human basophil
Recently Published Documents


TOTAL DOCUMENTS

162
(FIVE YEARS 3)

H-INDEX

31
(FIVE YEARS 0)

2021 ◽  
Vol 11 (40) ◽  
pp. 172-173
Author(s):  
Chantal Wälchli ◽  
Stephan Baumgartner

Background: Inhibition of human basophil activation by highly diluted histamine was reported to be a reliable experimental model to examine biological effects of high dilutions. However, independent replications did not always yield concordant results. Aims: We aimed at performing an independent replication of a former study [1] using rigorously controlled experimental conditions to minimise confounding factors. Materials and Methods: In 20 independent experiments, human basophils were treated with highly diluted histamine (15cH, 16cH, corresponding to 10-30-10-32 M) prior to activation by fMLP (formyl-methionyl-leucyl-phenylalanine peptide). Controls were treated with analogously diluted water (15cH, 16cH). The dilutions were prepared freshly for each experiment in deionised water by successive steps of centesimal dilution and agitation (10 s vortex at high speed). Highly diluted samples were blinded and randomised. All samples were set in triplicates. Activated basophils were determined by flow cytometry using anti-CD203c. 20 independent systematic negative control (SNC) experiments were carried out to investigate possible systematic errors. Results: No difference in basophil activation was observed between the highly diluted histamine samples and the highly diluted water controls. There was no evidence for a blood donor specificity of the results. The SNC experiments demonstrated the stability of the test system. Experimental variability within and between experiments was slightly reduced for the highly diluted histamine samples. Discussion: This study was designed as an independent reproduction of a former study [1]. Though we strictly adopted the experimental procedure described in [1], our results do not confirm the large inhibitory effects observed for histamine 15cH and 16cH. This lack of reproducibility might be due to minor differences in the experimental design, such as blinding and randomising of the samples, which we chose to perform in order to reduce the possibility of artifacts but was omitted in the former study. Conclusions: Laboratory independent replication of homeopathic basic research experiments is still a challenge. Assuming that the results formerly obtained with this model were not due to systematic errors, the quest identifying the crucial factors for successful reproducibility is open for future research. Keywords: Human basophils; histamine; high dilutions; flow cytometry Reference: [1] Sainte-Laudy J, Belon P. Improvement of flow cytometric analysis of basophil activation inhibition by high histamine dilutions. A novel basophil specific marker: CD 203c. Homeopathy. 2006;95:3-8.


2017 ◽  
Vol 5 (4) ◽  
pp. 386-399 ◽  
Author(s):  
Danh C. Do ◽  
Shuang Yang ◽  
Xu Yao ◽  
Robert G. Hamilton ◽  
John T. Schroeder ◽  
...  

2017 ◽  
Vol 139 (2) ◽  
pp. AB167 ◽  
Author(s):  
Danh C. Do ◽  
Shuang Yang ◽  
Robert G. Hamilton ◽  
John T. Schroeder ◽  
Hui Zhang ◽  
...  

2016 ◽  
Vol 65 (4) ◽  
pp. 466-468 ◽  
Author(s):  
Tsukasa Ugajin ◽  
Sayaka Shibama ◽  
Keigo Nishida ◽  
Hiroo Yokozeki

2016 ◽  
Vol 4 (3) ◽  
pp. 289-299 ◽  
Author(s):  
Lydie Cassard ◽  
Ana Inés Lalanne ◽  
Peggy Garault ◽  
Aurélie Cotillard ◽  
Christian Chervaux ◽  
...  

Allergy ◽  
2016 ◽  
Vol 71 (9) ◽  
pp. 1264-1273 ◽  
Author(s):  
S. Mommert ◽  
S. Kleiner ◽  
M. Gehring ◽  
B. Eiz-Vesper ◽  
H. Stark ◽  
...  

2015 ◽  
Vol 64 ◽  
pp. S80-S82 ◽  
Author(s):  
Yusuke Tanaka ◽  
Masao Yamaguchi ◽  
Maho Suzukawa ◽  
Hidenori Arai ◽  
Hiroyuki Nagase ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document