minimal luminal diameter
Recently Published Documents


TOTAL DOCUMENTS

17
(FIVE YEARS 4)

H-INDEX

4
(FIVE YEARS 0)

2022 ◽  
Vol 2022 ◽  
pp. 1-7
Author(s):  
Hengdao Liu ◽  
Hailong Tao ◽  
Xufei Han ◽  
Yang Lu ◽  
Xiaofei Xue ◽  
...  

Background. Drug-eluting stent (DES) plus drug-coated balloon (DCB) is a safe and effective treatment strategy for coronary artery bifurcation lesions, but there is no report about this strategy being used for left main (LM) bifurcation lesions. We aim to explore the efficacy and safety of DES plus DCB in the treatment of LM bifurcation lesions. Methods. A total of 100 patients diagnosed with LM bifurcation lesions by coronary angiography were retrospectively enrolled at our center from January 2018 to December 2019. They received either a two-stent strategy or a main branch (MB) stenting plus side branch (SB) DCB strategy and were accordingly divided into the 2-DES group and the DES + DCB group. Patients treated with DES + DCB were compared with a cohort of matched patients treated with a 2-DES strategy. Clinical data was collected and quantitative coronary analysis was performed. Results. For immediate postoperative angiography, though the two groups had no differences in the minimal luminal diameter (MLD) and luminal stenosis of MB, the DES + DCB group had significantly lower SB ostial MLD and a higher degree of residual lumen stenosis than the 2-DES group ( P < 0.05 ). At the time of follow-up, the SB ostial MLD of the DES + DCB group was higher than that of the 2-DES group, but lumen stenosis, late lumen loss (LLL), and LLL at the distal end of the left MB were all smaller than those of the 2-DES group ( P s < 0.05 ). Furthermore, the incidence of lumen restenosis and MACE between the two groups had no significance. Conclusion. The combination of DES and DCB is relatively safe and effective for the treatment of LM bifurcation lesions, and this strategy seems to have advantages in reducing LLL at the SB ostium.


Author(s):  
Takahisa Mori ◽  
Kazuhiro Yoshioka ◽  
Yuhei Tanno ◽  
Shigen Kasakura ◽  
Yuichi Miyazaki

Abstract Objectives Angiographic “slow flow” in the middle cerebral artery (MCA), caused by carotid stenosis, may be associated with high oxygen extraction fraction (OEF). If the MCA slow flow is associated with a reduced relative signal intensity (rSI) of the MCA on MR angiography, the reduced rSI may be associated with a high OEF. We investigated whether the MCA slow flow ipsilateral to carotid stenosis was associated with a high OEF and aimed to create a practical index to estimate the high OEF. Methods We included patients who underwent digital subtraction angiography (DSA) and MRA between 2015 and 2019 to evaluate carotid stenosis. MCA slow flow by image count using DSA, MCA rSI, minimal luminal diameter (MLD) of the carotid artery, carotid artery stenosis rate (CASr), and whole-brain OEF (wb-OEF) was evaluated. When MCA slow flow was associated with a high wb-OEF, the determinants of MCA slow flow were identified, and their association with high wb-OEF was evaluated. Results One hundred and twenty-seven patients met our inclusion criteria. Angiographic MCA slow flow was associated with high wb-OEF. We identified MCA rSI and MLD as determinants of angiographic MCA slow flow. The upper limits of MCA rSI and MLD for angiographic MCA slow flow were 0.89 and 1.06 mm, respectively. The wb-OEF was higher in patients with an MCA rSI ≤ 0.89 and ipsilateral MLD ≤ 1.06 mm than patients without this combination. Conclusions The combination of reduced MCA rSI and ipsilateral narrow MLD is a straightforward index of high wb-OEF. Key Points • The whole-brain OEF in patients with angiographic slow flow in the MCA ipsilateral to high-grade carotid stenosis was higher than in patients without it. • Independent determinants of MCA slow flow were MCA relative signal intensity (rSI) on MRA or minimal luminal diameter (MLD) of the carotid stenosis. • The wb-OEF was higher in patients with an MCA rSI ≤ 0.89 and ipsilateral MLD ≤ 1.06 mm than patients without this combination.


Angiology ◽  
2021 ◽  
pp. 000331972110155
Author(s):  
Woong Chol Kang ◽  
Sang Min Park ◽  
Albert Youngwoo Jang ◽  
Pyung Chun Oh ◽  
Eun-Seok Shin ◽  
...  

We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was −0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and % diameter stenosis (DS ) <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.


Angiology ◽  
2021 ◽  
pp. 000331972199617
Author(s):  
Monica Verdoia ◽  
Rocco Gioscia ◽  
Matteo Nardin ◽  
Orazio Viola ◽  
Marta Francesca Brancati ◽  
...  

Aim: Instantaneous wave-free ratio (iFR) has emerged as the strategy of choice for the assessment of intermediate coronary lesions. The impact of preprocedural β-blockers therapy on the iFR was the aim of this study. Methods: We included patients undergoing functional assessment of intermediate (40%-70%) coronary lesions in 2 centers. The iFR measurement was performed by pressure-recording guidewire and calculated at the core laboratory using the manufacturers’ dedicated software. Minimal luminal diameter, reference diameter, percent diameter stenosis, and length of the lesion were measured. Positive iFR was considered for values <0.90. Results: We included 197 patients undergoing functional evaluation of 223 coronary lesions. Patients on β-blockers (69%) had more frequently hypertension ( P = .05); previous myocardial infarction ( P = .01); therapy with clopidogrel ( P = .02), statins, and aspirin; and acute coronary syndrome at presentation ( P < .001, respectively). Mean iFR values were slightly higher in patients on β-blockers (0.94 ± 0.06 vs 0.92 ± 0.06, P = .11). The rate of positive iFR was significantly lower with β-blockers (14.9% vs 27.5%, P = .04). On multivariate analysis, β-blockers use was a predictor of the significance of coronary stenoses (odds ratio [OR] = 0.48; 95% CI = 0.23-0.98; P = .05) together with lesion length (OR = 1.04; 95% CI = 1.01-1.07; P = .007). Conclusion: Among patients undergoing iFR, preprocedural β-blockers are associated with higher absolute values and a lower rate of positive iFR.


2018 ◽  
Vol 19 (6) ◽  
pp. 548-554 ◽  
Author(s):  
Lukas K Kairaitis ◽  
James P Collett ◽  
Jan Swinnen

Introduction: The optimal method for vascular access surveillance is largely unknown. A previous case–control study suggested a simplified anatomical measure obtained by Doppler ultrasound—the narrowest segment of the circuit or “minimal luminal diameter” may identify patients with a dysfunctional radiocephalic arteriovenous fistula. The relationship between minimal luminal diameter and access flow (Qa) in the radiocephalic arteriovenous fistula has not previously been studied. Methods: Patients undergoing Doppler ultrasound of a radiocephalic arteriovenous fistula over an 8-month period were identified retrospectively. Minimal luminal diameter was identified and demographic and clinical data were collected. Qa was estimated by Doppler estimation of brachial artery flow. The relationship between minimal luminal diameter and Qa was examined by correlation and using different levels of minimal luminal diameter as a simplified measure to detect or exclude low Qa (<600 mL/min). Results: A total of 81 Doppler ultrasound scans were performed. In all, 26 scans demonstrated brachial artery flow <600 mL/min. Simple logistic regression indicated a weak statistical relationship between the minimal luminal diameter and Qa (R2 = 0.27, p < 0.01). Minimal luminal diameter performed poorly as a marker of low Qa with low specificity, however, showed high negative predictive value for ruling out low Qa at a minimal luminal diameter of 3.2 mm or higher (94%). Qa estimated by brachial artery flow correlated well with Qa estimated by indicator dilution (R2 = 0.83, p < 0.01) without significant mean difference or proportional bias. Conclusion: Minimal luminal diameter correlates weakly with Qa. Low minimal luminal diameter values should not be used in isolation to determine low Qa for a radiocephalic arteriovenous fistula. Conversely, minimal luminal diameter >3.2 mm largely excludes a low-flow radiocephalic arteriovenous fistula in this cohort. Brachial artery flow is a reasonable measure of Qa in comparison with indicator dilution.


2007 ◽  
Vol 69 (2) ◽  
pp. 181-188 ◽  
Author(s):  
Marco A. Costa ◽  
Manel Sabaté ◽  
Dominick J. Angiolillo ◽  
Paula Hu ◽  
Pilar Jimenez-Quevedo ◽  
...  

2000 ◽  
Vol 36 (5) ◽  
pp. 1536-1541 ◽  
Author(s):  
Manel Sabaté ◽  
Marco A Costa ◽  
Ken Kozuma ◽  
I.Patrick Kay ◽  
Connie J van der Wiel ◽  
...  

2000 ◽  
Vol 139 (3) ◽  
pp. 0482-0490
Author(s):  
Bj[oslash]rn J. J[oslash]rgensen ◽  
Svein J. Simonsen ◽  
Knut J. Endresen ◽  
Kolbj[oslash]rn J. Forfang ◽  
Thore J. Egeland ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document