scholarly journals Experimental Study on Indoor Thermal Stratification in Large Space by under Floor Air Distribution System (UFAD) in Summer

Engineering ◽  
2011 ◽  
Vol 03 (04) ◽  
pp. 384-388 ◽  
Author(s):  
Xin Wang ◽  
Chen Huang ◽  
Weiwu Cao ◽  
Xuelei Gao ◽  
Wen Liu
Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 8130
Author(s):  
Ziwen Dong ◽  
Liting Zhang ◽  
Yongwen Yang ◽  
Qifen Li ◽  
Hao Huang

Stratified air distribution systems are commonly used in large space buildings. The research on the airflow organization of stratified air conditioners is deficient in terms of the analysis of multivariable factors. Moreover, studies on the coupled operation of stratified air conditioners and natural ventilation are few. In this paper, taking a Shanghai Airport Terminal departure hall for the study, air distribution and thermal comfort of the cross-section at a height of 1.6 m are simulated and compared under different working conditions, and the effect of natural ventilation coupling operation is studied. The results show that the air distribution is the most uniform and the thermal comfort is the best (predicted mean vote is 0.428, predicted percentage of dissatisfaction is 15.2%) when the working conditions are 5.9% air supply speed, 11 °C cooling temperature difference and 0° air supply angle. With the coupled operation of natural ventilation, the thermal comfort can be improved from Grade II to Grade I.


2017 ◽  
Vol 112 ◽  
pp. 613-620 ◽  
Author(s):  
Ilinca Nastase ◽  
Cristiana Croitoru ◽  
Mircea Dan ◽  
Ioan Ursu ◽  
Amina Meslem

Author(s):  
Neil Stephen Lopez ◽  
Selena Kay Galeos ◽  
Brian Raphael Calderon ◽  
David Roy Dominguez ◽  
Bryan Joseph Uy ◽  
...  

Author(s):  
Wei Bing ◽  
Li Li ◽  
Jiang Lu ◽  
Zhang Wei

At present all cold air distribution systems are being used widely due to their advantages of smaller ductwork, shorter floor-to-floor height and less energy consumption etc. They are mostly used in VAV (Variable Air Volume) systems or with the radiant panel systems in the office and residential buildings at the supply air dew point temperature of 6∼10°C, rarely used in large space buildings. The technology of stratified air conditioning is one of the energy saving technologies to large space buildings, which has been popularly used in the conventional air supply systems with the supply air dew point temperature of 11∼16°C. In this paper, the cold air distribution system and the stratified air conditioning technology in a large space building are combined to study. With the method of CFD, the indoor thermal environment of a large space workshop is simulated. The velocity and the temperature as well as the relative humidity fields under different air flow modes are presented, analyzed and compared. With the help of numerical simulation results, the optimal airflow mode is proposed, which show that the all cold air distribution with the stratified air conditioning is a good option for large space buildings. All these above will be good references to the application of cold air distribution system and the selection of the airflow mode in large space buildings.


Sign in / Sign up

Export Citation Format

Share Document