Electric Power Transmission Distribution Line Operation Maintenance and Troubleshooting Technology

2021 ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 100-107
Author(s):  
E. M. Farhadzadeh ◽  
A. Z. Muradalyiev ◽  
S. A. Muradalyiev ◽  
A. A. Nazarov

The organization of operation, maintenance and repair of the basic technological facilities of electric power systems (EPS), which are beyond their designed service life (hereinafter referred to as ageing facilities, or AFs) is one of the problems that determine the energy security of many countries, including economically developed nations. The principal cause of insufficient overall performance of AFs is the traditional focus of the EPS management on economic efficiency and the insufficient attention to reliability and safety of AFs. The tendency to nonlinear growth in the frequency of occurrence of unacceptable consequences in the EPS requires ensuring the operational reliability and safety of AFs. The averaged estimates of reliability and safety used at designing power facilities are not suitable for characterization of overall operational performance. Among the basic and the least investigated (in terms of operational reliability and safety) EPS facilities are overhead power transmission lines (OPL) with a voltage of 110 кV and above. This is for a reason. OPL are electric power facilities with elements distributed along a multi-kilometer line (supports, insulators, wires, accessories, etc.). That is what makes the organization of continuous monitoring of the technical condition of each of these elements, and, consequently, the assessment of operational reliability and safety, so problematic. A method is suggested for assessment of “weak links” among the operated OPL on operative intervals of time along with a method for assessment of the technical condition of OPL at examination of a representative sample.


Author(s):  
M. А. Fursanov ◽  
A. A. Zalotoy

The issues of prospective operation of the city electric networks in the conditions of the MART GRID, which will be quite different as compared to the traditional understanding and approaches, are under consideration. This requires the selection and application of appropriate analytical criteria and approaches to assessment, analysis and control of the networks. With this regard the following criteria are recommended: in a particular case – the optimal (minimal) technological electric power consumption (losses), while in general – economically reasonable (minimal) cost value of electric power transmission. It should be also borne in mind that contemporary urban networks are actively saturated with distributed sources of small generation that have radically changed the structure of electrical networks; therefore, account for such sources is an absolutely necessary objective of management regimes of urban electric networks, both traditional and in associated with the SMART GRID. A case of the analysis and control of urban electric 10 kV networks with distributed small sources of generation has been developed and presented according to the theoretical criterion of minimum relative active power losses in the circuit as a control case. The conducted research makes it possible to determine the magnitude of the tolerance network mode from the point of the theoretical minimum. 


Sign in / Sign up

Export Citation Format

Share Document