scholarly journals Performance Assessment of Drip System of Irrigation used for Cultivating Tomato in Premises of the Centre of Excellence Protected Cultivation, Raipur, Chhattisgarh, India

Author(s):  
Vijay Sahu ◽  
Jeet Raj ◽  
Sanket Kolambe ◽  
. Aman

A technical report was conducted for checking performance assessment of drip irrigation system which was used for cultivating tomato in premises of the Centre of Excellence Protected Cultivation, Raipur (Chhattisgarh). A uniformity coefficient was found for drip irrigation system which ranges from 73.2 % to 83.6%. The coefficient of variance varies between 0.0055 to 0.0068 for the measured discharges of four laterals laid in the field. It shows that there is the least variation between the obtained flow rates of different laterals under study. The application efficiency of four different lateral lines operating at a pressure of 1.25 kg/cm2 was calculated and it found to be more than 90.00 %, excluding lateral line (L2). Almost same amount of flow variation (8-9%) is found in lateral lines L1, L3 and L4, although Lateral line (L2) discharges 11.00 % more water among others. The maximum flow variation was found for the lateral line (L3) and the least flow variation was for the lateral line (L1). The distribution efficiency of all the laterals was found more than 97.45 %.

2019 ◽  
Vol 31 (2) ◽  
Author(s):  
Olorunwa Eric Omofunmi ◽  
Oluwaseun Ayodele Ilesanmi ◽  
Toluwalase Orisabinone

Experiment was carried out in the department of Agricultural and Bioresources Engineering, during the period of August to October, 2017. The hydraulic performance of a developed drip irrigation system was assessed. The experimental work was conducted on field with irrigated field area of 7 m x 3 m and lateral spacing was 0.35 m. Sixty (60) hospital drip sets (given sets) were used for the experiment as improved emitters. Volumetric method was used to determine application rate (PR) and emitters discharge. The emission uniformity, emitter flow variation, co-efficient of uniformity and co-efficient of variation were determined accordance with the equations described by the American Society of Agricultural Engineering (ASAE). Soil chemical properties were determined accordance with the American Public Health Association (APHA). The findings revealed that the soil in the area is classified as sand clay loam and normal soil. Results indicated that the mean and standard deviation of the emitters were 9.639 L/hr and 0.07 L/hr respectively. There were no emitters clogging. The emitter flow variation was 2.5 % and less than 10 % which was desirable range, while coefficient of variation was 0.07 and less than 0.11 which was marginal. The application rate was 17 mm hr-1 which was within the recommended range of 15 – 25 mm hr-1. The emission uniformity and coefficient of uniformity were 99.4% and 99.2% respectively, which shows that the system was well-designed. This finding indicated that hospital drip sets proved to the high quality. Therefore, it can be used as standard emitter.


10.5772/30320 ◽  
2011 ◽  
Author(s):  
Nigussie Haregeweyn ◽  
Abraha Gebrekiros ◽  
Atsushi Tsunkeawa ◽  
Mitsuru Tsubo ◽  
Derege Meshesha ◽  
...  

2012 ◽  
Vol 54 (4) ◽  
pp. 29-38
Author(s):  
Won-Ho Nam ◽  
Jin-Yong Choi ◽  
Soon-Kun Choi ◽  
Eun-Mi Hong ◽  
Sang-Ho Jeon ◽  
...  

In the agriculture field, the method of irrigation and its proper usage is more important and it is well known that a very economical and efficient method is drip irrigation. The continuous monitoring of the soil and weather condition has to be done by the farmer in favour of growth of crops in conventional drip irrigation system. In this proposed system, the soil and weather condition of the field are monitored by the moisture as well as temperature sensor. The values from the temperature and moisture sensors are sensed and the signal is sent to the Arduino IDE controller which is powered by solar energy and thus the present values are compared with predefined values. According to value of the temperature and moisture, the crops can be supplied with the required amount of water. In the liquid crystal display, the sensed values of the temperature and moisture will be displayed and the user can receive the data through the GSM module.


Author(s):  
Eddy Herman Sharu

Irrigation is the most important component in ensuring that crops can produce optimal yields. The use of drip irrigation can help farmers in providing water to crops in the amount required by the crop. Drip irrigation usually uses an uncompensated dripper and also a pressure compensated dripper. The use of an uncompensated dripper requires precise pressure to ensure a uniform flow for each dripper while the use of a pressure compensated dripper will also provide a uniform flow when operating pressure was used within the range specified by the dripper manufacturer. The purpose of this study is to evaluate the hydraulic performance of the drip irrigation system using low pressure compared to the minimum pressure recommended by dripper manufacturers. The pressure operation recommended by the manufacturer is 1.5-4 bars. This study uses pressures as low as 1 bar (low pressure), 2 bars, and 2.5 bars (recommended by manufacture) to operate this irrigation system. The volumetric approach was used to calculate each emitter's flow rate. Coefficient uniformity (CU), emission uniformity (EU), coefficient of variation (CV), and emitter flow variation (EFV) were the hydraulic parameters evaluated. The results show that CU, CV, and EU are in excellent classification, and the value for CU and the EU is more than 95 percent efficiency. The CV value is below 0.03 which is a very good classification. Meanwhile, emitter flow variation is 10% when operating at 2.5 bars and 2.0 bars and is considered the desirable classification. On the other hand, the emitter flow variation was reported at 6% for the 1 bar operating pressure and the classification was also recorded in the desirable classification. The results conclude that the use of low operating pressure compared to the minimum operating pressure proposed by the manufacturer can also operate in excellent condition according to the hydraulic parameters evaluated.


Irriga ◽  
2018 ◽  
Vol 1 (2) ◽  
pp. 14-18
Author(s):  
Taiane de Almeida Pereira ◽  
Alexandre Reuber Almeida da Silva ◽  
Marcos Makeison Moreira de Sousa ◽  
Cristian De França Santos ◽  
Daniel Lima dos Santos

PRESSÕES DE SERVIÇOS E SEUS EFEITOS NO DESEMPENHO DE UM SISTEMA DE IRRIGAÇÃO POR GOTEJAMENTO     TAIANE DE ALMEIDA PEREIRA1; ALEXANDRE REUBER ALMEIDA DA SILVA2; MARCOS MAKEISON MOREIRA DE SOUSA3; CRISTIAN DE FRANÇA SANTOS1 E DANIEL LIMA DOS SANTOS1   1Graduandos em Tecnologia em Irrigação e Drenagem, Instituto Federal de Educação Ciência e Tecnologia do Ceará – campus Iguatu, Rodovia Iguatu/Várzea Alegre, Km 05 – Vila Cajazeiras – Iguatu-CE. CEP: 63.503-790; taianeirrigacao@gmail; [email protected]; [email protected]; 2Professores do Curso de Tecnologia em Irrigação e Drenagem, Instituto Federal de Educação Ciência e Tecnologia do Ceará – campus Iguatu, Rodovia Iguatu/Várzea Alegre, Km 05 – Vila Cajazeiras – Iguatu-CE. CEP: 63.503-790, [email protected]; 3Mestrando em Engenharia Agrícola, Departamento de Engenharia Agrícola, Universidade Federal do Ceará – campus do Pici, Centro de Ciências Agrárias – CCA/UFC, Bloco 804, Fortaleza CE, CEP: 60.455-760; [email protected].     1 RESUMO   O presente trabalho teve como objetivo analisar a uniformidade de distribuição de em um sistema de irrigação localizada, do tipo gotejamento operando em condições de campo sob diferentes pressões de serviços, por meio da determinação dos Coeficiente de Uniformidade de Christiansen (CUC), do Coeficiente de Uniformidade de Distribuição (CUD) e do Coeficiente de Uniformidade Estatística (Us). Em campo, foram utilizadas 4 linhas laterais escolhidas ao acaso e com o auxílio de proveta e cronômetro, foram aferidos os volumes de água em 4 gotejadores de parede delgada, em três repetição em um tempo de 60 segundos, observando as 3 diferentes pressões de serviço (5,1; 10,2 e 15,3 mca). A média dos valores encontrados para o Coeficiente de Uniformidade de Christiansen (CUC), Coeficiente de Uniformidade de Distribuição (CUD) e o Coeficiente de Uniformidade Estatística (Us) são considerados pela literatura especializada como excelentes.  Todavia, na pressão de serviço de 5,1 mca, a uniformidade de distribuição de água tende a ser comprometida. Infere-se, portanto, que o sistema de irrigação está bem dimensionado evitando assim danos financeiros, independente das pressões de serviços nas quais o mesmo esteja operando.   Palavras-Chave: uniformidade, microirrigação, alturas manométricas.     PEREIRA, T. DE A.; SILVA, A. R. A. DA; SOUSA, M. M. M. DE; SANTOS, C. DE F.; SANTOS, D. L. DOS SERVICE PRESSURES AND THEIR EFFECTS ON THE PERFORMANCE OF A DRIP IRRIGATION SYSTEM     2 ABSTRACT   The objective of this work was to analyze the distribution uniformity of a drip irrigation system located in field conditions under different service pressures, through the determination of the Coefficient of Uniformity of Christiansen (CUC), Coefficient of Distribution Uniformity (CUD) and Statistical Uniformity Coefficient (Us). In the field, 4 randomly selected lateral lines were used and with the aid of a beaker and stop watch, the water volumes were measured in 4 thin-walled drippers in three repetitions in a time of 60 seconds, observing the 3 different service pressures (5.1, 10.2 and 15.3 microns). The mean values found for the Christiansen Uniformity Coefficient (CUC), Uniform Distribution Coefficient (CUD) and the Statistical Uniformity Coefficient (Us) are considered by the specialized literature to be excellent. However, in the service pressure of 5.1 mca, the uniformity of water distribution tends to be compromised. It is inferred, therefore, that the irrigation system is well-sized working, thus avoiding financial damages, regardless of the pressures of services in which it is operating.   Keywords: uniformity, micro-irrigation, manometric heights.


Author(s):  
J.N. Abedalrahman ◽  
R.J. Mansor ◽  
D.R. Abass

A field experiment was carried out in the field of the College of Agriculture / University of Wasit, located on longitude  45o   50o   33.5o   East and latitude 32o 29o 49.8o North, in Spring season of the agricultural season 2019, in order to estimate the water consumption of potato crop using SWRT technology and under the drip irrigation system. The experiment was designed according to Randomized Complete Block Design (RCBD) with three replications and four treatments that include of the SWRT treatment (the use of plastic films under the plant root area in an engineering style), and the treatment of vegetal fertilizer (using Petmos), organic fertilizer (sheep manure), and the control treatment . Potato tubers (Solanum tuberosum L.)  var. Burin was planted for spring season on 10/2/2019 at the soil depth of 5-10 cm. The highest reference water consumption for the potato crop during the season was calculated by Najeeb Kharufa, which was 663.03 mm. The highest actual water consumption for the potato crop during the season for the control treatment was 410.1 mm. The results showed increase in the values of the crop coefficient (Kc) in the stages of tubers formation and tubers filling stage as compared to the vegetative and ripening stages, ranged from 1.37-1.92 for the two stages of tubers formation and tubers filling. The SWRT treatment gave the highest water use efficiency during the season, was 3.46 kg m-3 .


Sign in / Sign up

Export Citation Format

Share Document