A NOVEL STABILITY INDICATING RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN BULK AND PHARMACEUTICAL FORMULATIONS

INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (08) ◽  
pp. 54-61
Author(s):  
B. Venkateswara Rao ◽  
◽  
S. Vidyadhara ◽  
V. Basaveswara Rao

The prime aim of the present investigation was to develop and validate a novel, precise, accurate, specific, rapid and economical stability- indicating isocratic reverse phase liquid chromatography method for the quantitative simultaneous estimation of valsartan and hydrochlorothiazide in bulk and marketed formulations. Estimation of drugs in this combination was achieved with a C18 column [Kromasil 100-5 C18 column, P134 250 × 4.6 mm] kept at ambient temperature, isocratic mode using mobile phase of composition acetonitrile and phosphate buffer (40:60 V/V, pH 4). The flow rate was 0.8 ml/min and the effluents were monitored at 235 nm, using variable wavelength UV detector. The retention time of valsartan and hydrochlorothiazide were 2.65 min and 3.97 min, respectively. Validation of the method was done according to the ICH guidelines for different analytical parameters. The method was found to be linear over a range of 50-250 μg/mL for valsartan and hydrochlorothiazide. The established method was as reproducible with a %RSD value of less than 2 and having robustness and accuracy within the specified limits. Assay of marketed formulation was determined and was 99.04% and 99.8% respectively. The stressed samples were analyzed. The proposed method was found to be specific and stability indicating as no interfering peaks of degradation compounds and excipients were noticed. The proposed method can be successfully employed in the estimation of commercial formulations.

INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (09) ◽  
pp. 67-73
Author(s):  
B. Venkateswara Rao ◽  
◽  
S. Vidyadhara ◽  
A. Ramu ◽  
N. Sai Prudhvi ◽  
...  

A simple, precise, accurate, reproducible and economical stability- indicating reverse phase liquid chromatography method was developed and validated for the quantitative simultaneous estimation of nebivolol and indapamide in bulk and marketed formulations. Estimation of drugs in this combination was done with a C18 column [Kromasil column. 250mm × 4.5 mm] using mobile phase of composition acetonitrile and phosphate buffer (60:40 V/V, pH 3). The flow rate was 0.8 ml/min and the effluents were monitored at 226nm. The retention time of nebivolol and indapamide were 2.9 min and 4.2 min, respectively. The method was found to be linear over a range of 10-50 μg/mL for nebivolol and 2-10 μg/mL for indapamide. The established method proved as reproducible one with a % RSD value of less than 2 and having the robustness and accuracy within the specified limits. Assay of marketed formulation was determined and found to be 99.08% and 99.87% for nebivolol and indapamide, respectively. The stressed samples were analyzed and this proposed method was found to be specific and stability indicating as no interfering peaks of degradation compounds and excipients were noticed. The method was validated according to the guidelines of International Conference on Harmonization (ICH) and was successfully employed in the estimation of commercial formulations. This liquid chromatographic method can be applied for the qualitative and quantitative determination of selected drugs by the modern chemist.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Sadana Gangishetty ◽  
Surajpal Verma

The present work describes a simple, rapid, and reproducible reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of clarithromycin (CLA) and paracetamol (PCM). C18 column (Kromasil ODS, 5 µm, 250 × 4.6 mm) and a mobile phase containing phosphate buffer (0.05 M) along with 1-octane sulphonic acid sodium salt monohydrate (0.005 M) adjusted to pH 3.2: acetonitrile (50 : 50 v/v) mixture was used for the separation and quantification. The flow rate was 1.0 mL/min and the eluents were detected by UV detector at 205 nm. The retention times were found to be 2.21 and 3.73 mins, respectively. The developed method was validated according to ICH guidelines Q2 (R1) and found to be linear within the range of 75–175 µg/mL for both drugs. The developed method was applied successfully for assay of clarithromycin and paracetamol in their combined in-house developed dosage forms and in vitro dissolution studies.


Author(s):  
T. Vimalakkannan ◽  
P. Shaik Parveen ◽  
Salomi ◽  
K. Ravindra Reddy

A simple, rapid, precise and accurate method is developed for the quantitative simultaneous determination of ceftriaxone and tazobactum in bulk and pharmaceutical formulations. Separation of ceftriaxone and tazobactum was successfully achieved by using Inertsil C18 ODS column 250X4.6mm, 5µm in an isocratic mode using water and acetonitrile (80:20) at a flow rate of 1.0 ml/min and was monitored at 254 nm with a retention time of 3.049 minutes and 4.317 minutes for ceftriaxone and tazobactum respectively. The method was validated and the response was found to be linear in the drug concentration range of 20µg/ml to 80 µg/ml for ceftriaxone and 5 µg/ml to 35 µg/ml for tazobactum. The values of the correlation coefficient were found to be 0.999 for ceftriaxone and 0.999 for tazobactum respectively. The LOD and LOQ for ceftriaxone were found to be 0.021 and 0.064 respectively. The LOD and LOQ for tazobactum were found to be 0.030 and 0.091 respectively. The percentage recovery for ceftriaxone and tazobactum were found to be 98-102% respectively which indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample. The method was extensively validated according to ICH guidelines for Linearity, Accuracy, Precision, Specificity and Robustness.  Stability of the drugs was determined by using acid/base, thermal, oxidative stress testing.


Sign in / Sign up

Export Citation Format

Share Document