scholarly journals Results of the Novation CrowncupTM porous-coated uncemented acetabular component in total hip arthroplasty: a 10-year clinical and radiological assessment

2021 ◽  
Vol 55 (4) ◽  
pp. 311-315
Author(s):  
Daniel Godoy-Monzon ◽  
◽  
Agustin Garcia-Mansilla ◽  
Alberto Cid Casteulani ◽  
Santiago Svarzchtein ◽  
...  
Orthopedics ◽  
1996 ◽  
Vol 19 (2) ◽  
pp. 159-163
Author(s):  
Brian F Kavanagh ◽  
John J Callaghan ◽  
Robert Leggon ◽  
R David Heekin ◽  
Les Wold

Author(s):  
Joel Moktar ◽  
Alan Machin ◽  
Habiba Bougherara ◽  
Emil H Schemitsch ◽  
Radovan Zdero

This study provides the first biomechanical comparison of the fixation constructs that can be created to treat transverse acetabular fractures when using the “gold-standard” posterior versus the anterior approach with and without a total hip arthroplasty in the elderly. Synthetic hemipelvises partially simulating osteoporosis (n = 24) were osteotomized to create a transverse acetabular fracture and then repaired using plates/screws, lag screws, and total hip arthroplasty acetabular components in one of four ways: posterior approach (n = 6), posterior approach plus a total hip arthroplasty acetabular component (n = 6), anterior approach (n = 6), and anterior approach plus a total hip arthroplasty acetabular component (n = 6). All specimens were biomechanically tested. No differences existed between groups for stiffness (range, 324.6–387.3 N/mm, p = 0.629), clinical failure load at 5 mm of femoral head displacement (range, 1630.1–2203.9 N, p = 0.072), or interfragmentary gapping (range, 0.67–1.33 mm, p = 0.359). Adding a total hip arthroplasty acetabular component increased ultimate mechanical failure load for posterior (2904.4 vs. 3652.3 N, p = 0.005) and anterior (3204.9 vs. 4396.0 N, p = 0.000) approaches. Adding a total hip arthroplasty acetabular component also substantially reduced interfragmentary sliding for posterior (3.08 vs. 0.50 mm, p = 0.002) and anterior (2.17 vs. 0.29 mm, p = 0.024) approaches. Consequently, the anterior approach with a total hip arthroplasty may provide the best biomechanical stability for elderly patients, since this fixation group had the highest mechanical failure load and least interfragmentary sliding, while providing equivalent stiffness, clinical failure load, and gapping compared to other surgical options.


2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


2012 ◽  
Vol 27 (2) ◽  
pp. 305-309 ◽  
Author(s):  
David J. Jacofsky ◽  
John D. McCamley ◽  
Andrew M. Jaczynski ◽  
M. Wade Shrader ◽  
Marc C. Jacofsky

Sign in / Sign up

Export Citation Format

Share Document