axial behavior
Recently Published Documents


TOTAL DOCUMENTS

126
(FIVE YEARS 43)

H-INDEX

11
(FIVE YEARS 3)

Author(s):  
Zhibin Li ◽  
Enrique del Rey Castillo ◽  
Richard S. Henry ◽  
Andrew Thompson
Keyword(s):  

Structures ◽  
2021 ◽  
Vol 34 ◽  
pp. 2708-2720
Author(s):  
Rong Su ◽  
Xian Li ◽  
Tao Zhong ◽  
Tao Zhou
Keyword(s):  

Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1434
Author(s):  
Muhammmad Faisal Javed ◽  
Haris Rafiq ◽  
Mohsin Ali Khan ◽  
Fahid Aslam ◽  
Muhammad Ali Musarat ◽  
...  

This experimental study presents concrete-filled double-skin tubular columns and demonstrates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10% strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004).


2021 ◽  
pp. 136943322110339
Author(s):  
Jiongfeng Liang ◽  
Siqi Lin ◽  
Mizan Ahmed

The behavior of fiber-reinforced polymer (FRP)–confined recycled aggregate concrete-filled steel tube (RACFT) columns is barely studied. Especially, that of slender specimens has not been investigated so far. In this article, an experimental test of FRP-confined RACFT slender square columns was conducted to study the influences of recycled aggregate (RA) replacement ratios, FRP thicknesses, and wrapping schemes on their axial behavior. Results in this article suggest that the RA replacement ratio barely affects the initial stiffness of load-deflection curves of specimens. Moreover, the specimen with a higher RA replacement ratio has a lower axial stress but larger strain at the peak point. The external FRP jackets (either partial or full wrap) can effectively improve the performance of axially loaded RACFT columns, and the improvement of ductility due to the increase of the FRP thickness is more significant than that of axial compressive strength. Additionally, it was found that the axial strength and ultimate axial strain decrease with increasing slenderness ratios. Furthermore, the influences of slenderness ratios on the behavior of such columns are more significant for the column with a larger length-to-width ratio. Finally, a design model for FRP-confined RACFT slender square columns is developed, which can predict the results of the present test accurately.


Sign in / Sign up

Export Citation Format

Share Document