standard map
Recently Published Documents


TOTAL DOCUMENTS

233
(FIVE YEARS 24)

H-INDEX

29
(FIVE YEARS 1)

Circulation ◽  
2021 ◽  
Vol 144 (Suppl_2) ◽  
Author(s):  
Yael Levy ◽  
Alice Hutin ◽  
Nicolas Polge ◽  
fanny lidouren ◽  
Matthias Kohlhauer ◽  
...  

Introduction: Extracorporeal cardiopulmonary resuscitation (E-CPR) is used for the treatment of refractory cardiac arrest but the optimal target to reach for mean arterial pressure (MAP) remains to be determined. Hypothesis: We hypothesized that MAP levels modify cerebral hemodynamics during E-CPR. Accordingly, we tested two MAP targets (65-75 vs 80-90 mmHg) in a porcine model of E-CPR. Methods: Pigs were anesthetized and instrumented for the evaluation of cerebral and systemic hemodynamics. They were submitted to 15 min of untreated ventricular fibrillation followed by 30 min of E-CPR. Electric attempts of defibrillation were then delivered until resumption of spontaneous circulation (ROSC). Extracorporeal circulation was initially set to an average flow of 40 ml/kg/min with a standardized volume expansion in both groups. The dose of epinephrine was set to reach either a standard or a high MAP target level (65-75 vs 80-90 mmHg, respectively). Animals were followed during 120 min after ROSC. Results: Six animals were included in both groups. After cardiac arrest, MAP was maintained at the expected level (Figure). During E-CPR, high MAP transiently improved carotid blood flow as compared to standard MAP. This blood flow progressively decreased after ROSC in high vs standard MAP, while intra-cranial pressure increased. Interestingly, this was associated with a significant decrease in cerebral oxygen consumption (26±8 vs 54±6 L O 2 /min/kg at 120 min after ROSC, respectively; p<0.01) (Figure). The pressure reactivity index (PRx), which is the correlation coefficient between arterial blood pressure and intracranial pressure, became positive in high MAP (0.47±0.02) vs standard MAP group (-0.16±0.10), demonstrating altered cerebral autoregulation with high MAP. Conclusion: Increasing MAP above 80 mmHg with epinephrine aggravates cerebral hemodynamics after E-CPR. Figure: Mean arterial pressure (MAP), cerebral blood flow and oxygen consumption (*, p<0.05)


Critical Care ◽  
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Yael Levy ◽  
Alice Hutin ◽  
Fanny Lidouren ◽  
Nicolas Polge ◽  
Rocio Fernandez ◽  
...  

Abstract Background Extracorporeal cardiopulmonary resuscitation (E-CPR) is used for the treatment of refractory cardiac arrest. However, the optimal target to reach for mean arterial pressure (MAP) remains to be determined. We hypothesized that MAP levels critically modify cerebral hemodynamics during E-CPR and tested two distinct targets (65–75 vs 80–90 mmHg) in a porcine model. Methods Pigs were submitted to 15 min of untreated ventricular fibrillation followed by 30 min of E-CPR. Defibrillations were then delivered until return of spontaneous circulation (ROSC). Extracorporeal circulation was initially set to an average flow of 40 ml/kg/min. The dose of epinephrine was set to reach a standard or a high MAP target level (65–75 vs 80–90 mmHg, respectively). Animals were followed during 120-min after ROSC. Results Six animals were included in both groups. During E-CPR, high MAP improved carotid blood flow as compared to standard MAP. After ROSC, this was conversely decreased in high versus standard MAP, while intra-cranial pressure was superior. The pressure reactivity index (PRx), which is the correlation coefficient between arterial blood pressure and intracranial pressure, also demonstrated inverted patterns of alteration according to MAP levels during E-CPR and after ROSC. In standard-MAP, PRx was transiently positive during E-CPR before returning to negative values after ROSC, demonstrating a reversible alteration of cerebral autoregulation during E-CPR. In high-MAP, PRx was negative during E-CPR but became sustainably positive after ROSC, demonstrating a prolonged alteration in cerebral autoregulation after ROSC. It was associated with a significant decrease in cerebral oxygen consumption in high- versus standard-MAP after ROSC. Conclusions During early E-CPR, MAP target above 80 mmHg is associated with higher carotid blood flow and improved cerebral autoregulation. This pattern is inverted after ROSC with a better hemodynamic status with standard versus high-MAP.


Author(s):  
Renato C. Calleja ◽  
Alessandra Celletti ◽  
Rafael de la Llave

Author(s):  
Matheus S. Palmero ◽  
Gabriel I. Díaz ◽  
Iberê L. Caldas ◽  
Igor M. Sokolov

2021 ◽  
Vol 11 (5) ◽  
pp. 2198
Author(s):  
Junwoo Jung ◽  
Jaesung Lim ◽  
Sungyeol Park ◽  
Haengik Kang ◽  
Seungbok Kwon

A frequency hopping orthogonal frequency division multiple access (FH-OFDMA) can provide low probability of detection (LPD) and anti-jamming capabilities to users against adversary detectors. To obtain an extreme LPD capability that cannot be provided by the basic symbol-by-symbol (SBS)-based FH pattern, we proposed two FH patterns, namely chaotic standard map (CSM) and cat map for FH-OFDMA systems. In our previous work, through analysis of complexity to regenerate the transmitted symbol sequence, at the point of adversary detectors, we found that the CSM had a lower probability of intercept than the cat map and SBS. It is possible when a detector already knows symbol and frame structures, and the detector has been synchronized to the FH-OFDMA system. Unlike the previous work, here, we analyze whether the CSM provides greater LPD capability than the cat map and SBS by detection probability using spectrum sensing technique. We analyze the detection probability of the CSM and provide detection probabilities of the cat map and SBS compared to the CSM. Based on our analysis of the detection probability and numerical results, it is evident that the CSM provides greater LPD capability than both the cat map and SBS-based FH-OFDMA systems.


Forma ◽  
2021 ◽  
Vol 36 (1) ◽  
pp. 15-24
Author(s):  
Yoshihiro Yamaguchi ◽  
Kiyotaka Tanikawa
Keyword(s):  

Complexity ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-23
Author(s):  
Yucheng Chen ◽  
Chunming Tang ◽  
Zongxiang Yi

In the past decades, considerable attention has been paid to the chaos-based image encryption schemes owing to their characteristics such as extreme sensitivity to initial conditions and parameters, pseudo-randomness, and unpredictability. However, some schemes have been proven to be insecure due to using a single chaotic system. To increase the security, this work proposes a novel image encryption scheme based on the piecewise linear chaotic map (PWLCM) and the standard map. To the best of our knowledge, it is the first chaos-based image encryption scheme combining the PWLCM with the standard map, which adopts permutation-diffusion structure. Unlike the traditional scrambling way, a hierarchical diffusion strategy, which not only changes the pixel position but also modifies the value, is employed in the permutation phase. The operation model of row-by-row and column-by-column is further used to enhance the efficiency in the diffusion process. Consequently, a good trade-off efficiency and security can be achieved. Furthermore, the numerical simulations and performance analyses illustrate that the proposed encryption scheme can be used in practical application scenarios requiring lightweight security.


Sign in / Sign up

Export Citation Format

Share Document