scholarly journals Adjacent Segment Degeneration after Single-Level PLIF: Comparison between Spondylolytic Spondylolisthesis, Degenerative Spondylolisthesis and Spinal Stenosis

2011 ◽  
Vol 5 (2) ◽  
pp. 82 ◽  
Author(s):  
Chang Hun Yu ◽  
Jung Eun Lee ◽  
Jae Jun Yang ◽  
Bong-Soon Chang ◽  
Choon-Ki Lee
2020 ◽  
pp. 1-6
Author(s):  
Ping-Guo Duan ◽  
Praveen V. Mummaneni ◽  
Jeremy M. V. Guinn ◽  
Joshua Rivera ◽  
Sigurd H. Berven ◽  
...  

OBJECTIVEThe aim of this study was to investigate whether fat infiltration of the lumbar multifidus (LM) muscle affects revision surgery rates for adjacent-segment degeneration (ASD) after L4–5 transforaminal lumbar interbody fusion (TLIF) for degenerative spondylolisthesis.METHODSA total of 178 patients undergoing single-level L4–5 TLIF for spondylolisthesis (2006 to 2016) were retrospectively analyzed. Inclusion criteria were a minimum 2-year follow-up, preoperative MR images and radiographs, and single-level L4–5 TLIF for degenerative spondylolisthesis. Twenty-three patients underwent revision surgery for ASD during the follow-up. Another 23 patients without ASD were matched with the patients with ASD. Demographic data, Roussouly curvature type, and spinopelvic parameter data were collected. The fat infiltration of the LM muscle (L3, L4, and L5) was evaluated on preoperative MRI using the Goutallier classification system.RESULTSA total of 46 patients were evaluated. There were no differences in age, sex, BMI, or spinopelvic parameters with regard to patients with and those without ASD (p > 0.05). Fat infiltration of the LM was significantly greater in the patients with ASD than in those without ASD (p = 0.029). Fat infiltration was most significant at L3 in patients with ASD than in patients without ASD (p = 0.017). At L4 and L5, there was an increasing trend of fat infiltration in the patients with ASD than in those without ASD, but the difference was not statistically significant (p = 0.354 for L4 and p = 0.077 for L5).CONCLUSIONSFat infiltration of the LM may be associated with ASD after L4–5 TLIF for spondylolisthesis. Fat infiltration at L3 may also be associated with ASD at L3–4 after L4–5 TLIF.


2018 ◽  
Vol 29 (4) ◽  
pp. 407-413 ◽  
Author(s):  
Ming-Kai Hsieh ◽  
Fu-Cheng Kao ◽  
Wen-Jer Chen ◽  
I-Jung Chen ◽  
Sheng-Fen Wang

OBJECTIVESpinopelvic parameters, such as the pelvic incidence (PI) angle, sacral slope angle, and pelvic tilt angle, are important anatomical indices for determining the sagittal curvature of the spine and the individual variability of the lumbar lordosis (LL) curve. The aim of this study was to investigate the influence of spinopelvic parameters and LL on adjacent-segment degeneration (ASD) after short lumbar and lumbosacral fusion for single-level degenerative spondylolisthesis.METHODSThe authors retrospectively reviewed the records of all short lumbar and lumbosacral fusion surgeries performed between August 2003 and July 2010 for single-level degenerative spondylolisthesis in their orthopedic department.RESULTSA total of 30 patients (21 women and 9 men, mean age 64 years) with ASD after lower lumbar or lumbosacral fusion surgery comprised the study group. Thirty matched patients (21 women and 9 men, mean age 63 years) without ASD comprised the control group, according to the following matching criteria: same diagnosis on admission, similar pathologic level (≤ 1 level difference), similar sex, and age. The average follow-up was 6.8 years (range 5–8 years). The spinopelvic parameters had no significant influence on ASD after short spinal fusion.CONCLUSIONSNeither the spinopelvic parameters nor a mismatch of PI and LL were significant factors responsible for ASD after short spinal fusion due to single-level degenerative spondylolisthesis.


2021 ◽  
Vol 34 (1) ◽  
pp. 83-88
Author(s):  
Ping-Guo Duan ◽  
Praveen V. Mummaneni ◽  
Minghao Wang ◽  
Andrew K. Chan ◽  
Bo Li ◽  
...  

OBJECTIVEIn this study, the authors’ aim was to investigate whether obesity affects surgery rates for adjacent-segment degeneration (ASD) after transforaminal lumbar interbody fusion (TLIF) for spondylolisthesis.METHODSPatients who underwent single-level TLIF for spondylolisthesis at the University of California, San Francisco, from 2006 to 2016 were retrospectively analyzed. Inclusion criteria were a minimum 2-year follow-up, single-level TLIF, and degenerative lumbar spondylolisthesis. Exclusion criteria were trauma, tumor, infection, multilevel fusions, non-TLIF fusions, or less than a 2-year follow-up. Patient demographic data were collected, and an analysis of spinopelvic parameters was performed. The patients were divided into two groups: mismatched, or pelvic incidence (PI) minus lumbar lordosis (LL) ≥ 10°; and balanced, or PI-LL < 10°. Within the two groups, the patients were further classified by BMI (< 30 and ≥ 30 kg/m2). Patients were then evaluated for surgery for ASD, matched by BMI and PI-LL parameters.RESULTSA total of 190 patients met inclusion criteria (72 males and 118 females, mean age 59.57 ± 12.39 years). The average follow-up was 40.21 ± 20.42 months (range 24–135 months). In total, 24 patients (12.63% of 190) underwent surgery for ASD. Within the entire cohort, 82 patients were in the mismatched group, and 108 patients were in the balanced group. Within the mismatched group, adjacent-segment surgeries occurred at the following rates: BMI < 30 kg/m2, 2.1% (1/48); and BMI ≥ 30 kg/m2, 17.6% (6/34). Significant differences were seen between patients with BMI ≥ 30 and BMI < 30 (p = 0.018). A receiver operating characteristic curve for BMI as a predictor for ASD was established, with an AUC of 0.69 (95% CI 0.49–0.90). The optimal BMI cutoff value determined by the Youden index is 29.95 (sensitivity 0.857; specificity 0.627). However, in the balanced PI-LL group (108/190 patients), there was no difference in surgery rates for ASD among the patients with different BMIs (p > 0.05).CONCLUSIONSIn patients who have a PI-LL mismatch, obesity may be associated with an increased risk of surgery for ASD after TLIF, but in obese patients without PI-LL mismatch, this association was not observed.


2014 ◽  
Vol 20 (5) ◽  
pp. 538-541 ◽  
Author(s):  
Shinya Okuda ◽  
Takenori Oda ◽  
Ryoji Yamasaki ◽  
Takafumi Maeno ◽  
Motoki Iwasaki

One of the most important sequelae affecting long-term results is adjacent-segment degeneration (ASD) after posterior lumbar interbody fusion (PLIF). Although several reports have described the incidence rate, there have been no reports of repeated ASD. The purpose of this report was to describe 1 case of repeated ASD after PLIF. A 62-year-old woman with L-4 degenerative spondylolisthesis underwent PLIF at L4–5. At the second operation, L3–4 PLIF was performed for L-3 degenerative spondylolisthesis 6 years after the primary operation. At the third operation, L2–3 PLIF was performed for L-2 degenerative spondylolisthesis 1.5 years after the primary operation. Vertebral collapse of L-1 was detected 1 year after the third operation, and the collapse had progressed. At the fourth operation, 3 years after the third operation, vertebral column resection of L-1 and replacement of titanium mesh cages with pedicle screw fixation between T-4 and L-5 was performed. Although the patient's symptoms resolved after each operation, the time between surgeries shortened. The sacral slope decreased gradually although each PLIF achieved local lordosis at the fused segment.


2007 ◽  
Vol 22 (1) ◽  
pp. 1-11 ◽  
Author(s):  
Paul McAfee ◽  
Larry T. Khoo ◽  
Luiz Pimenta ◽  
Andy Capuccino ◽  
Domagoj Coric ◽  
...  

Object Total disc replacement is an alternative to lumbar fusion, but patients with spinal stenosis, spondylolisthesis, and facet arthropathy are often excluded from this procedure because increased adjacent-segment motion can exacerbate dorsal spondylotic changes. In such cases of degenerative spondylolisthesis with stenosis, decompression and fusion remain the gold standard of treatment. To avoid attendant loss of motion at the treated segment, the TOPS system is a novel total posterior arthroplasty prosthesis that allows for an alternative dynamic, multiaxial, three-column stabilization and motion preservation. The purpose of this study is to report preliminary surgical data and clinical outcomes in patients treated with the TOPS lumbar total posterior arthroplasty system. Methods Twenty-nine patients were enrolled in a nonrandomized, multicenter, prospective pilot study outside the US. All patients had spinal stenosis and/or spondylolisthesis at L4–5 due to facet arthropathy. Radiographs and scores on outcome measures including the visual analog scale (VAS) for pain, Oswestry Disability Index (ODI), Short Form-36, and Zurich Claudication Questionnaire were prospectively recorded before surgery and at 6-week, 3-month, 6-month, and 1-year intervals after surgery. Prior to instrumentation, a bilateral total facetectomy and laminectomy at L4–5 or L3–4 was performed via a standard midline posterior approach. After decompression, the TOPS screws were inserted into four pedicles to achieve maximal purchase with triangulating bicortical trajectories. An appropriately sized TOPS arthroplasty implant was then applied. The mean surgical time was 3.1 hours, and patients' clinical status improved significantly following treatment with the TOPS device. The mean ODI score decreased compared with baseline by 41% at 1 year, and the 100-mm VAS score declined by 76 mm over the same time period. Radiographic analysis showed that lumbar motion was maintained, disc height was preserved, and no evidence of screw loosening was found. No device malfunctions or migrations and no device-related adverse events were reported during the study. Conclusions The TOPS total posterior arthroplasty system represents a novel, dynamic, posterior arthroplasty device that provides multiaxial stability in flexion, extension, rotation, and lateral bending after total facetectomy and neural decompression. The surgical data indicate that it can be safely applied via a traditional approach with low surgical morbidity and excellent 1-year functional and radiographic outcomes in patients with degenerative spondylolisthesis accompanied by stenosis and back pain.


2007 ◽  
Vol 22 (1) ◽  
pp. 1-11 ◽  
Author(s):  
Paul McAfee ◽  
Larry T. Khoo ◽  
Luiz Pimenta ◽  
Andy Capuccino ◽  
Domagoj Coric ◽  
...  

Object Total disc replacement is an alternative to lumbar fusion, but patients with spinal stenosis, spondylolisthesis, and facet arthropathy are often excluded from this procedure because increased adjacent-segment motion can exacerbate dorsal spondylotic changes. In such cases of degenerative spondylolisthesis with stenosis, decompression and fusion remain the gold standard of treatment. To avoid attendant loss of motion at the treated segment, the TOPS system is a novel total posterior arthroplasty prosthesis that allows for an alternative dynamic, multiaxial, three-column stabilization and motion preservation. The purpose of this study is to report preliminary surgical data and clinical outcomes in patients treated with the TOPS lumbar total posterior arthroplasty system. Methods Twenty-nine patients were enrolled in a nonrandomized, multicenter, prospective pilot study outside the US. All patients had spinal stenosis and/or spondylolisthesis at L4–5 due to facet arthropathy. Radiographs and scores on outcome measures including the visual analog scale (VAS) for pain, Oswestry Disability Index (ODI), Short Form-36, and Zurich Claudication Questionnaire were prospectively recorded before surgery and at 6-week, 3-month, 6-month, and 1-year intervals after surgery. Prior to instrumentation, a bilateral total facetectomy and laminectomy at L4–5 or L3–4 was performed via a standard midline posterior approach. After decompression, the TOPS screws were inserted into four pedicles to achieve maximal purchase with triangulating bicortical trajectories. An appropriately sized TOPS arthroplasty implant was then applied. The mean surgical time was 3.1 hours, and patients' clinical status improved significantly following treatment with the TOPS device. The mean ODI score decreased compared with baseline by 41% at 1 year, and the 100-mm VAS score declined by 76 mm over the same time period. Radiographic analysis showed that lumbar motion was maintained, disc height was preserved, and no evidence of screw loosening was found. No device malfunctions or migrations and no device-related adverse events were reported during the study. Conclusions The TOPS total posterior arthroplasty system represents a novel, dynamic, posterior arthroplasty device that provides multiaxial stability in flexion, extension, rotation, and lateral bending after total facetectomy and neural decompression. The surgical data indicate that it can be safely applied via a traditional approach with low surgical morbidity and excellent 1-year functional and radiographic outcomes in patients with degenerative spondylolisthesis accompanied by stenosis and back pain.


Sign in / Sign up

Export Citation Format

Share Document