scholarly journals A Case of Type A Acute Aortic Dissection in an Elderly Woman with Immune Thrombocytopenia Who Underwent Replacement of the Ascending Aorta and Aortic Arch and Later Required Aortic Root Replacement for Redissection of the Aortic Root

2016 ◽  
Vol 45 (1) ◽  
pp. 57-61
Author(s):  
Takanori Kono ◽  
Toru Takaseya ◽  
Satoshi Kikusaki ◽  
Keishi Hashimoto ◽  
Yuichiro Hirata ◽  
...  
2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Eden C. Payabyab ◽  
Jonathan M. Hemli ◽  
Allan Mattia ◽  
Alex Kremers ◽  
Sohrab K. Vatsia ◽  
...  

Abstract Background Direct cannulation of the innominate artery for selective antegrade cerebral perfusion has been shown to be safe in elective proximal aortic reconstructions. We sought to evaluate the safety of this technique in acute aortic dissection. Methods A multi-institutional retrospective review was undertaken of patients who underwent proximal aortic reconstruction for Stanford type A dissection between 2006 and 2016. Those patients who had direct innominate artery cannulation for selective antegrade cerebral perfusion were selected for analysis. Results Seventy-five patients underwent innominate artery cannulation for ACP for Stanford Type A Dissections. Isolated replacement of the ascending aorta was performed in 36 patients (48.0%), concomitant aortic root replacement was required in 35 patients (46.7%), of whom 7 had a valve-sparing aortic root replacement, ascending aorta and arch replacement was required in 4 patients (5%). Other procedures included frozen elephant trunk (n = 11 (14.7%)), coronary artery bypass grafting (n = 20 (26.7%)), and peripheral arterial bypass (n = 4 (5.3%)). Mean hypothermic circulatory arrest time was 19 ± 13 min. Thirty-day mortality was 14.7% (n = 11). Perioperative stroke occurred in 7 patients (9.3%). Conclusions This study is the first comprehensive review of direct innominate artery cannulation through median sternotomy for selective antegrade cerebral perfusion in aortic dissection. Our experience suggests that this strategy is a safe and effective technique compared to other reported methods of cannulation and cerebral protection for delivering selective antegrade cerebral perfusion in these cases.


2001 ◽  
Vol 71 (3) ◽  
pp. 282-286
Author(s):  
Ovidiu Stiru ◽  
Roxana Carmen Geana ◽  
Adrian Tulin ◽  
Raluca Gabriela Ioan ◽  
Victor Pavel ◽  
...  

The purpose of this case presentation is to present a simplified surgical technique when in a patient with acute aortic dissection type A (AAD), aortic arch, and ascending aorta is completely replaced without circulatory arrest. A 67-year old male was presented in our institution with severe chest and back pain at 12 h after the onset of the symptoms. Imaging studies by 3D contrast-enhanced thoracic computed tomography (CT-scan) and transesophageal echocardiography (TEE) revealed ascending aortic dissection towards the aortic arch, which was extending in the proximal descending aorta. We practiced emergency median sternotomy and established cardiopulmonary bypass (CBP) between the right atrium and the right femoral artery with successive cross-clamping of the ascending and descending aorta below the origin of the left subclavian artery (LSA). In normothermic condition without circulatory arrest and with antegrade cerebral perfusion, we replaced the ascending aorta and aortic arch with a four branched Dacron graft. Patient evolution was uneventful, and he was discharged, after fourteen days from the hospital. At a one-year follow-up, 3D CT-scan showed no residual dissection with a well-circulated lumen of the supra-aortic arteries. Using the described surgical approach, CPB was not interrupted, the brain was protected, and hypothermia was no used. This approach made these surgical procedures shorter, and known complications of hypothermia and circulatory arrest are avoided.Acute aortic dissection aortic type A, total arch replacement, normothermia


2020 ◽  
Author(s):  
Eden C Payabyab ◽  
Jonathan M. Hemli ◽  
Allan Mattia ◽  
Alex Kremers ◽  
Sohrab K. Vatsia ◽  
...  

Abstract Background: Direct cannulation of the innominate artery for selective antegrade cerebral perfusion has been shown to be safe in elective proximal aortic reconstructions. We sought to evaluate the safety of this technique in acute aortic dissection. Methods: A multi-institutional retrospective review was undertaken of patients who underwent proximal aortic reconstruction for Stanford type A dissection between 2006 and 2016. Those patients who had direct innominate artery cannulation for selective antegrade cerebral perfusion were selected for analysis. Results: Seventy-five patients underwent innominate artery cannulation for ACP for Stanford Type A Dissections. Isolated replacement of the ascending aorta was performed in 36 patients (48.0%), concomitant aortic root replacement was required in 35 patients (46.7%), of whom 7 had a valve-sparing aortic root replacement, ascending aorta and arch replacement was required in 4 patients (5%). Other procedures included frozen elephant trunk (n = 11 (14.7%)), coronary artery bypass grafting (n = 20 (26.7%)), and peripheral arterial bypass (n = 4 (5.3%)). Mean hypothermic circulatory arrest time was 19 ± 13 minutes. Thirty-day mortality was 14.7% (n = 11). Perioperative stroke occurred in 7 patients (9.3%).Conclusions: This study is the first comprehensive review of direct innominate artery cannulation through median sternotomy for selective antegrade cerebral perfusion in aortic dissection. Our experience suggests that this strategy is a safe and effective technique compared to other reported methods of cannulation and cerebral protection for delivering selective antegrade cerebral perfusion in these cases.


2011 ◽  
Vol 14 (6) ◽  
pp. 373 ◽  
Author(s):  
Saina Attaran ◽  
Maria Safar ◽  
Hesham Zayed Saleh ◽  
Mark Field ◽  
Manoj Kuduvalli ◽  
...  

<p>Management of acute Stanford type A aortic dissection remains a major surgical challenge. Directly cannulating the ascending aorta provides a rapid establishment of cardiopulmonary bypass but consists of risks such as complete rupture of the aorta, false lumen cannulation, subsequent malperfusion and propagation of the dissection.</p><p>We describe a technique of cannulating the ascending aorta in patients with acute aortic dissection that can be performed rapidly in hemodynamically unstable patients under ultrasound-epiaortic and transesophageal (TEE) guidance.</p>


2021 ◽  
Vol 104 (4) ◽  
pp. 604-609

Background: The choice of arterial inflow for acute Stanford type A aortic dissection repair remains controversial. The axillary artery should be considered as first choice for cannulation, but this technique is time-consuming. The ascending aortic cannulation provides antegrade perfusion and can be performed rapidly but there are several concerns such as aortic rupture, extension of dissection, and false lumen cannulation. Objective: To compare the establishment time of cardiopulmonary bypass (CPB) and postoperative outcomes of the two cannulation techniques that provide antegrade perfusion, which was direct true lumen cannulation on the dissected ascending aorta using epiaortic ultrasound-guided and axillary artery cannulation in Siriraj Hospital. Materials and Methods: The authors retrospectively reviewed all the 30 cases of acute aortic dissection type A using two different cannulation methods performed between February 2011 and May 2017. Direct true lumen ascending aortic cannulation was performed using the epiaortic ultrasound-guide with Seldinger technique in 12 patients, and axillary artery cannulation was performed in 18 patients. Results: The direct true lumen ascending aortic cannulation was safely performed in all patients. None of them had aortic rupture. Skin incision to CPB time was significantly faster in the epiaortic ultrasound-guided ascending aortic cannulation group at 29±8 versus 49±14 minutes (p<0.001). The 30-day mortality and postoperative adverse events, such as ischemic stroke, acute kidney injury, visceral organ and limb malperfusion showed no statistically significant difference from the axillary artery cannulation method. Conclusion: Epiaortic ultrasound-guided true lumen cannulation of ascending aorta in the treatment of acute aortic dissection type A is safe and feasible. Skin incision to CPB time can be performed faster and provided good outcome compared to the axillary artery cannulation technique. Keywords: Acute aortic dissection, Ascending cannulation, Epiaortic ultrasound


Sign in / Sign up

Export Citation Format

Share Document