scholarly journals Preliminary results of linac-based radiosurgery in arteriovenous malformations and cerebral tumours in the Oncology Centre in Bydgoszcz

2013 ◽  
Vol 1 ◽  
pp. 29-33
Author(s):  
Paweł Sokal ◽  
Andrzej Lebioda ◽  
Maciej Harat ◽  
Jacek Furtak ◽  
Monika Grzela ◽  
...  
Neurosurgery ◽  
1982 ◽  
Vol 11 (6) ◽  
pp. 754-760 ◽  
Author(s):  
Victor Aldo Fasano ◽  
Rosa Urciuoli ◽  
Roberto Maria Ponzio

Abstract Six arteriovenous malformations (AVMs) and five arterial aneurysms (AAs) were treated with either argon or neodymium:yttrium-aluminum-garnet laser irradiation; one AVM was treated with both. All AVMs were occluded completely, leaving adjacent tissue untouched and preserving the regional vascularization. Photocoagulation produced varying effects on AAs: in one case an intraoperative rupture was sealed, in two cases the volume of an ectasia was reduced when the bleeding and thinner areas were coagulated, and in one case a saccular aneurysm was progressively and completely obliterated while the patency of the parent artery was preserved. These preliminary results are satisfactory; more experience will indicate how and when these new techniques can replace traditional ones or be used in combination with them.


2005 ◽  
Vol 11 (1_suppl) ◽  
pp. 159-164 ◽  
Author(s):  
L. Pierot ◽  
A. C. Januel ◽  
D. Herbreteau ◽  
X. Barreau ◽  
J. Drouineau ◽  
...  

The main final goal of the treatment of brain AVMs is to prevent bleeding and to obtain a complete occlusion of the nidus. The strategy of treatment of brain arteriovenous malformations (AVM) has to be defined by a multidisciplinary team and will usually combine several modalities (surgery, radiosurgery, embolization). Embolization is generally the first step of treatment. Occasionally embolization is able to completely occlude a small AVM. Otherwise embolization is the first step before surgery or radiosurgery. Several embolic agents have been proposed for embolization of brain AVMs like particles or cyanoacrylates. The main disadvantage of particles is the high frequency of recanalization. The cyanoacrylates are probably more appropriate, providing a permanent occlusion. However, due to the polymerizing characteristics of the glue, the time of injection is relatively short (few seconds or minutes) and a complete or substantial occlusion of the nidus is difficult to obtain, especially in the case of medium or largesized AVMs. Onyx is a nonadhesive liquid polymer made of a mixture of ethylene-vinyl-alcohol copolymer and dimethylsulfoxide. The theoretical advantage of a nonadhesive liquid is to eliminate the risk of gluing the microcatheter and subsequently to perform a more durable injection with a larger amounts of agent delivered in a single injection. Several French centers have undertaken a prospective, multicentric study to evaluate the clinical value of Onyx in embolization of brain AVMs. As required, 50 patients were included. Preliminary results are presented regarding the first 48 patients, the last 2 patients being included after writing of this paper. The treatment is now completed in 15 patients. As expected, it was possible with Onyx to perform long duration injections (5 to 70 minutes with a mean of 34 minutes). Volumes injected per session were also important (0.25 to 6 ml with a mean of 1.6 ml). According to the clinical experience of the centers, duration and volume injected were most important with Onyx than with cyanoacrylates. Out of the 15 patients for whom embolization is now completed, 14 had a percentage of occlusion of the nidus greater than 60% (with 2 complete occlusion).


1999 ◽  
Vol 173 ◽  
pp. 185-188
Author(s):  
Gy. Szabó ◽  
K. Sárneczky ◽  
L.L. Kiss

AbstractA widely used tool in studying quasi-monoperiodic processes is the O–C diagram. This paper deals with the application of this diagram in minor planet studies. The main difference between our approach and the classical O–C diagram is that we transform the epoch (=time) dependence into the geocentric longitude domain. We outline a rotation modelling using this modified O–C and illustrate the abilities with detailed error analysis. The primary assumption, that the monotonity and the shape of this diagram is (almost) independent of the geometry of the asteroids is discussed and tested. The monotonity enables an unambiguous distinction between the prograde and retrograde rotation, thus the four-fold (or in some cases the two-fold) ambiguities can be avoided. This turned out to be the main advantage of the O–C examination. As an extension to the theoretical work, we present some preliminary results on 1727 Mette based on new CCD observations.


2000 ◽  
Vol 179 ◽  
pp. 163-165
Author(s):  
S. K. Solanki ◽  
M. Fligge ◽  
P. Pulkkinen ◽  
P. Hoyng

AbstractThe records of sunspot number, sunspot areas and sunspot locations gathered over the centuries by various observatories are reanalysed with the aim of finding as yet undiscovered connections between the different parameters of the sunspot cycle and the butterfly diagram. Preliminary results of such interrelationships are presented.


1978 ◽  
Vol 48 ◽  
pp. 31-35
Author(s):  
R. B. Hanson

Several outstanding problems affecting the existing parallaxes should be resolved to form a coherent system for the new General Catalogue proposed by van Altena, as well as to improve luminosity calibrations and other parallax applications. Lutz has reviewed several of these problems, such as: (A) systematic differences between observatories, (B) external error estimates, (C) the absolute zero point, and (D) systematic observational effects (in right ascension, declination, apparent magnitude, etc.). Here we explore the use of cluster and spectroscopic parallaxes, and the distributions of observed parallaxes, to bring new evidence to bear on these classic problems. Several preliminary results have been obtained.


Author(s):  
Irwin Bendet ◽  
Nabil Rizk

Preliminary results reported last year on the ion etching of tobacco mosaic virus indicated that the diameter of the virus decreased more rapidly at 10KV than at 5KV, perhaps reaching a constant value before disappearing completely.In order to follow the effects of ion etching on TMV more quantitatively we have designed and built a second apparatus (Fig. 1), which incorporates monitoring devices for measuring ion current and vacuum as well as accelerating voltage. In addition, the beam diameter has been increased to approximately 1 cm., so that ten electron microscope grids can be exposed to the beam simultaneously.


Sign in / Sign up

Export Citation Format

Share Document