biomedical detection
Recently Published Documents


TOTAL DOCUMENTS

26
(FIVE YEARS 12)

H-INDEX

6
(FIVE YEARS 1)

PhotoniX ◽  
2021 ◽  
Vol 2 (1) ◽  
Author(s):  
Yan Peng ◽  
Jieli Huang ◽  
Jie Luo ◽  
Zhangfan Yang ◽  
Liping Wang ◽  
...  

AbstractTerahertz technology has broad application prospects in biomedical detection. However, the mixed characteristics of actual samples make the terahertz spectrum complex and difficult to distinguish, and there is no practical terahertz detection method for clinical medicine. Here, we propose a three-step one-way terahertz model, presenting a detailed flow analysis of terahertz technology in the biomedical detection of renal fibrosis as an example: 1) biomarker determination: screening disease biomarkers and establishing the terahertz spectrum and concentration gradient; 2) mixture interference removal: clearing the interfering signals in the mixture for the biomarker in the animal model and evaluating and retaining the effective characteristic peaks; and 3) individual difference removal: excluding individual interference differences and confirming the final effective terahertz parameters in the human sample. The root mean square error of our model is three orders of magnitude lower than that of the gold standard, with profound implications for the rapid, accurate and early detection of diseases.


2021 ◽  
Author(s):  
Yan Peng ◽  
Jieli Huang ◽  
Jie Luo ◽  
Zhangfan Yang ◽  
Liping Wang ◽  
...  

Abstract Terahertz technology has broad application prospects in biomedical detection. However, the mixed characteristics of actual samples make the terahertz spectrum complex and difficult to distinguish, and there is no practical terahertz detection method for medical clinics. Here, we propose a three-step one-way terahertz model, presenting a detailed flow analysis of terahertz technology in the biomedical detection of renal fibrosis as an example: 1) biomarker determination: screening disease biomarkers and establishing the terahertz spectrum and concentration gradient; 2) mixture interference removal: clearing the interfering signals in the mixture for the biomarker in the animal model and evaluating and retaining the effective characteristic peaks; and 3) individual difference removal: excluding individual interference differences and confirming the final effective terahertz parameters in the human sample. The root mean square error of our model is three orders of magnitude lower than that of the gold standard, with profound implications for the rapid, accurate and early detection of diseases.


2021 ◽  
Vol 41 (1) ◽  
pp. 0130001
Author(s):  
朱亦鸣 Zhu Yiming ◽  
施辰君 Shi Chenjun ◽  
吴旭 Wu Xu ◽  
彭滟 Peng Yan

Author(s):  
Astrid R. Concha ◽  
Claire M. Guest ◽  
Rob Harris ◽  
Thomas W. Pike ◽  
Alexandre Feugier ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document