Bone plate fixation of distal radius and ulna fractures in small- and miniature-breed dogs

1999 ◽  
Vol 35 (3) ◽  
pp. 243-250 ◽  
Author(s):  
LJ Larsen ◽  
JK Roush ◽  
RM McLaughlin

Bone plate fixation was reviewed in 29 distal radial fractures of small- and miniature-breed dogs. Twenty-two fractures in 18 dogs were available for follow-up. Number of complications and return to function were evaluated. Complications occurred in 54% of the fractures. Catastrophic complications occurred in 18% of fracture repairs with follow-up, while minor complications occurred in 36%. Sixteen (89%) of 18 dogs had a successful return to function. Bone plate fixation is a successful repair method for distal radius and ulna fractures in small-breed dogs, compared to previously reported methods.

2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


Hand ◽  
2017 ◽  
Vol 13 (5) ◽  
pp. 563-571
Author(s):  
Jack Abboudi ◽  
Scott M. Sandilands ◽  
C. Edward Hoffler ◽  
William Kirkpatrick ◽  
William Emper

Background: Distal ulna fractures at the ulnar neck can be seen in association with distal radius fractures, and multiple techniques have been described to address the ulnar neck component of these injuries. We have found that treatment of ulnar neck fractures can be challenging in terms of anatomy and fracture fixation. We present a new percutaneous fixation technique for ulnar neck fractures commonly seen with distal radius fractures. Technique: Fixation of the ulnar neck fracture is performed after fixation of the distal radius fracture. Our technique uses anterograde intramedullary fixation to stabilize the fracture with a 1.6-mm (0.062 inch) Kirschner wire or a commercially available metacarpal fixation intramedullary nail. The fixation is introduced into the intramedullary space of the ulnar shaft 4 to 6 cm proximal to the fracture at a separate surgical site along the subcutaneous border of the ulna. The fixation is also supported with a sugar-tong splint for the first few weeks after surgery and requires removal of the ulnar implant approximately 10 weeks after implantation. Conclusion: Our technique utilizes a percutaneous approach with minimal fracture exposure. It provides a relatively simple and reproducible method to address ulnar neck fractures commonly seen in association with distal radial fractures.


2020 ◽  
Vol 09 (03) ◽  
pp. 219-224 ◽  
Author(s):  
Kamil Yamak ◽  
Hüseyin Gökhan Karahan ◽  
Berrak Karatan ◽  
Cemil Kayalı ◽  
Taşkın Altay

Abstract Background The aim of this study is to evaluate the frequency of flexor pollicis longus (FPL) tendon rupture and factors leading to this rupture during the follow-up of patients who underwent volar plate fixation because of distal radius fracture. Patients and Methods A total of 109 distal radius fractures of 102 patients treated with volar plate fixation and periodically followed up for at least 1 year between January 2013 and May 2018 were evaluated. Fractures were categorized according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA) Fracture-Dislocation Classification and Soong's grading was used for classifying volar plate position. All patients operated were inquired retrospectively in terms of flexor tendon rupture. Results Gender distribution revealed 45 females and 57 males. Mean age was 47.9 (range: 17–88) years. Mean period of follow-up was 27 months. Distribution of fractures in accordance with the AO/OTA distal radius classification was 6, 8, 7, 12, 24, 33, 11, and 8 patients with types A2, A3, B1, B2, B3, C1, C2, and C3, respectively. When volar plate positions were analyzed with Soong's classification, it revealed that 79 (72.4%), 23 (21.1%), and 7 (6.5%) plates were grade 0, 1, and 2, respectively. In total, evaluating the three patients with FPL rupture, it revealed that the volar plate was positioned distally during fixation because the fracture line had advanced to the distal of the watershed line, the distal portion of the plate had lost complete connection with the bone, and at this portion, it was observed that the pronator quadratus muscle was not covering the plate entirely (Soong's classification grade 2). Patients did not have additional flexor tendon injury. Conclusion FPL tendon rupture is a rare but serious complication of volar plate fixation performed for distal radius fractures. We believe that appropriate choice of implant and careful surgical technique, along with the close follow-up of patients, with Soong's classification grade-2 volar positions would help in preventing this complication. Level of Evidence This is a Level 3a, differential diagnosis/symptom prevalence study.


2020 ◽  
Vol 3 (1) ◽  

Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced extra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated with manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated to restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there is still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal end radius treated by open reduction and internal fixation using locking compression plating (LCP). Methods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital treated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and December 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by Gartland and Werley’s combined subjective and objective criteria. Results: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and studied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23 good results, and 07 fair results during latest follow up. Conclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the distal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the shape and function of the wrist.


Hand ◽  
2018 ◽  
Vol 14 (4) ◽  
pp. 540-546
Author(s):  
Jorge G. Boretto ◽  
Ezequiel E. Zaidenberg ◽  
Gerardo L. Gallucci ◽  
Alejandro Sarme ◽  
Pablo De Carli

Background: Acute management of fractures of the distal ulna that are associated with fractures of the distal radius remains difficult, particularly in the elderly. Methods: In this study, we investigated whether internal fixation of the distal ulna is associated with a higher rate of complications than resection of the distal ulna in patients older than 70 years. Twenty-four consecutive patients were included in this study, 12 of whom had undergone open reduction and internal fixation (ORIF) of the distal ulna, and 12 who had undergone distal ulna resection. Patients were retrospectively assessed for range of motion, grip strength, pain, and radiographic appearance. The functional outcome was evaluated by the Mayo Wrist Score. Complications were classified according to the Classification of Surgical Complications. Results: There were no differences in patient demographics between the 2 groups, except patient age. Clinical evaluation showed no difference at follow-up; however, there were significantly more complications associated with ORIF compared with resection. Conclusions: The results from our study show that women older than 70 years with fracture of the distal radius and distal ulna have a higher rate of complications if ORIF of the distal ulna is performed. Patients should be warned, by surgeons, of this in cases where ORIF of the distal ulna is suggested.


2015 ◽  
Vol 28 (02) ◽  
pp. 131-139 ◽  
Author(s):  
S. Cooley ◽  
J. J. Warnock ◽  
S. Nemanic ◽  
S. M. Stieger-Vanegas ◽  
W. I. Baltzer

SummaryObjectives: Evaluation of the short-term outcome, duration of bone healing, and complications following bone plate fixation in dogs weighing [uni2264]6 kg, with and without the use of a free autogenous greater omental graft (OG).Materials and methods: A retrospective clinical study reviewed the medical records of 25 dogs of body weight <6 kg with mid to distal diaphyseal fractures of the radius and ulna (29 fractures) treated with open reduction bone plate fixation. Thirteen out of 29 fractures were implanted with an additional 2–3 cm3 OG lateral, cranial, and medial to the fracture site, adjacent to the bone plate.Results: Median time to radiographic healing in OG fractures (n = 11) was 70 days (range 28–98) compared to 106 days (range: 56–144) in non-OG grafted fractures (n = 14). The OG dogs had no major complications; minor complications included oedema, erythema, and mild osteopenia. Six of the eight non-OG dogs for which follow-up could be obtained developed osteopenia necessitating implant removal, four of which re-fractured the radius one to five months after implant removal, with one dog re-fracturing the limb a second time and resulting in amputation. Telephone follow-up of owners of OG dogs (n = 11) three to 15 months (median 10) post-surgery did not identify any signs of lameness or other complications. Owners of the non-OG dogs (n = 8) reported that there were not any signs of lameness six to 48 months (median 36) post-surgery.Clinical relevance: Free autogenous omen-tal grafting of diaphyseal fractures of the radius and ulna was associated with radial and ulnar healing with minimal complications in dogs weighing less than 6 kg.


2020 ◽  
Author(s):  
Zhaofeng Jia ◽  
Shijin Wang ◽  
Wei Jiang ◽  
Chuangli Li ◽  
Jiandong Lin ◽  
...  

Abstract Background: Although distal radius fractures (DRFs) are clinically common, DRFs accompanied by dorsally displaced free fragments beyond the watershed line are much less so. At present, it is very difficult to fix and stabilize the displaced free fragments far away from the watershed line with a plate. Our aim was to investigate the clinical effect of DRFs with distally displaced dorsal free mass treated with distal volaris radius (DVR) combined with turning of the radius via the distal palmar approach. Methods: From 2015 to 2019, 25 patients with distal radius fractures associated with dorsally displaced free fragments beyond the watershed line were selected and treated with distal volaris radius (DVR) combined with turning of the radius via the distal palmar approach. This study involved 14 males and 11 females, with an average age of 34.5 years (ranging from 21 to 50 years). The mean follow-up period was 16.5 months (ranging from 12 to 22 months). The dorsal displacement of the free fragments was analyzed by X-ray and three-dimensional computed tomography, allowing characterization of postoperative recovery effects by radial height, volar tilt and radial inclination. For the follow-up, we evaluated effects of the surgery by analyzing range of motion (ROM); Modified Mayo Wrist Score (MMWS); and Disabilities of Arm, Shoulder and Hand (DASH) score. Postoperative wound recovery and complications were also monitored to evaluate the clinical therapeutic effects of the surgical procedures. Results: X-ray showed that all patients showed reduced fractures, well-healed wounds and recovered function with no obvious complications. Based on the follow-up, patients had a mean radial height of 10.5mm (ranging from 8.1 to 12.6 mm), mean MMWS of 78.8° (ranging from 61 to 90°), mean DASH score of 16.25 (ranging from 11 to 21), mean ROM for volar flexion of 76.5° (ranging from 62 to 81°), mean ROM for dorsiflexion of 77.1° (ranging from 59 to 83) and mean VAS score of 1.4 (ranging from 1 to 3). Conclusion: Treatment of distal radius fractures with accompanying dorsally displaced free fragments beyond the watershed line with turning of the radius and the DVR plate system via the distal palmar approach is effective and has no obvious complications.


Sign in / Sign up

Export Citation Format

Share Document