scholarly journals Effect of Carbonated Drinks on Uterine Development-An Experimental Study

BioMedica ◽  
2020 ◽  
Vol 36 (1) ◽  
pp. 23-29
Author(s):  
Dr Gong Zhuandi ◽  
Professor Wei Suocheng ◽  
Wei Limin ◽  
Liang Haoqin ◽  
Lai Luju
2017 ◽  
Vol 90 (3) ◽  
pp. 313-326
Author(s):  
Silvia Izabella Pop ◽  
Mircea Dudescu ◽  
Violeta Valentina Merie ◽  
Mariana Pacurar ◽  
Cristina Dana Bratu

Background and aims. This experimental study mainly aims at comparing the most important mechanical properties of the new orthodontic archwires, those immersed in fluorinated solution, the as-retrieved ones and  the intra-oral used ones.Methods. A total of 270 arch wires were tested, using tensile testing and three-point bending tests. The tested archwires were made of Stainless Steel, Nickel Titanium, Beta-Titanium and physiognomic covered Nickel Titanium. The tested archwires were subjected to three types of treatments: immersion into fluorinated solution, immersion into carbonated drinks and intra-oral use.Results. The immersion caused variations of the activation and deactivation forces of all arch wires. The most affected arch wires, in terms of bending characteristics,  were the intra-oral used ones.Conclusions. The alteration of mechanical properties of the orthodontic arch wires by their immersion into fluorinated solutions and soft drinks could not be statistically demonstrated.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


1962 ◽  
Vol 5 (4) ◽  
pp. 387-394 ◽  
Author(s):  
Bruce Quarrington ◽  
Jerome Conway ◽  
Nathan Siegel
Keyword(s):  

1974 ◽  
Vol 126 (2) ◽  
pp. 243-248
Author(s):  
A WAKABAYASHI ◽  
T KUBO ◽  
K CHARNEY ◽  
Y NAKAMURA ◽  
J CONNOLLY

1963 ◽  
Vol 45 (3) ◽  
pp. 374-383 ◽  
Author(s):  
Donald C. McIlrath ◽  
George A. Hallenbeck ◽  
Hubert A. Allen ◽  
Charles V. Mann ◽  
Edward J. Baldes ◽  
...  
Keyword(s):  

1958 ◽  
Vol 34 (1) ◽  
pp. 11-20 ◽  
Author(s):  
Henry D. Janowitz ◽  
Vernon A. Weinstein ◽  
Rhoda G. Shaer ◽  
James F. Cereghini ◽  
Franklin Hollander

Sign in / Sign up

Export Citation Format

Share Document