scholarly journals Detection of Inferior Vena Cava Thrombosis Extending into the Right Atrium Using Point-of-care Ultrasound

2019 ◽  
Vol 3 (1) ◽  
pp. 67-68 ◽  
Author(s):  
Justin Yanuck ◽  
Ghadi Ghanem ◽  
Shadi Lahham
Author(s):  
Yu-An Chen ◽  
Yueh Li ◽  
Jen-chieh Lee ◽  
JENG-WEI CHEN

Intimal sarcomas simultaneously involving the right atrium and the inferior vena cava are rare. We report an advanced cardiac intimal sarcoma in the right atrium of a 19-year-old man that was complicated by tumor-related inferior vena cava thrombosis. We initially performed partial tumor resection and vena cava thrombectomy to resolve the circulatory obstruction, because complete resection was difficult due to the invading malignancy and an unclear margin. The patient received adjuvant chemo- and radiotherapy along with anticoagulant therapy. After 3 months, the border of the residual sarcoma was clear, and the patient underwent a secondary complete sarcoma excision (including that of the right atrium) and a suprahepatic vena cava reconstruction. At the 2-year follow-up, there was no tumor recurrence. We conclude that aggressive treatment and a staged complete resection can lead to improved outcomes for advanced cardiac intimal sarcoma with poor prognosis.


2014 ◽  
Vol 30 (5) ◽  
pp. 569-571 ◽  
Author(s):  
Meggan L. Goodpasture ◽  
Kristen A. Zeller ◽  
John K. Petty

2021 ◽  
pp. 026835552092598
Author(s):  
Jacob J Bundy ◽  
Jeffrey Forris Beecham Chick ◽  
Ravi N Srinivasa ◽  
Kyle J Cooper ◽  
Joseph J Gemmete ◽  
...  

Objective The Simon Nitinol filter is a bi-level filtration device designed for permanent implantation that is no longer commercially available, but may result in similar complications to current commercially available long term indwelling temporary or permanent filters. Complications related to indwelling inferior vena cava filters include inferior vena cava thrombosis, inferior vena cava penetration, filter migration, and filter fracture. There is a paucity of reports describing the technical aspects related to retrieval of Simon Nitinol filters. Materials and methods This study consisted of five patients with Simon Nitinol filters and describes the indication for retrieval, the retrieval techniques used to remove the filters, technical success, complications, and clinical course. Results The indications for retrieval included: abdominal pain ( n = 2; 40%), iliocaval thrombosis ( n = 1; 20%), identification of an intracardiac filter fragment ( n = 1; 20%), and recurrent venous thromboembolic events ( n = 1; 20%). Retrieval techniques included: biopsy forceps ( n = 3; 60%), excimer laser extraction sheaths ( n = 3; 60%), hangman modified loop snares ( n = 3; 60%), rigid endobronchial forceps ( n = 2; 40%), and balloon deflection ( n = 2; 40%). All filters were successfully retrieved. One patient developed a post-procedural intramuscular hematoma near the site of right internal jugular sheath placement. Conclusions Simon Nitinol filters may be retrieved safely and effectively using advanced inferior vena cava filter retrieval techniques.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Christian Steinberg ◽  
Suzanne Boudreau ◽  
Felix Leveille ◽  
Marc Lamothe ◽  
Patrick Chagnon ◽  
...  

Hepatocellular carcinoma usually metastasizes to regional lymph nodes, lung, and bones but can rarely invade the inferior vena cava with intravascular extension to the right atrium. We present the case of a 75-year-old man who was admitted for generalized oedema and was found to have advanced HCC with invasion of the inferior vena cava and endovascular extension to the right atrium. In contrast to the great majority of hepatocellular carcinoma, which usually develops on the basis of liver cirrhosis due to identifiable risk factors, none of those factors were present in our patient.


Sign in / Sign up

Export Citation Format

Share Document