scholarly journals Application of electromagnetic and electrical resistivity methods for foundation studies at Ahmadu Bello University Phase II, Zaria

2020 ◽  
Vol 12 (1) ◽  
pp. 57-62
Author(s):  
L.A. Olayinka ◽  
B.G. Aremu ◽  
A.L. Ahmed ◽  
K.M. Lawal

Very Low-Frequency Electromagnetic (VLF-EM) and 2D electrical resistivity survey were carried out at the Ahmadu Bello University Phase II in order to investigate the suitability of the soil materials for the foundation of super-structures in the study area. The Terra-Plus equipment and ABEM SAS 4000 were used for VLF-EM and resistivity data acquisition respectively. The VLF-EM Data were collected along five (5) profiles at station interval of 10 m along each profile. The data collected from each of the VLF-EM profile were processed and interpreted with the aid of Karous-Hjelt and Fraser filter software. Electrical resistivity profile was laid on the weak zones revealed by the 2D VLF-EM profiles through the aid of dipole-dipole configuration. The data obtained were processed and interpreted with the aid of Res2Dinv software. Borehole log of the study area was used as additional information which serves as a calibration tool. The 2D imaging profile of VLF-EM highly correlates with resistivity profile. The 2D VLF-EM and resistivity profiles revealed the conductive zone and resistive zones. These zones are suspected to be geological features (dyke, faults and fractures). This geological feature such as fracture zones was filled with an earth’s materials which are probably sandy clay and mottled clay, and these materials are highly undesirable for the foundation of building structures due to its characteristics of swelling and contracting during rainy and dry season respectively. Thus, undesirable materials should be excavated and be refilled with suitable materials for the foundation of super-structures and also, geological bodies should be avoided when the foundation of the structures is to be erected. Keyword: VLF-EM, electrical resistivity, foundation of super-structures, geological feature, undesirable materials  

2017 ◽  
Vol 2 (2) ◽  
Author(s):  
Olaide S Hammed ◽  
Wilfred N Igboama ◽  
M O Awoyemi ◽  
Julius O Fatoba ◽  
Morufu Aroyehun ◽  
...  

Electrical Resistivity survey was carried out with the aim of identifying the degree of soil corrosion associated with the sub soil of the Federal University Oye Ekiti phase II. The sub soil resistivity of the area was surveyed and evaluated using Ohmega resistivity meter. The sub soil resistivity parameters were used to delineate the degree of the sub soil corrosion. Four electrodes were inserted into the soil/rock using the Wenner profiling, vertical electrical sounding and Dipole- Dipole array along the traverses with a spacing of 5m and n =1 to 5.In this method, artificially generated electric current(I) was injected into the ground via two current electrodes while the resulting potential difference (V) is measured by another pair of electrodes. The survey revealed that the Southwest and Northwest regions of the study area were associated with high resistivity (200-500 Ω-m).This implies that the soil structure of the region is not corrosive, while the southeast region was associated with low resistivity (20-80 Ω-m) value which implies that the sub soil structure is corrosive. The degree of corrosion increases from the western to eastern part of the study area which may be due to bedrock topography. Of all the layers investigated, the topsoil layer is highly corrosive compare to other layers.


2016 ◽  
Vol 34 (1) ◽  
Author(s):  
Walter Sydney Dutra Folly ◽  
Aracy Sousa Senra

ABSTRACT. We describe the construction and testing of a simple and efficient low-cost resistivimeter designed for use in practical classes in Applied Geophysics. The equipment was successfully tested in a vertical electrical sounding (VES) performed on sandy terrain within the campus of the Universidade Federal de Sergipe, Brazil. The VES results were in good agreement with the profiles obtained from two boreholes located approximately 500 m from the test area, clearly demonstrating the efficiency of the equipment and the adopted methodology.Keywords: vertical electrical sounding, electrical resistivity, resistivity profile. RESUMO. Neste artigo, descrevemos a construção e o teste de um resistivímetro de baixo custo, simples e eficiente, concebido para ser utilizado em aulas práticas de Geofísica Aplicada. O equipamento foi testado com a realização de uma sondagem elétrica vertical (SEV) em um terreno arenoso localizado no campus da Universidade Federal de Sergipe, Brasil. Os resultados obtidos nesta SEV apresentaram boa concordância com os perfis observados em dois poços de sondagem localizados a 500 m da área de teste, fato que comprovou a eficiência do equipamento e da metodologia adotada.Palavras-chave: sondagem elétrica vertical, resistividade elétrica, perfil de resistividade. 


2021 ◽  
Vol 14 (4) ◽  
Author(s):  
Muhammad Waqar Azeem ◽  
Khaista Rehman ◽  
Nazeer Ur Rehman ◽  
Afrasiab ◽  
Umar Farooq ◽  
...  

2005 ◽  
Vol 83 (2) ◽  
pp. 173-193 ◽  
Author(s):  
A. Samouëlian ◽  
I. Cousin ◽  
A. Tabbagh ◽  
A. Bruand ◽  
G. Richard