scholarly journals Energy and exergy analysis study of heat exchanger in a refrigeration system with different lengths of capillary tube

2020 ◽  
Vol 23 (4) ◽  
pp. 260-266
Author(s):  
Thamer SALEM ◽  
Saad FARHAN ◽  
Israa FARHAN
2017 ◽  
Vol 6 (4) ◽  
pp. 91 ◽  
Author(s):  
Luke Ajuka ◽  
Moradeyo Odunfa ◽  
Olayinka Ohunakin ◽  
Miracle Oyewola

The experimental study investigated the energy and exergy performance of a domestic refrigerator using eco-friendly hydrocarbon refrigerants R600a and LPG (R290/R600a: 50%/50%) at 0, 0.05, 0.15 and 0.3wt % concentrations of 15nm particle size of TiO2 nano-lubricant, and R134a. The effects of evaporator temperature on power consumption, coefficients of performance, exergetic efficiency and efficiency defects in the compressor, condenser, capillary tube and evaporator of the system were examined. The results showed that LPG + TiO2 (0.15wt %) and R600a + TiO2 (0. 15wt %) had the best of performances with an average of 27.6% and 14.3% higher coefficient of Performance, 34.6% and 35.15% lower power consumption, 13.8% and 17.53% higher exergetic efficiency, a total exergetic defect of 45.8% and 64.7% lower compared to R134a. The exergetic defects in the evaporator, compressor, condenser, and capillary tube were 38.27% and 35.5%, 49.19% and 55.56%, 29.7% and 33.7%, 39.1% and 73.8% lower in the system when compared to R134a respectively. Generally, the refrigerants with nano-lubricant mixture gave better results with an appreciable reduction in the exergy defect in the compressor than the pure refrigerants, and LPG + TiO2 (0. 15wt %) gave the best result in the refrigeration system based on energy and exergy analysis.


Author(s):  
Hendri ◽  
Roswati Nurhasanah ◽  
Prayudi ◽  
Suhengki

Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.


Sign in / Sign up

Export Citation Format

Share Document