scholarly journals Comparative evaluation of use of a diode laser and electrode application with and without two dentinal tubule occluding agents in the management of dentinal hypersensitivity – A clinical study

2020 ◽  
Vol 24 (6) ◽  
pp. 535
Author(s):  
ChitraLaxmikant Patil ◽  
DilipGanpat Pol ◽  
RajeshPrabhakar Gaikwad
Author(s):  
Shaheen C ◽  
Preadeep Shukla ◽  
Gaurav Malhotra ◽  
Prerna Kataria ◽  
Mona Dagar

Background: the present study aims to evaluate whether fluoro calcium phospho silicate (Biomin or Elzenes) or in combination with Diode laser has better dentinal tubule occlusion and can be suggested as a effective treatment modality for patients with dentinal hypersensitivity. The objectives of the study were -to evaluate effectiveness of Fluoro calcium phospho silicate on dentinal tubules occlusion, to evaluate effectiveness of Fluoro calcium phospho silicate and laser and to compare its effect with Fluoro calcium phosphosilicate alone and laser on dentinal tubule occlusion, and to evaluate the effectiveness of laser on dentinal tubule occlusion. In study setting, SEM analysis was done at Sophisticated test and instrumentation centre, Cochin University of Science and Technology (CUSAT), Kerala. 120 Dentine specimens were obtained from sound premolars extracted for orthodontic purpose from the patients of age group 13 to 40 years. All the teeth were stored in 0. 2% thymol at room temperature. In our study, Fluoro calcium phospho silicate (Biomin) showed an average results of 70.37% completely occluded tubules and 23.48% of partially occluded tubules compared to 2.68% and 28.43% in the control group. Conclusion: In our invitro study the treated groups the specimens brushed with combination group (Biomin and Laser) showed the highest percentage of tubule occlusion followed by Biomin alone and then Laser. Hence from the results, it can be stated that combination of Biomin and laser can be considered as the best effective method in office treatment modality for dentinal hypersensitivity because of its ability to occlude more tubules.. Keywords: Diode laser, Biomin or Elzenes


2013 ◽  
Vol 7 (2) ◽  
pp. 66 ◽  
Author(s):  
Rajeev Ranjan ◽  
KausarJaha Yadwad ◽  
VarunB Bhatia ◽  
P Mahantesha ◽  
SudhirR Patil ◽  
...  

Author(s):  
S David ◽  
M Tielemans ◽  
D Heysselaer ◽  
M Hadeiba ◽  
E Rasca ◽  
...  

2018 ◽  
Vol 8 (3) ◽  
pp. 110
Author(s):  
Bhavana Puvvalla ◽  
Suchetha Aghanashini ◽  
Sapna Nadiger ◽  
DarshanB Mundinamanae ◽  
Divya Bhat ◽  
...  

Author(s):  
Anupama Ahirwar ◽  
Anuj Bhargava ◽  
Sanjesh Kumar Meena

Introduction: Dentinal Hypersensitivity (DH) presents as a short, intense pain emanating from exposed dentinal tubules. Many studies have concluded that mechanical, chemical or both factors increase the frequency of DH. Sealing of exposed dentinal tubule can be achieved with the use of Dental adhesives, restorations, Desensitising Agents (DA) and Lasers, each having their own mechanism of action. Aim: This clinical study was done to evaluate the efficacy of Hydroxy Methacrylate (HEMA) based DA and 980 nm diode laser in the treatment of DH. Materials and Methods: This two-arm parallel design split-mouth study was conducted on 30 adult patients attending the Dental Outpatient Clinic of Gandhi Medical College, Bhopal during the year December 2018 to January 2020 with clinically diagnosed high cervical DH (Charlie=3) occurring bilaterally in maxillary canine teeth. Scoring of baseline and postoperative DH was done utilising using Modified U.S. Public Health Service Criteria for DH Assessment. After recording the pretreatment baseline scores, mouth of each sample subject was divided bilaterally using split-mouth technique into Group A and Group B. The left side of patient’s mouth was designated as Group A in which a 10 W Diode Laser (980 nm) was used and right side of the patient’s mouth was classified as Group B, in which Shield Active (HEMA based) DA was used. The sensitivity score for both the groups was assessed immediately after application, after 24 hours, after seven days and after 21 days. Statistical Analysis was done by using Statistical Package for Social Sciences(SPSS) software version 22.0. Student’s t-test and repeated measures of ANOVA Test were applied. The p-value of less than 0.05 was considered statistically significant. Results: There was a statistically highly significant difference in sensitivity scores between both groups immediately after treatment p=0.038, after 24 hours, seven days and after 21 days. (p<0.001) depicting high efficacy of Diode lasers over DA. Repeated Measure of ANOVA was applied to find difference in mean score from baseline to 21 days. Immediately after application the results in Group A compared to baseline were statistically highly significant (p<0.001) and statistically significant in Group B (p<0.05). However, overall difference after 21 days compared to baseline were not significant in any group (p>0.05) depicting that the effect of both the desensitising therapies were not significant beyond 21 days in both the groups. Conclusion: Within the limits of this study, it can be concluded that both HEMA based DA and 980 nm diode laser were effective desensitisation treatment modalities for achieving immediate reduction of high cervical dentin hypersensitivity from baseline. Further, 980 nm Diode laser was found to be more efficacious and effective treatment option than HEMA based DA for treatment of DH.


Sign in / Sign up

Export Citation Format

Share Document