scholarly journals DEVELOPMENT AND VALIDATION OF UV SPECTROPHOTOMETRIC ESTIMATION OF EBASTINE IN BULK AND TABLET DOSAGE FORM USING AREA UNDER CURVE METHOD

2013 ◽  
Vol 4 (6) ◽  
pp. 201-204 ◽  
Author(s):  
Manish Sudhakar Dahivadkar ◽  
Hemant Kumar Jain ◽  
Kishore Namdeorao Gujar
2016 ◽  
Vol 6 ◽  
Author(s):  
Rajeshri Dineshbhai Patel ◽  
Riddhi Hiteshbhai Shukla ◽  
Prakruti Rajeshbhai Buch

<strong>Ibuprofen is a nonsteroidal anti-inflammatory agent (NSAIA) with analgesic and antipyretic properties. Famotidine is a competitive histamine H2-receptor antagonist, is used to treat gastrointestinal disorders such as gastric or duodenal ulcer. The aim of the present research work was to develop accurate and rapid Area under Curve Method to determine Ibuprofen and Famotidine in combined dosage form. The Area under Curve method, wavelength range selected are 259-269 nm for Ibuprofen and 282-292 nm for Famotidine respectively. The developed method was obeyed the Beer’s law and was f</strong><strong>ound linearity range between 80-640 μg/ml for IBU and 2-22 μg/ml for Famotidine; while the correlation coefficient were 0.9985 for Ibuprofen and 0.9982 for Famotidine. Parameters such as linearity, accuracy, precision, LOD and LOQ values were used for validation of the methods as per ICH guidelines for both methods. Intra and inter-day precision %RSD values were less than 2%. This method is found suitable for day to day analysis of Ibuprofen and Famotidine in combined dosage form.</strong>


2021 ◽  
Vol 11 (2) ◽  
pp. 16-22
Author(s):  
Megha Mishra ◽  
Anand Mundada

A UV spectrophotometric method has been developed for the simultaneous determination of Artemether and Lumefantrine. The spectroscopic method for estimation of Artemether and Lumefantrine employed Area under curve method for analysis using Ethanol as solvent. Artemether has absorbance maxima 253.2 nm and Lumefantrine has absorbance maxima 235.2 nm and both these drugs obey Beer's law in concentration range of 4.24 -67.84 μg/ml for Artemether and 4.68 -28.08 μg/ml for Lumefantrine. The recovery studies ascertained the accuracy of the purposed method and the results were validated as per ICH guidelines. The results were found satisfactory and reproducible. The method was applied successfully for the estimation of Artemether and Lumefantrine in tablet dosage form without the interference of common excipients. Keywords: Artemether, Lumefantrine; Area under curve; Simultaneous; Estimation


2017 ◽  
Vol 29 (5) ◽  
pp. 1113-1118
Author(s):  
T.S.S. Jagan Mohan ◽  
Datla Peda Varma ◽  
Khagga Bhavyasri ◽  
Kancherla Prasad ◽  
Khagga Mukkanti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document