scholarly journals Early–Age Shrinkage of High-Performance Concrete Beam in Laboratory and Full-Scale

2019 ◽  
2009 ◽  
Vol 419-420 ◽  
pp. 1-4 ◽  
Author(s):  
Ying Wei Yun ◽  
Ii Young Jang ◽  
Seong Kyum Kim ◽  
Seung Min Park

High-performance concrete (HPC) as a promising construction material has been widely used in infrastructures and high-rise buildings etc. However, its pretty high autogenous shrinkage (AS) especially in its early age becomes one of the key problems endangering long-time durability of HPC structures. This paper carried out the early age AS research of large scaled HPC column specimens by embedded Fiber Bragg-Grating (FBG) strain sensor. Temperature compensation for FBG strain sensor by thermocouple was also attempted in this paper, and the results were reasonable and acceptable comparing with the result compensated by FBG temperature sensor. Reinforcement influence, size effect and temperature effect on HPC AS were also analyzed respectively in this paper.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6964
Author(s):  
Mohamed Abokifa ◽  
Mohamed A. Moustafa

Full-depth precast bridge decks are widely used to expedite bridge construction and enhance durability. These deck systems face the challenge that their durability and performance are usually dictated by the effectiveness of their field joints and closure joint materials. Hence, commercial ultra-high performance concrete (UHPC) products have gained popularity for use in such joints because of their superior mechanical properties. However, the proprietary and relatively expensive nature of the robust UHPC mixes may pose some limitations on their future implementation. For these reasons, many research agencies along with state departments of transportation sought their way to develop cheaper non-proprietary UHPC (NP-UHPC) mixes using locally supplied materials. The objective of this study is to demonstrate the full-scale application of the recently developed NP-UHPC mixes at the ABC-UTC (accelerated bridge construction university transportation center) in transverse field joints of precast bridge decks. This study included experimental testing of three full-scale precast bridge deck subassemblies with transverse NP-UHPC field joints under static vertical loading. The test parameters included NP-UHPC mixes with different steel fibers amount, different joint splice details, and joint widths. The results of this study were compared with the results of a similar proprietary UHPC reference specimen. The structural behavior of the test specimens was evaluated in terms of the load versus deflection, reinforcement and concrete strains, and full assessment of the field joint performance. The study showed that the proposed NP-UHPC mixes and field joint details can be efficiently used in the transverse deck field joints with comparable behavior to the proprietary UHPC joints. The study concluded that the proposed systems remained elastic under the target design service and ultimate loads. In addition, the study showed that the use of reinforcement loop splices enhanced the load distribution across the specimen’s cross-section.


2019 ◽  
Vol 271 ◽  
pp. 07008
Author(s):  
William Toledo ◽  
Leticia Davila ◽  
Ahmed Al-Basha ◽  
Craig Newtson ◽  
Brad Weldon

This paper investigates the shrinkage and thermal effects of an ultra-high performance concrete (UHPC) mixture proposed for use as an overlay material for concrete bridge decks. In this study, early-age and longer-term shrinkage tests were performed on the locally produced UHPC. Thermal and shrinkage effects in normal strength concrete slabs overlaid with UHPC were also observed. Early-age shrinkage testing showed that approximately 55% of the strain occurred in the plastic state and may not contribute to bond stresses since the elastic modulus of the UHPC should be small at such early ages. Thickness of the substrate and amount of reinforcing steel were important factors for shrinkage in the slabs. The thickest slab experienced greater shrinkage than thinner slabs. Comparing this slab to a thinner slab with the same reinforcement indicated that reinforcement ratio is more important than the area of steel.