scholarly journals A Novel Special-shaped Stylet Technique for Intubation with GlideScope® Video Laryngoscope Devices

2021 ◽  
Vol 6 (2) ◽  
pp. 57-60
Author(s):  
Tural Alekberli ◽  
Leslie Yarmush
Keyword(s):  
2021 ◽  
Vol 9 ◽  
pp. 2050313X2110158
Author(s):  
Daniel Gerber ◽  
Balthasar Eberle ◽  
Gabor Erdoes

Perioperative visual loss is a rare but severe complication after surgery in prone position. One of several mechanisms is direct ophthalmic compression. This can be avoided through optimal positioning and padding of the head, but position and integrity of the eyes need to be checked at regular intervals. We describe the use of a conventional video laryngoscope during vascular surgery in prone position as a simple solution for intermittent monitoring of external integrity of the eyes and size of the pupils. This requires no additional material and allows documentation of the findings. Our method might reduce complications and improve patient outcome.


Author(s):  
Jürgen Knapp ◽  
Bettina Eberle ◽  
Michael Bernhard ◽  
Lorenz Theiler ◽  
Urs Pietsch ◽  
...  

Abstract Background Tracheal intubation remains the gold standard of airway management in emergency medicine and maximizing safety, intubation success, and especially first-pass intubation success (FPS) in these situations is imperative. Methods We conducted a prospective observational study on all 12 helicopter emergency medical service (HEMS) bases of the Swiss Air Rescue, between February 15, 2018, and February 14, 2019. All 428 patients on whom out-of-hospital advanced airway management was performed by the HEMS crew were included. The C-MAC video laryngoscope was used as the primary device for tracheal intubation. Intubation procedures were recorded by the video laryngoscope and precise time points were recorded to verify the time necessary for each attempt and the overall procedure time until successful intubation. The videos were further analysed for problems and complications during airway management by an independent reviewer. Additionally, a questionnaire about the intubation procedure, basic characteristics of the patient, circumstances, environmental factors, and the provider’s level of experience in airway management was filled out. Main outcome measures were FPS of tracheal intubation, overall success rate, overall intubation time, problems and complications of video laryngoscopy. Results FPS rate was 87.6% and overall success rate 98.6%. Success rates, overall time to intubation, and subjective difficulty were not associated to the providers’ expertise in airway management. In patients undergoing CPR FPS was 84.8%, in trauma patients 86.4% and in non-trauma patients 93.3%. FPS in patients with difficult airway characteristics, facial trauma/burns or obesity ranges between 87 and 89%. Performing airway management indoors or inside an ambulance resulted in a significantly higher FPS of 91.1% compared to outdoor locations (p < 0.001). Direct solar irradiation on the screen, fogging of the lens, and blood on the camera significantly impaired FPS. Several issues for further improvements in the use of video laryngoscopy in the out-of-hospital setting and for quality control in airway management were identified. Conclusion Airway management using the C-MAC video laryngoscope with Macintosh blade in a group of operators with mixed experience showed high FPS and overall rates of intubation success. Video recording emergency intubations may improve education and quality control.


2020 ◽  
Vol 55 ◽  
pp. 101633
Author(s):  
Chung-Feng Jeffrey Kuo ◽  
Yu-Ching Li ◽  
Wei-Han Weng ◽  
Kathya Belen Pinos Leon ◽  
Yueng-Hsiang Chu

2015 ◽  
Vol 27 (2) ◽  
pp. 119-125 ◽  
Author(s):  
John Vassiliadis ◽  
Alex Tzannes ◽  
Kerry Hitos ◽  
Jessica Brimble ◽  
Toby Fogg

2011 ◽  
Vol 40 (4) ◽  
pp. 443-444 ◽  
Author(s):  
Fu-Shan Xue ◽  
He-Ping Liu ◽  
Jun Xiong ◽  
Xin-Ling Guo ◽  
Xu Liao

2012 ◽  
Vol 60 (6) ◽  
pp. 739-748 ◽  
Author(s):  
John C. Sakles ◽  
Jarrod Mosier ◽  
Stephen Chiu ◽  
Mari Cosentino ◽  
Leah Kalin

2015 ◽  
Vol 2015 ◽  
pp. 1-4
Author(s):  
Prerana N. Shah ◽  
Kaveri Das

Background. Video laryngoscopes provide better view and can improve ease of intubation compared with standard laryngoscopes. Methods. A prospective randomized study was done on 60 patients, 18 to 65 years old, comparing McGrath video laryngoscope and Macintosh laryngoscope. The aim was to compare the ease, efficacy, and usability of them during routine airway management. The primary endpoint was duration of intubation and the secondary endpoints were Cormack and Lehane grade of laryngoscopic view, number of intubation attempts, and incidence of complications. Results. There was an increase in total duration of intubation with McGrath video laryngoscope with 42.9 ± 19.5 seconds compared to Macintosh laryngoscope with 17.9 ± 4.6 seconds. In Macintosh group, 73.3% had grade I, 20% had grade II, and 6.7% had grade III Cormack Lehane view, while in McGrath group, 83.3% had grade I, 13.3% had grade II, and 3.3% had grade III. In McGrath group, 6 patients (20%) required more than 120 seconds to get intubated and only 73.3% were intubated in 1 attempt, while patients in Macintosh group had 100% successful intubation in 1 attempt. Pharyngeal trauma was seen with McGrath videolaryngoscopy. Conclusion. Duration of laryngoscopy, intubation, and total duration of intubation were significantly higher in McGrath group than in Macintosh group. McGrath group required a higher number of intubation attempts.


Sign in / Sign up

Export Citation Format