scholarly journals Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur

Cureus ◽  
2021 ◽  
Author(s):  
Siddhartha Singh
Author(s):  
SPS Gill ◽  
Ankit Mittal ◽  
Manish Raj ◽  
Satosh Singh ◽  
Ajay Rajpoot ◽  
...  

Introduction: Despite recent evolution in the operating techniques and surgical implants, debate continues around the choice of implant for the management of intertrochanteric fractures of femur bone. There is a paucity of clinical data on the results with Proximal Femoral Nail Antirotation (PFNA). Aim: To evaluate the functional and radiological outcome of reduction and fixation of these fractures with PFNA. Materials and Methods: This prospective interventional study was conducted from december 2015 to november 2018. A total of 62 patients of more than 50 years of age with intertrochanteric fracture were managed with internal fixation using PFNA. All the pateints were evaluated with respect to the mean operative time, blood loss. Fluoroscopy exposure, time to union and development of any complication. The statistical analysis involved calculation of the mean and Standard Deviations (SD) of above parameters which was done using the Microsoft excel chart sheet. Functional evaluation was done using the Harris Hip Score (HHS). Results: A total of 62 patients with age ranging from 54 to 94 years (mean 78.2, SD 09.11) were evaluated. The mean duration of follow-up was 14.3 months. The average operative time, the mean blood loss and the average fluoroscopy time were 61.4 (range 45-90 minutes, SD 11.6) minutes, 103.9 (range 60-200 mL, SD 36.4) mL and 74.0 (range 41 to 98, SD 13.5) seconds respectively. About 100% union rate with the average time to union being 16.1 (SD 3.3) weeks and ranging from 12 weeks to 24 weeks was reported. Varus collapse and limb shortening >1 cm were observed in 3 patients. The average HHS at the end of study showed a mean value of 82.8 (SD 8.6) and ranged from 65 to 94 with 46 (74.2%) patients having excellent to good outcome. Conclusion: Owing to easy insertion, reduced operative time and blood loss, stable fixation, less complications and good functional and radiological outcome, PFNA can prove to be an implant of choice for the management of intertrochantric fractures of the femur.


2020 ◽  
Vol 12 (2) ◽  
pp. 543-551
Author(s):  
Qian Cheng, MD ◽  
Li Lin, BM ◽  
Xiao‐dong Zhu, MD ◽  
Gui‐zhu Li, MD ◽  
Xiao‐ming Gao, BM ◽  
...  

Author(s):  
OP Jamshad ◽  
Jacob Mathew ◽  
Raju Karuppal

Introduction: Intertrochanteric fractures are prevalent in the elderly, which leave patients with functional restrictions. Proximal Femoral Nail Antirotation-2 (PFNA) was developed to achieve better fixation strength, particularly in the presence of osteoporotic unstable intertrochanteric fractures. Aim: To evaluate the role and result of PFNA-2 in the treatment of unstable intertrochanteric fractures in geriatric patients. Materials and Methods: A prospective analytical study was conducted in 35 patients with unstable intertrochanteric fractures. They were followed-up clinically and radiologically for one year. The quality of fixation was assessed, by neck-shaft angle and Tip Apex Distance (TAD). A functional assessment was done with the Harris Hip Score (HHS). Results: The mean follow-up period was 13 months (range, 12-14). The mean age of patients was 65.6 years and the majority were female patients (62.85%). Functional results according to modified HHS were found to be excellent in 6 (17.1%) patients, good in 14 (40%) patients, fair in 12 (34.3%) patients and poor in 3 (8.6%) patients. The average HHS in this study was 81.6. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 16.0. Conclusion: PFNA-2 helps in achieving biological reduction and good stability which enables early mobilisation and prevention of excessive collapse. A good functional outcome could be achieved when the radiological parameters are restored, i.e., TAD <25 mm and neck-shaft angle difference <5° (compared to the opposite side).


Author(s):  
Jian Chen ◽  
Jian-xiong Ma ◽  
Ying Wang ◽  
Hao-hao Bai ◽  
Lei Sun ◽  
...  

Abstract Background More elderly patients are suffering from intertrochanteric fractures. However, the choice of internal fixation is still controversial, especially in the treatment of unstable intertrochanteric fracture; thus, previous implants continue to be improved, and new ones are being developed. The purpose of our study was to compare the biomechanical advantages between the zimmer natural nail (ZNN) and proximal femoral nail antirotation-II (PFNA-II) in the treatment of elderly reverse obliquity intertrochanteric fractures. Methods A three-dimensional finite element was applied for reverse obliquity intertrochanteric fracture models (AO31-A3.1) fixed with the ZNN or PFNA-II. The distribution, peak value and position of the von Mises stress and the displacement were the criteria for comparison between the two groups. Results The stresses of the internal fixation and femur in the ZNN model were smaller than those in the PFNA-II model, and the peak values of the two groups were 364.8 MPa and 171.8 MPa (ZNN) and 832.3 MPa and 1795.0 MPa (PFNA-II). The maximum amount of displacement of the two groups was similar, and their locations were the same, i.e., in the femoral head vertex (3.768 mm in the ZNN model and 3.713 mm in the PFNA-II model). Conclusions The displacement in the two models was similar, but the stresses in the implant and bone were reduced with the ZNN. Therefore, the ZNN implant may provide biomechanical advantages over PFNA-II in reverse obliquity intertrochanteric fractures, as shown through the finite element analysis. These findings from our study may provide a reference for the perioperative selection of internal fixations.


Sign in / Sign up

Export Citation Format

Share Document