scholarly journals Experimental validation of a cardiac simulator for in vitro evaluation of prosthetic heart valves

Author(s):  
Ovandir Bazan ◽  
Jayme Pinto Ortiz
1980 ◽  
Vol 102 (1) ◽  
pp. 34-41 ◽  
Author(s):  
G. E. Chetta ◽  
J. R. Lloyd

Although prosthetic heart valves have been in existence for many years, the need for new improved designs and in-vitro evaluation techniques are apparent. This paper presents details on the design considerations, fabrication techniques and heart valve evaluation equipment. A valve performance index is discussed in light of various valve and mock circulatory test section designs. The need for national and indeed international valve evaluation techniques is made apparent.


1973 ◽  
Vol 29 (03) ◽  
pp. 694-700 ◽  
Author(s):  
Paul L. Rifkin ◽  
Marjorie B. Zucker

SummaryDipyridamole (Persantin) is reported to prolong platelet survival and inhibit embolism in patients with prosthetic heart valves, but its mechanism of action is unknown. Fifty jxM dipyridamole failed to reduce the high percentage of platelets retained when heparinized human blood was passed through a glass bead column, but prolonged the inhibition of retention caused by disturbing blood in vitro. Possibly the prostheses act like disturbance. Although RA 233 was as effective as dipyridamole in inhibiting the return of retention, it was less effective in preventing the uptake of adenosine into erythrocytes, and more active in inhibiting ADP-induced aggregation and release. Thus there is no simple relation between these drug effects.


Author(s):  
Raimond Grimberg ◽  
Adriana Savin ◽  
Shiu C. Chan ◽  
Rozina Steigmann ◽  
Lalita Udpa ◽  
...  

Prosthetic heart valves of the Bjork-Shiley Convexo-Concave (BSCC) type have long been used extensively in implants; however, there have been reports of cases where one component of the valves failed, leading to the demise of the patient. This paper presents a new method for noninvasive electromagnetic evaluation for this type of valve, using an eddy current transducer with orthogonal coils. In vitro experiments have shown that discontinuities of outlet strut with depths equal or larger than 0.4mm can be detected with a probability of detection (POD) of 86.4%, and in the case of discontinuities with depth equal or larger than 0.6mm with POD of 97%.


Author(s):  
Martin Gottwik ◽  
S. Hartung ◽  
O. Epe ◽  
S. Langsdorf ◽  
J. Thormann ◽  
...  

1984 ◽  
Vol 106 (1) ◽  
pp. 83-88 ◽  
Author(s):  
T. Kitamura ◽  
T. Kijima ◽  
H. Akashi

This paper demonstrates a modeling technique of prosthetic heart valves. In the modeling, a pumping cycle is divided into four phases, in which the state of the valve and flow is different. The pressure-flow relation across the valve is formulated separately in each phase. This technique is developed to build a mathematical model used in the real time estimation of the hemodynamic state under artificial heart pumping. The model built by this technique is simple enough for saving the computational time in the real time estimation. The model is described by the first-order ordinary differential equation with 12 parameters. These parameters can be uniquely determined beforehand from in-vitro experimental data. It is shown that the model can adapt, with sufficient accuracy, to a change in the practical pumping condition and the viscosity of the fluid in their practical range, and is also demonstrated that the estimated backflow volume by model agrees closely with the actual one.