This study investigates the clinical and radiological results of a tapered femoral stem (Corail®) and uncemented threaded acetabular cups (Tropic®) and in addition an analysis of the complications and retrieved implants was conducted. Between January 1990 and September 1998, 301 total hips arthroplasties in 268 patients were implanted. 78 patients (87 hips) had died and 9 patients (12 hips) had been lost to follow-up, leaving at the time of the latest follow-up 180 patients (202 hips). The mean age at surgery was 56,1 (27-75) years. Of the 154 unrevised hips, the median Harris and Merle d´Aubigne and Postel hip scores were 83,3 points and 15,3 points respectively at the latest follow-up. The median follow-up time was 16.9 years (10,4-25). No femoral component was revised for aseptic loosening ; osteolysis was observed in the 9,5% of the implants (13 stems). 48 hips (23%) were revised and 27 cups (56,2%) needed revision surgery because of massive polyethylene wear. Pelvic osteolysis was found out in 80 cups (58,8%). 87 hips (63,9%) showed signs of a progressive wear of the liner, more than 2mm in 48 hips. Kaplan-Meier survivorship analysis at 15 years follow-up was 81.2% with revision for any reason (85.8% for mechanical or radiographic loosening). High rates of polyethylene wear and the high prevalence of pelvic osteolysis are serious matters in these types of implants with high rates of revision at 15 years follow-up so we decided to abandon the concept of a threaded cup design in favor of a press-fit acetabular cup.


Author(s):  
Matthew A. Siegel ◽  
Michael J. Patetta ◽  
Jason Y. Chen ◽  
Diego M. Barragan Echenique ◽  
Mark H. Gonzalez

Author(s):  
Shahriar Sefati ◽  
Rachel Hegeman ◽  
Farshid Alambeigi ◽  
Iulian Iordachita ◽  
Peter Kazanzides ◽  
...  

2013 ◽  
Vol 28 (10) ◽  
pp. 1851-1855 ◽  
Author(s):  
Dong Hun Suh ◽  
Seung Beom Han ◽  
Ho Hyun Yun ◽  
Sung Kwang Chun ◽  
Won Yong Shon

2009 ◽  
Vol 1 (1) ◽  
pp. 16 ◽  
Author(s):  
Olof Sköldenberg ◽  
Mats Salemyr ◽  
Olle Muren ◽  
Åke Johansson ◽  
Torbjörn Ahl ◽  
...  

The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc and 166 Ringloc) on 281 patients in the study. Revisions of prosthesis components were recorded and pelvic osteolytic lesions were assessed using radiographs and computed tomography. The linear head penetration rate was measured using the Martell method. The 10-year survival rate of the liner with revision due to liner wear and/or osteolysis as endpoint was 88% for the Hexloc liner and 98% for the Ringloc liner. The 15-year survival rate of the Hexloc liner was 67%. Pelvic osteolysis was found in 27% of the Hexloc and 19% of the Ringloc hips. After 15 years, 53% of the Hexloc hips had developed an osteolytic lesion. The linear head penetration rate was 0.16 mm/year for the Hexloc liner and 0.12 mm/year for the Ringloc liner. This paper is the first to describe the rapidly deteriorating survival up to 15 years with the old generation gamma-in-air sterilized polyethylene used in Hexloc liners. The newer Ringloc liner with the ArCom™ polyethylene has superior clinical results but a linear wear rate and frequency of osteolytic lesions that is higher than expected.


2009 ◽  
Vol 24 (5) ◽  
pp. 743-750 ◽  
Author(s):  
Won Yong Shon ◽  
Siddhartha Gupta ◽  
Sandeep Biswal ◽  
Sang Hwan Han ◽  
Suk Joo Hong ◽  
...  

2009 ◽  
Vol 24 (2) ◽  
pp. 233-239 ◽  
Author(s):  
Hiroshi Egawa ◽  
Henry Ho ◽  
Robert H. Hopper ◽  
C. Anderson Engh ◽  
Charles A. Engh

Sign in / Sign up

Export Citation Format

Share Document