scholarly journals Takotsubo syndrome after pericardial tamponade following cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation and complicated by right coronary artery thrombosis

2017 ◽  
Vol 24 (2) ◽  
pp. 216-216
Author(s):  
Jarosław Hiczkiewicz ◽  
Edward Koźluk ◽  
Katarzyna Łojewska ◽  
Jan Budzianowski ◽  
Rafał Zimoląg ◽  
...  
2017 ◽  
Vol 81 (5) ◽  
pp. 668-674 ◽  
Author(s):  
Ryobun Yasuoka ◽  
Takashi Kurita ◽  
Yasuhito Kotake ◽  
Naotaka Hashiguchi ◽  
Koichiro Motoki ◽  
...  

2021 ◽  
Vol 29 (3) ◽  
pp. 395-398
Author(s):  
Hatice Dilek Özcanoğlu ◽  
İsa Özyılmaz

Perinatal myocardial infarction caused by aortic root and coronary artery thrombosis in neonatal period is extremely rare and has a gloomy prognosis that may cause devastating complications. A 3-h newborn baby who had acute myocardial infarction findings on postnatal electrocardiography had a thrombus in the aortic root with hyperechogenic right coronary artery region, and impaired right ventricular functions on echocardiography. The patient was urgently operated and thrombus was successfully removed from the aortic root and the right coronary artery. In conclusion, for large thrombi posing a risk for embolization in the aortic root, an urgent surgical thrombectomy procedure should be performed.


QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p < 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.


2009 ◽  
Vol 17 (3) ◽  
pp. 115-116 ◽  
Author(s):  
R. J. Hassink ◽  
H. E. Haerkens-Arends ◽  
M. C. G. Daniels

2013 ◽  
Vol 61 (16) ◽  
pp. 1713-1723 ◽  
Author(s):  
Douglas L. Packer ◽  
Robert C. Kowal ◽  
Kevin R. Wheelan ◽  
James M. Irwin ◽  
Jean Champagne ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document