Dual mobility total hip arthroplasty in patients at risk for dislocation

2020 ◽  
Vol 18 (3) ◽  
pp. 247
Author(s):  
MohamedM.M Mahmoud
2019 ◽  
Vol 101-B (6_Supple_B) ◽  
pp. 123-126 ◽  
Author(s):  
M. El-Husseiny ◽  
B. Masri ◽  
C. Duncan ◽  
D. S. Garbuz

AimsWe investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores.Patients and MethodsWe retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.ResultsAt ten years, the Kaplan–Meier survivorship for dislocation was 95.6% (95% confidence interval (CI) 90 to 98), with 101 patients at risk. At 20 years, the survivorship for dislocation was 90.6% (95% CI 81.0 to 95.5), with one patient at risk. Eight patients (7.2%) had a dislocation of their constrained liners. At ten years, the survival to any event was 89.4% (95% CI 82 to 93.8), with 96 patients at risk. At 20 years, the survival to any event was 82.5% (95% CI 71.9 to 89.3), with one patient at risk. Five hips (4.4%) had deep infection. Two patients (1.8%) developed dissociated constraining rings with pain but without dislocation, which required re-operation. Two patients (1.8%) had periprosthetic femoral fractures, without dislocation, that were treated by revision stems along with exchange of the well-functioning constrained liners.ConclusionConstrained tripolar liners used at revision hip arthroplasty provided favourable results in the long term for treatment of recurrent dislocation and for patients at high risk of dislocation. Cite this article: Bone Joint J 2019;101-B(6 Supple B):123–126.


2007 ◽  
Vol 22 (6) ◽  
pp. 849-858 ◽  
Author(s):  
Olivier Guyen ◽  
Vincent Pibarot ◽  
Gualter Vaz ◽  
Christophe Chevillotte ◽  
Jean-Paul Carret ◽  
...  

Prosthesis ◽  
2021 ◽  
Vol 3 (1) ◽  
pp. 53-60
Author(s):  
Giuseppe Solarino ◽  
Filippo Simone ◽  
Antonello Panella ◽  
Arianna Carlet ◽  
Flavia Riefoli ◽  
...  

Nowadays total hip arthroplasty (THA) is widely considered the operation of the century in orthopedic and traumatological fields. Despite this fact, instability and dislocation after THA are a common reason for revision surgery. The purpose of this prospective study is to evaluate the preliminary clinical and radiological results of a novel dual mobility cup. We evaluated 32 consecutive cases of patients who underwent THA using a novel dual mobility cup—with holes in the cup, a modular metallic inlay and a crosslinked polyethylene. All of them were considered at risk of instability of the implant due to primary or concomitant diagnosis. The preoperative Harris hip score was 54.7 on average. At a minimum 2 years follow-up, the mean HHS raised up to a mean value of 88.4; this improvement was statistically significant (p < 0.0001). None of the patients enrolled in this study sustained a postoperative dislocation at a mean follow-up of 39.6 months. Furthermore, no patients sustained modular liner dissociation or an intraprosthetic dislocation. As such, survivorship free from dislocation was 100% at both 2 and 5 years. This study demonstrates that the modular dual mobility (DM) socket provides dual articulation, larger jump distance, and greater range of motion before impingement, which significantly reduce the rate of dislocation.


2011 ◽  
Vol 12 (1) ◽  
Author(s):  
Noor Alolabi ◽  
Bashar Alolabi ◽  
Raman Mundi ◽  
Paul J Karanicolas ◽  
Jonathan D Adachi ◽  
...  

Sign in / Sign up