found a linear correlation between α and β (r = 0.962; P = 0.000). There was no significant correlation between the experience-based group and the measurement-based group in terms of age ( P = 0.500), sex ( P = 0.397), and side ( P = 0.710), but there was a significant statistical difference in the first success rate between the two validation groups (χ2 = 5.808a, P = 0.016). Conclusion This novel quantitative measurement method for determining the X-ray beam angle of SOV using the horizontal angle of SSSL is feasible.


2021 ◽  
Vol 11 ◽  
Author(s):  
Rik Bijman ◽  
Linda Rossi ◽  
Tomas Janssen ◽  
Peter de Ruiter ◽  
Baukelien van Triest ◽  
...  

BackgroundWith the large-scale introduction of volumetric modulated arc therapy (VMAT), selection of optimal beam angles for coplanar static-beam IMRT has increasingly become obsolete. Due to unavailability of VMAT in current MR-linacs, the problem has re-gained importance. An application for automated IMRT treatment planning with integrated, patient-specific computer-optimization of beam angles (BAO) was used to systematically investigate computer-aided generation of beam angle class solutions (CS) for replacement of computationally expensive patient-specific BAO. Rectal cancer was used as a model case.Materials and Methods23 patients treated at a Unity MR-linac were included. BAOx plans (x=7-12 beams) were generated for all patients. Analyses of BAO12 plans resulted in CSx class solutions. BAOx plans, CSx plans, and plans with equi-angular setups (EQUIx, x=9-56) were mutually compared.ResultsFor x>7, plan quality for CSx and BAOx was highly similar, while both were superior to EQUIx. E.g. with CS9, bowel/bladder Dmean reduced by 22% [11%, 38%] compared to EQUI9 (p<0.001). For equal plan quality, the number of EQUI beams had to be doubled compared to BAO and CS.ConclusionsComputer-generated beam angle CS could replace individualized BAO without loss in plan quality, while reducing planning complexity and calculation times, and resulting in a simpler clinical workflow. CS and BAO largely outperformed equi-angular treatment. With the developed CS, time consuming beam angle re-optimization in daily adaptive MR-linac treatment could be avoided. Further systematic research on computerized development of beam angle class solutions for MR-linac treatment planning is warranted.