scholarly journals RP-HPLC Method Development and Validation for Simultaneous Estimation of Thymoquinone and Curcumin in Dosage form

Author(s):  
Prajakta Jagtap ◽  
Namrata Mahajan ◽  
Anjali Parte ◽  
Jeeja Pananchery ◽  
Ashish Jain

Aim: The aim of work is to develop and validate simple, specific, accurate, precise HPLC method for the estimation of Curcumin (CUR) and Thymoquinone (THQ) simultaneously in bulk and its formulation as per ICH guidelines for analytical method development and validation. Study Design: Developing RP-HPLC method using C-18 Inertsil column and optimization of variables for estimation of Thymoquinone and Curcumin in bulk and formulation. Place and Duration of Study: The present work was carried out at Shri D. D. Vispute College of Pharmacy and Research Center, Panvel in year 2021. Methodology: The RP-HPLC method was developed with an isocratic condition of mobile phase comprising acetonitrile and water in a ratio of (82:18) v/v, at a flow rate of 0.9 mL/minute over Inertsil ODS, 250× 4.6 mm, 5 µm column, at 30°C column oven temperature. Photodiode array at 256 nm was used for detection Results: Retention time for curcumin and thymoquinone was found to be 3.5 and 4.3 mins respectively. The method showed excellent linear response in concentration range of 4-18 µg/mland 10-45 µg/mlfor thymoquinone and curcuminrespectively with correlation coefficient (R2) values of0.999 for both. System precision and method precision studies were less than the maximum allowable limit percentage of relative standard deviation ≤ 2.0 i.e., 1.61 % and 1.62 % for curcumin and 0.47 % and 0.42 % for thymoquinone respectively. Mean % Recovery for both the drugs were within acceptance limits. The developed and validated HPLC method is simple, accurate, precise and suitable for analysis as all the results were within acceptance criteria. Conclusion: The developed RP-HPLC method at single wavelength was validated according to ICH guideline with respect to system suitability, specificity, linearity, accuracy, precision and robustness and can be used for routine quality monitoring of drug in pharmaceutical dosage form.

Author(s):  
Neha Desai ◽  
Munira Momin ◽  
Upasana Singh ◽  
Tabassum Khan ◽  
Atul Sherje

Objective: The present work was undertaken with an aim to develop and validate a rapid reverse-phase high-performance liquid chromatography (RP-HPLC) method for the estimation of curcumin and cyclosporine in the capsule dosage form. Methods: The RP-HPLC method for the simultaneous estimation of curcumin and cyclosporine was developed using Agilent (Infinity 1260) HPLC system and Eclipse XDB-C18 (4.6 x 150 mm i.d., 5µ) stationary phase. The optimized mobile phase comprised of acetonitrile: water: methanol (50: 10: 40 v/v/v) pumped at a flow rate of 0.5 ml/min. Separation of drugs was achieved in an isocratic mode and elution was monitored using PDA detector at 214 nm. The method was validated as per ICH-Q2R1 guidelines. Results: Retention time of the curcumin and cyclosporine were found to be 3.073 min and 6.373 min with the correlation coefficient (R2) of 0.9993 and 0.998 respectively. The response of curcumin and cyclosporine was found linear in the concentration range of 8-48 μg/ml and 4-24 μg/ml respectively. The percent recovery values were found in the range of 97-103% indicating satisfactory accuracy of the method. The percent relative standard deviation (% RSD) values for the precision study was less than 2 which suggest that the method is precise. Conclusion: The proposed method was found accurate, precise and specific for the determination of curcumin and cyclosporine in bulk as well as in capsule dosage form. Thus, the present method can be used for routine analysis and quality control of curcumin and cyclosporine in bulk and capsule dosage form.


Sign in / Sign up

Export Citation Format

Share Document