osteosynthetic material
Recently Published Documents


TOTAL DOCUMENTS

7
(FIVE YEARS 2)

H-INDEX

2
(FIVE YEARS 0)

2022 ◽  
Vol 11 (2) ◽  
pp. 362
Author(s):  
Roman Madeja ◽  
Jana Pometlová ◽  
Roman Brzóska ◽  
Jiří Voves ◽  
Lubor Bialy ◽  
...  

Data on the effectiveness of arthroscopic arthrolysis and extraction of osteosynthetic material after osteosynthesis of the proximal humerus in patients with persisting problems are rare and insufficient. In this study, we performed arthroscopic arthrolysis and extraction of fixation screws, and, where protruding, extraction of the nail in 34 patients with problems persisting 12 months after osteosynthesis of the proximal humerus using an intramedullary nail. The effectiveness of the treatment was assessed using the Constant–Murley shoulder score and forward flexion difference between the treated arm and the contralateral one. A median increase of 16 points in CMS score and 30 degrees reduction in the arm forward flexion difference was recorded 12 months after the arthroscopy. The improvement was significantly higher in the patient group with intramedullary nail extraction (however, this group had worse pre-operative values and the screw was only extracted where likely to cause problems). The median time to heal was 11 weeks; no serious peri- or post-procedural complications occurred. Mini-invasive arthroscopic arthrolysis combined with extraction of osteosynthetic material proved to be a safe and effective method for treatment of patients after osteosynthesis of the proximal humerus using an intramedullary nail with persisting pain and/or mobility limitation.


2021 ◽  
Vol 10 (16) ◽  
pp. 3604
Author(s):  
Maciej Sikora ◽  
Maciej Chęciński ◽  
Zuzanna Nowak ◽  
Kamila Chęcińska ◽  
Tomasz Olszowski ◽  
...  

Introduction: Fixing fractures of the base and neck of mandibular condyles is demanding due to the difficulties in surgical access and the various shapes of bone fragments. Classic fixation techniques assume the use of straight mini-plates, utilized for other craniofacial bone fractures. Three dimensional mini-plates may provide a reasonable alternative due to their ease of use and steadily improved mechanical properties. The multitude of different shapes of 3D mini-plates proves the need for their evaluation. Aim: This paper aims to summarize the clinical trials regarding the use of various types of 3D condylar mini-plates in terms of need for reoperation and the incidence of loosening and damage to the osteosynthetic material. Materials and Methods: A systematic review was conducted in accordance with PICOS criteria and PRISMA protocol. The risk of bias was assessed using ROBINS-I and RoB 2 Cochrane protocols. The obtained data series was analyzed for correlations (Pearson’s r) respecting statistical significance (Student’s t-test p > 0.05) and visualized using OriginLab. Results: 13 clinical trials with low overall risk of bias regarding 6 shapes of 3D mini-plates were included in the synthesis. The number of reoperations correlates with the number of fixations (r = 0.53; p = 0.015) and the total number of screw holes in the mini-plate (r = −0.45; p = 0.006). There is a strong correlation between the number of loosened osteosynthetic screws and the total number of fractures treated with 3D mini-plates (r = 0.79; p = 0.001 for each study and r = 0.99; p = 0.015 for each mini-plate shape). A correlation between the percentage of lost screws and the number of distal screw holes is weak regarding individual studies (r = −0.27; p = 0.000) and strong regarding individual mini-plate shape (r = −0.82; p = 0.001). Three cases of 3D mini-plate fractures are noted, which account for 0.7% of all analyzed fixation cases. Discussion: The reasons for reoperations indicated by the authors of the analyzed articles were: mispositioning of the bone fragments, lack of bone fragment union, secondary dislocation, and hematoma. The known screw loosening factors were poor bone quality, bilateral condylar fractures, difficulties in the correct positioning of the osteosynthetic material due to the limitations of the surgical approach, fracture line pattern, including the presence of intermediate fragments, and mechanical overload. Fractures of the straight mini-plates fixing the mandibular condyles amounts for up to 16% of cases in the reference articles. Conclusions: There is no convincing data that the number of reoperations depends on the type of 3D mini-plate used. The frequency of osteosynthetic screw loosening does not seem to depend on the 3D mini-plate’s shape. Clinical fractures of 3D mini-plates are extremely rare.


2005 ◽  
Vol 48 (1) ◽  
pp. 49-52 ◽  
Author(s):  
Petr Habal ◽  
Václav Málek ◽  
Josef Novotný

The authors present a rare and unusual case of complication, migration of osteosynthetic material for stabilization, titanium rod, which was used for stabilization of comminutive fracture of the first lumbar vertebra. This rod migrated from the retroperitoneal space to the pleural cavity. The removal of this rod was carried out by videothoracoscopy.


1986 ◽  
Vol 81 (3-4) ◽  
pp. 118-124 ◽  
Author(s):  
F. Lesoin ◽  
M. Rousseaux ◽  
N. Bouasakao ◽  
L. Villette ◽  
C. E. Thomas ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document