transient voltage
Recently Published Documents


TOTAL DOCUMENTS

508
(FIVE YEARS 115)

H-INDEX

21
(FIVE YEARS 5)

2022 ◽  
Vol 8 ◽  
pp. 487-492
Author(s):  
Shuanbao Niu ◽  
Zhe Zhang ◽  
Xianbo Ke ◽  
Gang Zhang ◽  
Chao Huo ◽  
...  

IEEE Access ◽  
2022 ◽  
pp. 1-1
Author(s):  
Jiann-Jong Chen ◽  
Yuh-Shyan Hwang ◽  
Wei-Ming Jiang ◽  
Chien-Hung Lai ◽  
Joshua Ku

Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4863
Author(s):  
Ziwei Zhang ◽  
Dengwei Ding ◽  
Liang He ◽  
Weidong Liu ◽  
Cuifen Bai ◽  
...  

Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.


2021 ◽  
Vol 36 (6) ◽  
pp. 670-675
Author(s):  
Sung-Yeon Kim ◽  
Jeong-Su Park ◽  
Wang-Sang Lee

In this paper, an indirect lightning-induced transient protection circuit for avionics system is proposed, and its effectiveness is verified. The proposed circuit consists of a metal oxide varistor (MOV), a transient voltage suppression (TVS) diode, and a resistor. Compared with the conventional circuits (MOV or TVS diode), the improved noise suppression of the proposed circuit against indirect lightning strikes are experimentally verified in accordance with radio technical commission for aeronautics (RTCA) DO-160G Sec. 22. The highest attenuation levels of indirect lightning strike WF5A reference voltage and current signals are approximately 91.0% and approximately 98.4% for the input lightning signals, respectively.


Sign in / Sign up

Export Citation Format

Share Document