STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF CEFTRIAXONE SODIUM AND SALBUTAMOL

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (09) ◽  
pp. 65-69
Author(s):  
Atul Sherje ◽  
◽  
Subhash Dhende ◽  
Mayur Yergiri

An isocratic liquid chromatographic method with UV detection at 230 nm is described for simultaneous determination of ceftriaxone sodium and salbutamol in bulk. Chromatographic separation of the two drugs was achieved on an Inertsil ODS© C18 (250 × 4.6 mm, 5 μ) using a mobile phase consisting of 50 mM potassium dihydrogen orthophosphate and methanol (77:23 %V/V) adjusted to pH 7.0 with triethylamine at a fl ow rate of 1.0mL min-1. The optimum separation was achieved in less than 10 minutes. The developed liquid chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. The method was validated as per ICH guidelines.

2020 ◽  
Vol 16 (8) ◽  
pp. 1037-1051
Author(s):  
Ehab Farouk Elkady ◽  
Marwa Ahmed Fouad ◽  
Abdulgabar A. Ezzy Faquih

Background: Atenolol is a selective beta 1 blocker that can be used alone or in combination with hydrochlorothiazide or with chlorthalidone for the treatment of hypertension and prevention from a heart attack. Objective: The main target of this work was to improve modern, easy, accurate and selective liquid chromatographic method (RP-HPLC) for the determination of these drugs in the presence of their degradation products. These methods can be used as analytical gadgets in quality control laboratories for a routine examination. Methods: In this method, the separation was accomplished through an Inertsil® ODS-3V C18 column (250 mm x 4.6 mm, 5 μm), the mobile phase used was 25 mM aqueous potassium dihydrogen orthophosphate solution adjusted to pH 6.8 by using 0.1M sodium hydroxide and acetonitrile (77 : 23, v/v), the flow rate used was 1 ml/min and detection was achieved at 235 nm using UV. Results: All peaks were sharp and well separated, the retention times were atenolol degradation (ATN Deg.) 2.311 min, atenolol (ATN) 2.580 min, hydrochlorothiazide degradation (HCT Deg.) 5.890 min, hydrochlorothiazide (HCT) 7.016 min, chlorthalidone degradation CTD Deg 8.018 min and chlorthalidone (CTD) 14.972 min. Linearity was obtained and the range of concentrations was 20- 160 μg/ml for atenolol, 10-80 μg/ml for hydrochlorothiazide and 10-80 μg/ml for chlorthalidone. According to ICH guidelines, method validation was accomplished, these methods include linearity, accuracy, selectivity, precision and robustness. Conclusion: The optimized method demonstrated to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.


2019 ◽  
Vol 15 (6) ◽  
pp. 635-641
Author(s):  
Nadia M. Mostafa ◽  
Ghada M. Elsayed ◽  
Nagiba Y. Hassan ◽  
Dina A. El Mously

Background:The concept of green analytical chemistry prevails due to the growing environmental pollution.Objective:Our attempts are to develop simple and eco-friendly method which is non-harmful to the environment by producing minimal waste. In this context, a green liquid chromatographic method was applied for the simultaneous determination of chlorpheniramine maleate, pseudoephedrine hydrochloride and propyphenazone in their combined dosage form.Methods:Separation was carried out using X select HSS RP C18 analytical column (250 × 4.6 mm, 5μm) using methanol - 0.02 M phosphate buffer pH 3 - triethylamine (60:40: 0.1, by volume) as a mobile phase. The separated peaks were detected at 215 nm at a flow rate 1.0 mL/min.Results:Quantification was done over the concentration ranges of 1-25 µg/mL for chlorpheniramine maleate, 5-35 µg/mL for pseudoephedrine hydrochloride and 10-120 µg/mL for propyphenazone. The suggested method was validated with regard to linearity, accuracy and precision according to the International Conference on Harmonization guidelines with good results.Conclusion:It could be used as a safer alternative for routine analysis of the mentioned drugs in quality control laboratories.


2009 ◽  
Vol 92 (2) ◽  
pp. 404-409 ◽  
Author(s):  
Abdalla A Elshanawane ◽  
Samia M Mostafa ◽  
Mohamed S Elgawish

Abstract A high-performance liquid chromatographic method was developed for the simultaneous determination of 2 ternary mixtures containing amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone used in hypertension therapy. The use of cyanopropyl column results in satisfactory separation of both mixtures. The mobile phase consisted of 10 mM KH2PO4 buffer (pH 4.5) and methanol in a ratio of (75 25 v/v), at a flow rate of 1 mL/min. UV detector was operated at 275 nm. Calibration graphs were linear in the concentration ranges of 210, 20200, 10100, and 550 g/mL for amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone, respectively. Intraday and interday precision values (relative standard deviation) were <1.13 for mixture I (amiloride hydrochloride, atenolol, chlorthalidone), and <0.93 for mixture II (amiloride hydrochloride, atenolol, hydrochlorothiazide). The method was successfully applied for the determination of the 2 combinations in laboratory-prepared mixtures and commercial pharmaceutical formulation with high accuracy and precision. Statistical comparison of the results with those of the published methods showed excellent agreement and indicates no significant difference between them.


2020 ◽  
Vol 1626 ◽  
pp. 461388
Author(s):  
Gergő Tóth ◽  
Erzsébet Fogarasi ◽  
Ágnes Bartalis-Fábián ◽  
Mohammadhassan Foroughbakhshfasaei ◽  
Imre Boldizsár ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document