scholarly journals Development of a Fast and Facile Analytical Approach to Quantify Radiometabolites in Human Plasma Samples Using Ultra High Performance Liquid Chromatography

2019 ◽  
Vol 10 (05) ◽  
pp. 185-201 ◽  
Author(s):  
Cécile Malherbe ◽  
Rudy Bidault ◽  
Claude Netter ◽  
Denis Guilloteau ◽  
Johnny Vercouillie ◽  
...  
Nanomedicine ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. 323-333
Author(s):  
Neda Mohamadi ◽  
Fariba Sharififar ◽  
Mostafa Pournamdari ◽  
Mehdi Ansari

Aim: To develop a novel method for the bioanalytical extraction of trigonelline (TRG) from human plasma samples using a magnetic nanocomposite and to evaluate its pharmacokinetic profile. Materials & methods: Magnetic bentonite/β-cyclodextrine (β-CD) nanoparticles, coupled with a validated ion-pairing reversed-phase high-performance liquid chromatography method, were used to determine TRG concentration from plasma samples following a single oral administration. Results: The developed reversed-phase high-performance liquid chromatography method was accurate, precise, specific, selective and reproducible. TRG showed rapid absorption, middle rate of elimination and mean residence time of ∼24 h. The data were best fitted on a two-compartment model in which tmax was 1.0 h, Cmax 0.115 μg/ml, area under the curve (AUC)0–24 1.72 μg/ml.h, Cl 0.0293 l/h/kg, t1/2α 0.79 h, t1/2β 13.68 h and ka 1.63 h-1. Conclusion: The findings of this study could provide useful information to promote the future study of TRG and aid optimal dose finding.


2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


Sign in / Sign up

Export Citation Format

Share Document